Juliana Coatrini Soares
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juliana Coatrini Soares has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Andrey Coatrini Soares
Embrapa Instrumentação
15 shared publications - Osvaldo Novais Oliveira
Sao Carlos Institute of Physics University of Sao Paulo Sao Carlos Sao Paulo Brazil
12 shared publications - Matias Eliseo Melendez
Molecular Oncology Research Center, Barretos Cancer Hospital, Barretos, Brazil
6 shared publications - Rui Luis Reis
Barretos Cancer Hospital
6 shared publications - Valquiria Cruz Rodrigues
São Carlos Institute of Physics , University of São Paulo , 13566-590 São Carlos , Brazil
6 shared publications - André Lopes Carvalho
Early Detection, Prevention & Infections Branch International Agency for Research on Cancer Lyon France
5 shared publications
Latest Publications
- Open Access
- 3 April 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (15) , 6581-6590
Microfluidic Electronic Tongue Made with Nanostructured Films of Proteins from Renewable Sources to Detect H5N1 Antibodies from Avian Influenza Virus
- 3 April 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (15) , 6581-6590
Open AccessMicrofluidic Electronic Tongue Made with Nanostructured Films of Proteins from Renewable Sources to Detect H5N1 Antibodies from Avian Influenza Virus
- Open Access
- 17 February 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (2) , 1407-1418
Using Machine Learning and Optical Microscopy Image Analysis of Immunosensors Made on Plasmonic Substrates: Application to Detect the SARS-CoV-2 Virus
In this article, we introduce a diagnostic platform comprising an optical microscopy image analysis system coupled with machine learning. Its efficacy is demonstrated in detecting SARS-CoV-2 virus particles at concentrations as low as 1 PFU (plaque-forming unit) per milliliter by processing images from an immunosensor on a plasmonic substrate. This high performance was achieved by classifying images with the support vector machine (SVM) algorithm and the MobileNetV3_small convolutional neural network (CNN) model, which attained an accuracy of 91.6% and a specificity denoted by an F1 score of 96.9% for the negative class. Notably, this approach enabled the detection of SARS-CoV-2 concentrations 1000 times lower than the limit of detection achieved with localized surface plasmon resonance (LSPR) sensing using the same immunosensors. It is also significant that a binary classification between control and positive classes using the MobileNetV3_small model and the random forest algorithm achieved an accuracy of 96.5% for SARS-CoV-2 concentrations down to 1 PFU/mL. At such low concentrations, straightforward screening of newly infected patients may be feasible. In supporting experiments, we verified that texture was the main contributor to the distinguishability of images taken at different SARS-CoV-2 concentrations, indicating that the combination of ML and image analysis may be applied to any biosensor whose detection mechanism is based on adsorption.
- 17 February 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (2) , 1407-1418
Open AccessUsing Machine Learning and Optical Microscopy Image Analysis of Immunosensors Made on Plasmonic Substrates: Application to Detect the SARS-CoV-2 Virus
In this article, we introduce a diagnostic platform comprising an optical microscopy image analysis system coupled with machine learning. Its efficacy is demonstrated in detecting SARS-CoV-2 virus particles at concentrations as low as 1 PFU (plaque-forming unit) per milliliter by processing images from an immunosensor on a plasmonic substrate. This high performance was achieved by classifying images with the support vector machine (SVM) algorithm and the MobileNetV3_small convolutional neural network (CNN) model, which attained an accuracy of 91.6% and a specificity denoted by an F1 score of 96.9% for the negative class. Notably, this approach enabled the detection of SARS-CoV-2 concentrations 1000 times lower than the limit of detection achieved with localized surface plasmon resonance (LSPR) sensing using the same immunosensors. It is also significant that a binary classification between control and positive classes using the MobileNetV3_small model and the random forest algorithm achieved an accuracy of 96.5% for SARS-CoV-2 concentrations down to 1 PFU/mL. At such low concentrations, straightforward screening of newly infected patients may be feasible. In supporting experiments, we verified that texture was the main contributor to the distinguishability of images taken at different SARS-CoV-2 concentrations, indicating that the combination of ML and image analysis may be applied to any biosensor whose detection mechanism is based on adsorption.
