  • Hamdy Hassan

    Mechanical Engineering Department, Faculty of Engineering, Assiut University, Assiut, Egypt

    3 shared publications
  • Changhong Hu

    Research Institute for Applied Mechanics, Kyushu University, Fukuoka, Japan

    2 shared publications
  • Waheed K. Zahra

    Department of Mathematics, Institute of Basic and Applied Sciences, Egypt-Japan University of Science and Technology (E-JUST), New Borg El-Arab City, 21934, Alexandria, Egypt

    2 shared publications
  • A. A. Hawwash

    Mechanical Engineering Department, Faculty of Engineering, Benha University, Benha, Egypt

    1 shared publication
  • Abdelrahman M. Elshaer

    Mechanical Engineering Department, Faculty of Engineering, Benha University, Benha, Egypt

    1 shared publication
  • Hamdy Hassan

    Energy Resources Engineering Department, Egypt-Japan University of Science and Technology (E-JUST), Alexandria, Egypt

    1 shared publication

Latest Publications

  • Open Access

    Short-memory non-Fourier heat conduction PV model: stability analysis and cooling techniques

    by E. F. El-Gazar, Hamdy Hassan, W. K. Zahra

    A short-memory non-Fourier model (SMNFM) is proposed to simulate the performance of a photovoltaic (PV) panel coupled with two different heat spreader (HS) designs. The proposed model employs a physically justified short-memory fractional formulation to capture transient heat transfer while overcoming the high computational cost associated with conventional long-memory fractional models. To further enhance PV thermal management, the model is integrated with a hybrid cooling strategy combining passive cooling using rectangular and trapezoidal heat spreaders with active water cooling. A finite difference numerical scheme is developed, and its stability is rigorously analyzed using the Von Neumann method for both explicit and implicit formulations. The proposed SMNFM is validated against published experimental data obtained under the hot climatic conditions of Egypt, demonstrating excellent agreement with the measured results. Compared with the classical model, the proposed approach improves prediction accuracy while reducing computational time and memory requirements. The fractional model achieves prediction errors as low as 0.175% for cell temperature and 4.7% for output power. Furthermore, the trapezoidal heat spreader combined with turbulent water cooling provides the best thermal and electrical performance, increasing the PV electrical efficiency to 11.9%. These findings demonstrate that the proposed short-memory fractional framework provides an efficient, accurate, and physically realistic approach for the thermal analysis and optimization of advanced photovoltaic cooling systems.

  • Open Access

    Enhancing solar still performance with hybrid nanofluid: a comprehensive assessment of energy, exergy, economics, and environmental impact using a novel fractional model

    by E. F. El-Gazar, Mohamed S. Yousef, Abdelrahman M. Elshaer, Mahmoud A. Khattab, T. A. Mouneer, A. A. Hawwash

    In the present study, the thermal performance of a modified solar still (MSS) system coupled with hybrid nanofluid (HNF) of titanium oxide (TiO 2 ) and silicon oxide (SiO 2 ) has been investigated theoretically based on energetic, exergetic, economic, and enviroeconomic assessment. The model of the MSS has been introduced using a new numerical technique of the Atangana-Baleanu fractional derivative. The fractional model of the MSS system is presented under various weather circumstances (winter and summer seasons) in Egypt to show the impact of HNF on the MSS output: temperatures, freshwater productivity, exergy, and energy efficiencies. The outcomes of the fractional model are contrasted to those derived from actual experimental data collected under varying climatic conditions in Upper Egypt. Numerical findings demonstrate specific consistency between the experimental results and the proposed model of the solar still (SS), with a percentage of error of 4.65% in freshwater productivity. Moreover, using hybrid nano enhances daily productivity in the summertime by 27.2% and in the wintertime by 21.7%, increasing efficiencies. Additionally, a comparative economic and environmental assessment has been investigated for all the proposed desalination systems without and with HNF. The findings found that the cost per liter of MSS was 44% lower than that of the conventional solar still (CSS) during the summer season. Using exergy and energy approaches, MSS reduced CO 2 by 22% and 29.6% more during the winter.


