DXDuo Xu

Duo Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Duo Xu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Xiang Chen

    MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China

    3 shared publications
  • Haibo Zeng

    Nanjing University of Science and Technology

    2 shared publications
  • Jialin Yang

    MIIT Key Laboratory of Advanced Display Materials and Devices, Jiangsu Engineering Research Center for Quantum Dot Display, Institute of Optoelectronics & Nanomaterials, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, China

    2 shared publications
  • Jong-Hyun Ahn

    Yonsei University

    2 shared publications
  • Kairui Qu

    MIIT Key Laboratory of Advanced Display Materials and Devices, Jiangsu Engineering Research Center for Quantum Dot Display, Institute of Optoelectronics & Nanomaterials, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, China

    2 shared publications
  • Kyungtai Park

    School of Electrical and Electronic Engineering Yonsei University Seoul Republic of Korea

    2 shared publications

Latest Publications

  • Flexible Surface Electrodes for Electrocorticography in Neurological Diseases and Brain‐Computer Interface Applications

    by Duo Xu, Juyeong Hong, Kyungtai Park, Jong‐Hyun Ahn

    Flexible electrocorticography (ECoG) surface electrode arrays have broadened their application scope from clinical neural recording tools to integral components of brain‐computer interface (BCI) systems. Currently used ECoG arrays are typically fabricated with metal contacts embedded in silicone carriers, offering limited mechanical flexibility. This restricts their ability to achieve optimal conformal contact with the brain cortex. Moreover, their channel count is constrained by bulky and cumbersome cabling systems. The recent integration of flexible nanomaterials and advanced patterning techniques into surface electrodes has enabled the development of ultrathin, high‐density arrays that conform intimately to the cortical surface. These arrays incorporate on‐site amplification and multiplexing capabilities while maintaining stable impedance over extended implantation periods. This review article highlights recent technological advancements in ECoG surface electrode arrays, as well as emerging strategies for their application in the diagnosis and treatment of neurological disorders. In addition, it presents current efforts to incorporate surface electrodes into BCI systems through the utilization of neural signals.


  • Two-dimensional semiconductor-based active array for high-fidelity spatiotemporal monitoring of neural activities

    by Duo Xu, Juyeong Hong, Huilin Zhao, Sojeong Pak, Jejung Kim, Anh Tuan Hoang, Kyungtai Park, Beom Jin Kim, Seunghyeon Ji, Jonggyu Choi, et al.

    Advanced monitoring of neural responses has deepened our understanding of brain functions. However, balancing sampling fidelity and spatial resolution of electrocorticography mapping remains a major challenge in neuroscience and neuroelectronics. Here we describe a flexible, two-dimensional molybdenum disulfide (MoS2)-based active array for electrocorticography sensing that uses a dual-transistor multiplexed source follower array architecture. We grow wafer-scale trilayer MoS2 directly on polyimide substrates for a scalable fabrication of active arrays and simultaneously scaling matrices with ultrahigh mapping resolution (up to 51 pixels mm−2). In vitro recordings of epileptiform activities and sinusoidal potential distributions demonstrate the high spatiotemporal resolution for full-bandwidth electrocorticography recordings using the 50 × 50 MoS2-based active arrays, which result from the fast on-site multiplexing speeds (τ ≈ 20 ns) and the megahertz response bandwidth of the transducer. In living mice, the active arrays enable high-fidelity electrocorticography monitoring of multiscale neural processes, including auditory-evoked potentials, tonotopic maps and localized multiunit activities at high frequency. Overall, these results suggest that the MoS2-based active arrays are promising minimally invasive high-fidelity tools for spatiotemporal neuronal monitoring.


  • Vapour–liquid–solid–solid growth of two-dimensional non-layered β-Bi2O3 crystals with high hole mobility

    by Yunhai Xiong, Duo Xu, Yousheng Zou, Lili Xu, Yujie Yan, Jianghua Wu, Chen Qian, Xiufeng Song, Kairui Qu, Tong Zhao, et al.

    Currently, p-type two-dimensional (2D) materials lag behind n-type ones in both quantity and performance, hindering their use in advanced p-channel transistors and complementary logic circuits. Non-layered materials, which make up 95% of crystal structures, hold the potential for superior p-type 2D materials but remain challenging to synthesize. Here we show a vapour–liquid–solid–solid growth of atomically thin (2O3 crystals on a SiO2/Si substrate. These crystals form via a transformation from layered BiOCl intermediates. We further realize 2D β-Bi2O3 transistors with room-temperature hole mobility and an on/off current ratio of 136.6 cm2 V−1 s−1 and 1.2 × 108, respectively. The p-type nature is due to the strong suborbital hybridization of Bi 6s26p3 with O 2p4 at the crystal’s M-point valence band maximum. Our work can be used as a reference that adds more 2D non-layered materials to the 2D toolkit and shows 2D β-Bi2O3 to be promising candidate for future electronics.


  • P‐Type 2D Semiconductors for Future Electronics

    by Yunhai Xiong, Duo Xu, Yiping Feng, Guangjie Zhang, Pei Lin, Xiang Chen

    2D semiconductors represent one of the best candidates to extend Moore's law for their superiorities, such as keeping high carrier mobility and remarkable gate‐control capability at atomic thickness. Complementary transistors and van der Waals junctions are critical in realizing 2D semiconductors‐based integrated circuits suitable for future electronics. N‐type 2D semiconductors have been reported predominantly for the strong electron doping caused by interfacial charge impurities and internal structural defects. By contrast, superior and reliable p‐type 2D semiconductors with holes as majority carriers are still scarce. Not only that, but some critical issues have not been adequately addressed, including their controlled synthesis in wafer size and high quality, defect and carrier modulation, optimization of interface and contact, and application in high‐speed and low‐power integrated devices. Here the material toolkit, synthesis strategies, device basics, and digital electronics closely related to p‐type 2D semiconductors are reviewed. Their opportunities, challenges, and prospects for future electronic applications are also discussed, which would be promising or even shining in the post‐Moore era.


  • Open Access

    Fast and direct identification of SARS‐CoV‐2 variants via 2D InSe field‐effect transistors

    by Duo Xu, Junji Li, Yunhai Xiong, Han Li, Jialin Yang, Wenqiang Liu, Lianfu Jiang, Kairui Qu, Tong Zhao, Xinyu Shi, et al.

    As the COVID‐19 pandemic evolves and new variants emerge, the development of more efficient identification approaches of variants is urgent to prevent continuous outbreaks of SARS‐CoV‐2. Field‐effect transistors (FETs) with two‐dimensional (2D) materials are viable platforms for the detection of virus nucleic acids (NAs) but cannot yet provide accurate information on NA variations. Herein, 2D Indium selenide (InSe) FETs were used to identify SARS‐CoV‐2 variants. The device's mobility and stability were ensured by atomic layer deposition (ALD) of Al2O3. The resulting FETs exhibited sub‐fM detection limits ranging from 10–14 M to 10–8 M. The recognition of single‐nucleotide variations was achieved within 15 min to enable the fast and direct identification of two core mutations (L452R, R203M) in Delta genomes (p < 0.01). Such capability originated from the trap states in oxidized InSe (InSe1−xOx) after ALD, resulting in traps‐involved carrier transport responsive to the negative charges of NAs. In sum, the proposed approach might highly provide epidemiological information for timely surveillance of the COVID pandemic. image