- 2 April 2024
- Published by Wiley in Microscopy Research and Technique
- Vol. 87 (8) , 1933-1954
Virus adsorbent systems based on Amazon holocellulose and nanomaterials
The environment preservation has been an important motivation to find alternative, functional, and biodegradable materials to replace polluting petrochemicals. The production of nonbiodegradable face masks increased the concentration of microplastics in the environment, highlighting the need for sustainable alternatives, such as the use of local by‐products to create efficient and eco‐friendly filtering materials. Furthermore, the use of smart materials can reduce the risk of contagion and virus transmission, especially in the face of possible mutations. The development of novel materials is necessary to ensure less risk of contagion and virus transmission, as well as to preserve the environment. Taking these factors into account, 16 systems were developed with different combinations of precursor materials (holocellulose, polyaniline [ES‐PANI], graphene oxide [GO], silver nanoparticles [AgNPs], and activated carbon [AC]). Adsorption tests of the spike protein showed that the systems containing GO and AC were the most efficient in the adsorption process. Similarly, plate tests conducted using the VSV‐IN strain cultured in HepG2 cells showed that the system containing all phases showed the greatest reduction in viral titer method. In agreement, the biocompatibility tests showed that the compounds extracted from the systems showed low cytotoxicity or no significant cytotoxic effect in human fibroblasts. As a result, the adsorption tests of the spike protein, viral titration, and biocompatibility tests showed that systems labeled as I and J were the most efficient. In this context, the present research has significantly contributed to the technological development of antiviral systems, with improved properties and increased adsorption efficiency, reducing the viral titer and contributing efficiently to public health. In this way, these alternative materials could be employed in sensors and devices for filtering and sanitization, thus assisting in mitigating the transmission of viruses and bacteria.Research Highlights: Sixteen virus adsorbent systems were developed with different combinations of precursor materials (holocellulose, polyaniline (ES‐PANI), graphene oxide (GO), silver nanoparticles (AgNPs), and activated carbon (AC)). The system that included all of the nanocomposites holocellulose, PANI, GO, AgNPs, and AC showed the greatest reduction in viral titration. The biocompatibility tests revealed that all systems caused only mild or moderate cytotoxicity toward human fibroblasts.
- 2 April 2024
- Published by Wiley in Microscopy Research and Technique
- Vol. 87 (8) , 1933-1954
Virus adsorbent systems based on Amazon holocellulose and nanomaterials
The environment preservation has been an important motivation to find alternative, functional, and biodegradable materials to replace polluting petrochemicals. The production of nonbiodegradable face masks increased the concentration of microplastics in the environment, highlighting the need for sustainable alternatives, such as the use of local by‐products to create efficient and eco‐friendly filtering materials. Furthermore, the use of smart materials can reduce the risk of contagion and virus transmission, especially in the face of possible mutations. The development of novel materials is necessary to ensure less risk of contagion and virus transmission, as well as to preserve the environment. Taking these factors into account, 16 systems were developed with different combinations of precursor materials (holocellulose, polyaniline [ES‐PANI], graphene oxide [GO], silver nanoparticles [AgNPs], and activated carbon [AC]). Adsorption tests of the spike protein showed that the systems containing GO and AC were the most efficient in the adsorption process. Similarly, plate tests conducted using the VSV‐IN strain cultured in HepG2 cells showed that the system containing all phases showed the greatest reduction in viral titer method. In agreement, the biocompatibility tests showed that the compounds extracted from the systems showed low cytotoxicity or no significant cytotoxic effect in human fibroblasts. As a result, the adsorption tests of the spike protein, viral titration, and biocompatibility tests showed that systems labeled as I and J were the most efficient. In this context, the present research has significantly contributed to the technological development of antiviral systems, with improved properties and increased adsorption efficiency, reducing the viral titer and contributing efficiently to public health. In this way, these alternative materials could be employed in sensors and devices for filtering and sanitization, thus assisting in mitigating the transmission of viruses and bacteria.Research Highlights: Sixteen virus adsorbent systems were developed with different combinations of precursor materials (holocellulose, polyaniline (ES‐PANI), graphene oxide (GO), silver nanoparticles (AgNPs), and activated carbon (AC)). The system that included all of the nanocomposites holocellulose, PANI, GO, AgNPs, and AC showed the greatest reduction in viral titration. The biocompatibility tests revealed that all systems caused only mild or moderate cytotoxicity toward human fibroblasts.