  • Open Access

    A new fractional Cattaneo model for enhancing the thermal performance of photovoltaic panels using heat spreader: energy, exergy, economic and enviroeconomic (4E) analysis

    by Eman F. El-Gazar, Hamdy Hassan, Sherif I. Rabia, Changhong Hu, Waheed K. Zahra

    : A new fractional non-Fourier (Cattaneo) photovoltaic (PV) model is presented to enhance the thermal performance of a PV system combined with a heat spreader (HS). The fractional Cattaneo model is shown to be effective in examining transient processes across the entirety of a PV system, in contrast to the conventional Fourier model’s inability to predict system performance. Consequently, a comparison is conducted between the classical Fourier model with the fractional Fourier and fractional Cattaneo models for the PV system. The impact of using an aluminum heat spreader, with rectangular and trapezoidal shapes, has been developed under hot and cold climate conditions. The findings show that adding a trapezoidal heat spreader reduced the cell temperature by 20 K in summer and 12 K in winter. The reduction in the PV temperature led to an enhancement in daily average power by approximately 28% and 37% in hot and cold weather, respectively. Moreover, economic, exergoeconomic, and enviroeconomic assessment is introduced. The outcomes revealed that the electrical production costs of the rectangular and trapezoidal HS systems are 0.272 and 0.214 $/kWh, respectively, while about 0.286 $/kWh for the conventional PV panel. Based on the environmental study, the estimated CO2 reduction for PV, PV with rectangular HS, and PV with trapezoidal spreader is 0.5504, 0.7704, and 0.8012 tons, respectively. Finally, real experimental data are used to validate the fractional Cattaneo model. The results demonstrate that there is a great fitting with the measured data, with errors in PV power and exergy efficiency of just 0.628% and 3.84%, respectively, whereas their corresponding values for the classical model are 5.72 and 13.13%.


  • Open Access

    A new fractional Cattaneo model for enhancing the thermal performance of Photovoltaic panels using heat spreader: Energy, exergy, economic and enviroeconomic (4E) analysis

    by Eman El-Gazar, Hamdy Hassan, Sherif Rabia, Changhong Hu, Waheed Zahra

    A new fractional non-Fourier (Cattaneo) photovoltaic (PV) model is developed to improve the thermal performance of a PV system combined with a heat spreader (HS). In contrast to the traditional Fourier model, which is unable to reliably predict system performance, the fractional Cattaneo model proves its efficiency in looking at transient processes throughout the entire PV system. It can also accurately expect PV performance even at short temporal scales. Consequently, a comparison is conducted between the classical Fourier model with the fractional Fourier and fractional Cattaneo models for the PV system. Real experimental data are used to validate the fractional Cattaneo model. The findings show that it perfectly matches the measured data, with an error percentage in PV power and exergy efficiency of only 0.628% and 3.84%, respectively, compared to 5.72% and 13.13% resulted from the classical model. An assessment of the effect of using rectangular and trapezoidal spreaders on output power, electrical efficiency, exergy efficiency, economic, exergoeconomic, and enviroeconomic parameters is introduced and discussed. The outcomes revealed that the electrical production costs of the rectangular and trapezoidal HS systems are 0.272 and 0.214 $/kWh, respectively, while about 0.286 $/kWh for the conventional PV panel. Finally, the findings show that the modified PV systems with the spreader are liked to be greener than the conventional ones.

  • Open Access

    The thermal performance of the photovoltaic panel under the effect of air and water cooling: Modeling and simulation

    by E. F. El-Gazar, Hamdy Hassan, Sherif I. Rabia, W. K. Zahra

    The impact of air and water cooling on the performance of PV panel is studied. A mathematical model of a two-dimensional unsteady of the PV system by using an explicit scheme of finite difference method (FD) with Neumann and Robin boundary conditions is presented. The numerical model is implemented using MATLAB software to calculate the temperature distribution in the whole PV system. The result of the numerical model is validated with experimental data in the hot climate conditions of Egypt. The results prove a good matching between the numerical and the experimental results with an absolute error of the cell temperature of 0.47%. The impact of using the laminar and turbulent flow of water and air on the thermal performance of the PV system is studied. The results found that the water cooling decreases the maximum value of the cell temperature from 335.24 K to 314.38 K, and this decreasing in the cell temperature raises the PV output power and thermal efficiency to reach 8.59 Watt and 11.5% respectively.