- Open Access
- 4 April 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (15) , 13721-13732
Nanoarchitectonic E-Tongue of Electrospun Zein/Curcumin Carbon Dots for Detecting Staphylococcus aureus in Milk
- 4 April 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (15) , 13721-13732
Open AccessNanoarchitectonic E-Tongue of Electrospun Zein/Curcumin Carbon Dots for Detecting Staphylococcus aureus in Milk
- 24 June 2021
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 5 (15) , 5658-5670
Detection of a SARS-CoV-2 sequence with genosensors using data analysis based on information visualization and machine learning techniques
First genosensor for SARS-CoV-2 where multimodal detection principles can be employed, including image analysis based on machine learning.
- 24 June 2021
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 5 (15) , 5658-5670
Detection of a SARS-CoV-2 sequence with genosensors using data analysis based on information visualization and machine learning techniques
First genosensor for SARS-CoV-2 where multimodal detection principles can be employed, including image analysis based on machine learning.
- Open Access
- 14 December 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Detection of a SARS-CoV-2 Sequence with Genosensors Using Data Analysis Based on Information Visualization and Machine Learning Techniques
We report on genosensors to detect an ssDNA sequence from the SARS-CoV-2 genome, which mimics the GU280 gp10 gene (coding the viral nucleocapsid phosphoprotein), using four distinct principles of detection and treating the data with information visualization and machine learning techniques. Genosensors were fabricated on either gold (Au) interdigitated electrodes for electrical and electrochemical measurements or on Au nanoparticles on a glass slide for optical measurements. They contained a matrix of 11-mercaptoundecanoic acid (11-MUA) self-assembled monolayer (SAM) onto which a layer of capture probe (cpDNA) sequence was immobilized. Detection was performed using electrical and electrochemical impedance spectroscopies and localized surface plasmon resonance (LSPR). The highest sensitivity was reached with impedance spectroscopy, including using a low-cost (US$ 100) homemade impedance analyzer. Complementary ssDNA sequences were detected with a detection limit of 0.5 aM (0.3 copy/μL). This performance may be attributed to the high sensitivity of the electrical impedance technique combined with an appropriate arrangement of the sequences on the electrodes and hybridization between the complementary sequences, as inferred from polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). The selectivity of the genosensor was confirmed by plotting the impedance spectroscopy data with a multidimensional projection technique (Interactive Document Mapping, IDMAP), where a clear separation was observed among the samples of the complementary DNA sequence at various concentrations and from buffer samples containing a non-complementary sequence and other DNA biomarkers. The diagnosis of SARS-CoV-2 mimicking sequences was also achieved with machine learning techniques applied to scanning electron microscope images taken from genosensors exposed to distinct concentrations of the complementary ssDNA sequences. In summary, the genosensors proposed here are promising for detecting SARS-CoV-2 genetic material (RNA) in biological fluids in point-of-care settings.
- 14 December 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDetection of a SARS-CoV-2 Sequence with Genosensors Using Data Analysis Based on Information Visualization and Machine Learning Techniques
We report on genosensors to detect an ssDNA sequence from the SARS-CoV-2 genome, which mimics the GU280 gp10 gene (coding the viral nucleocapsid phosphoprotein), using four distinct principles of detection and treating the data with information visualization and machine learning techniques. Genosensors were fabricated on either gold (Au) interdigitated electrodes for electrical and electrochemical measurements or on Au nanoparticles on a glass slide for optical measurements. They contained a matrix of 11-mercaptoundecanoic acid (11-MUA) self-assembled monolayer (SAM) onto which a layer of capture probe (cpDNA) sequence was immobilized. Detection was performed using electrical and electrochemical impedance spectroscopies and localized surface plasmon resonance (LSPR). The highest sensitivity was reached with impedance spectroscopy, including using a low-cost (US$ 100) homemade impedance analyzer. Complementary ssDNA sequences were detected with a detection limit of 0.5 aM (0.3 copy/μL). This performance may be attributed to the high sensitivity of the electrical impedance technique combined with an appropriate arrangement of the sequences on the electrodes and hybridization between the complementary sequences, as inferred from polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). The selectivity of the genosensor was confirmed by plotting the impedance spectroscopy data with a multidimensional projection technique (Interactive Document Mapping, IDMAP), where a clear separation was observed among the samples of the complementary DNA sequence at various concentrations and from buffer samples containing a non-complementary sequence and other DNA biomarkers. The diagnosis of SARS-CoV-2 mimicking sequences was also achieved with machine learning techniques applied to scanning electron microscope images taken from genosensors exposed to distinct concentrations of the complementary ssDNA sequences. In summary, the genosensors proposed here are promising for detecting SARS-CoV-2 genetic material (RNA) in biological fluids in point-of-care settings.
- 8 September 2020
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 4 (11) , 3258-3266
Detection of HPV16 in cell lines deriving from cervical and head and neck cancer using a genosensor made with a DNA probe on a layer-by-layer matrix
Detection of human papillomavirus 16 (HPV16) is essential for the diagnosis of cervix and head and neck cancer, which has prompted the development of biosensors to replace the sophisticated molecular techniques. In this paper, we employ a genosensor made with a HPV16 DNA probe (cpHPV16) immobilized on a layer-by-layer (LbL) film of chitosan and carbon nanotubes to detect a complementary sequence HPV16 oligo (ssHPV16). In addition to employing impedance spectroscopy, which has already been used in the literature, we detect ssHPV16 in buffer samples and in cancer cell line samples with UV-vis. spectroscopy. The limit of detection was 18.5 pmol L−1 in impedance spectroscopy measurements and 10.9 pmol L−1 in UV-vis measurements. Distinction of the various ssHPV16 concentrations and of the cancer cell line samples CasKi, SiHa, UMSCC-47, UM-SCC104 and 93-VU147T with both electrical and optical data could be made with the multidimensional projection technique referred to as interactive document mapping (IDMAP), with which we could confirm the absence of false positives by testing cell lines that did not contain ssHPV16 (JHU12, JHU13 and JHU28). The hybridization between cpHPV16 and ssHPV16 responsible for the biosensing was verified with polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS), while the concentration dependence could be modeled with a double Freundlich function. The use of optical absorbance measurements to detect ssHPV16 is promising toward a simple colorimetric detection.
- 8 September 2020
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 4 (11) , 3258-3266
Detection of HPV16 in cell lines deriving from cervical and head and neck cancer using a genosensor made with a DNA probe on a layer-by-layer matrix
Detection of human papillomavirus 16 (HPV16) is essential for the diagnosis of cervix and head and neck cancer, which has prompted the development of biosensors to replace the sophisticated molecular techniques. In this paper, we employ a genosensor made with a HPV16 DNA probe (cpHPV16) immobilized on a layer-by-layer (LbL) film of chitosan and carbon nanotubes to detect a complementary sequence HPV16 oligo (ssHPV16). In addition to employing impedance spectroscopy, which has already been used in the literature, we detect ssHPV16 in buffer samples and in cancer cell line samples with UV-vis. spectroscopy. The limit of detection was 18.5 pmol L−1 in impedance spectroscopy measurements and 10.9 pmol L−1 in UV-vis measurements. Distinction of the various ssHPV16 concentrations and of the cancer cell line samples CasKi, SiHa, UMSCC-47, UM-SCC104 and 93-VU147T with both electrical and optical data could be made with the multidimensional projection technique referred to as interactive document mapping (IDMAP), with which we could confirm the absence of false positives by testing cell lines that did not contain ssHPV16 (JHU12, JHU13 and JHU28). The hybridization between cpHPV16 and ssHPV16 responsible for the biosensing was verified with polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS), while the concentration dependence could be modeled with a double Freundlich function. The use of optical absorbance measurements to detect ssHPV16 is promising toward a simple colorimetric detection.
- 6 August 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (18) , 6014-6023
Controlled molecular architectures in microfluidic immunosensors for detecting Staphylococcus aureus
Detection of pathogenic microorganisms is essential for food quality control and diagnosis of various diseases, which is currently performed with high-cost, sophisticated methods. In this paper, we report on a low-cost detection method based on impedance spectroscopy to detect Staphylococcus aureus (S. aureus). The immunosensors were made with microfluidic devices made of interdigitated electrodes coated with layer-by-layer (LbL) films of chitosan and chondroitin sulfate, on which a layer of anti-S. aureus antibodies was adsorbed. The limit of detection was 2.83 CFU mL−1 with a limit of quantification of 9.42 CFU mL−1 for immunosensors with 10-bilayer LbL films. This level of sensitivity is sufficient to detect traces of bacteria that cause mastitis in milk, which we have confirmed by distinguishing milk samples containing various concentrations of S. aureus from pure milk and milk contaminated with Escherichia coli (E. coli) and Salmonella. Distinction of these samples was made possible by projecting the electrical impedance data with the interactive document mapping (IDMAP) technique. The high sensitivity and selectivity are attributed to the highly specific interaction with anti-S. aureus antibodies captured with polarization-modulated reflection absorption spectroscopy (PM-IRRAS), with adsorption on the antibodies explained with the Langmuir–Freundlich model. Since these immunosensors are stable for up to 25 days and detection measurements can be made within minutes, the methodology proposed is promising for monitoring S. aureus contamination in the food industry and hospitals, and in detecting bovine mastitis.
- 6 August 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (18) , 6014-6023
Controlled molecular architectures in microfluidic immunosensors for detecting Staphylococcus aureus
Detection of pathogenic microorganisms is essential for food quality control and diagnosis of various diseases, which is currently performed with high-cost, sophisticated methods. In this paper, we report on a low-cost detection method based on impedance spectroscopy to detect Staphylococcus aureus (S. aureus). The immunosensors were made with microfluidic devices made of interdigitated electrodes coated with layer-by-layer (LbL) films of chitosan and chondroitin sulfate, on which a layer of anti-S. aureus antibodies was adsorbed. The limit of detection was 2.83 CFU mL−1 with a limit of quantification of 9.42 CFU mL−1 for immunosensors with 10-bilayer LbL films. This level of sensitivity is sufficient to detect traces of bacteria that cause mastitis in milk, which we have confirmed by distinguishing milk samples containing various concentrations of S. aureus from pure milk and milk contaminated with Escherichia coli (E. coli) and Salmonella. Distinction of these samples was made possible by projecting the electrical impedance data with the interactive document mapping (IDMAP) technique. The high sensitivity and selectivity are attributed to the highly specific interaction with anti-S. aureus antibodies captured with polarization-modulated reflection absorption spectroscopy (PM-IRRAS), with adsorption on the antibodies explained with the Langmuir–Freundlich model. Since these immunosensors are stable for up to 25 days and detection measurements can be made within minutes, the methodology proposed is promising for monitoring S. aureus contamination in the food industry and hospitals, and in detecting bovine mastitis.