Robert Poel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robert Poel has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Matthias Aebersold
Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
3 shared publications - Ekin Ermiş
Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
3 shared publications - Mauricio Reyes
University of Bern
3 shared publications - Peter Manser
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Switzerland
3 shared publications - Amith J. Kamath
ARTORG Center for Biomedical Research, University of Bern, CH-3010 Bern, Switzerland
2 shared publications - Jonas Willmann
Department of Radiation Oncology, University Hospital Zürich, University of Zürich, Zürich, Switzerland
2 shared publications
Latest Publications
- Open Access
- 6 December 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
A dual-layer quality assurance approach leveraging dose prediction for efficient review of automated contours of organs at risk in the brain in radiotherapy
- 6 December 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
Open AccessA dual-layer quality assurance approach leveraging dose prediction for efficient review of automated contours of organs at risk in the brain in radiotherapy
- Open Access
Deep-Learning-Based Dose Predictor for Glioblastoma–Assessing the Sensitivity and Robustness for Dose Awareness in Contouring
External beam radiation therapy requires a sophisticated and laborious planning procedure. To improve the efficiency and quality of this procedure, machine-learning models that predict these dose distributions were introduced. The most recent dose prediction models are based on deep-learning architectures called 3D U-Nets that give good approximations of the dose in 3D almost instantly. Our purpose was to train such a 3D dose prediction model for glioblastoma VMAT treatment and test its robustness and sensitivity for the purpose of quality assurance of automatic contouring. From a cohort of 125 glioblastoma (GBM) patients, VMAT plans were created according to a clinical protocol. The initial model was trained on a cascaded 3D U-Net. A total of 60 cases were used for training, 15 for validation and 20 for testing. The prediction model was tested for sensitivity to dose changes when subject to realistic contour variations. Additionally, the model was tested for robustness by exposing it to a worst-case test set containing out-of-distribution cases. The initially trained prediction model had a dose score of 0.94 Gy and a mean DVH (dose volume histograms) score for all structures of 1.95 Gy. In terms of sensitivity, the model was able to predict the dose changes that occurred due to the contour variations with a mean error of 1.38 Gy. We obtained a 3D VMAT dose prediction model for GBM with limited data, providing good sensitivity to realistic contour variations. We tested and improved the model’s robustness by targeted updates to the training set, making it a useful technique for introducing dose awareness in the contouring evaluation and quality assurance process.
Open AccessDeep-Learning-Based Dose Predictor for Glioblastoma–Assessing the Sensitivity and Robustness for Dose Awareness in Contouring
External beam radiation therapy requires a sophisticated and laborious planning procedure. To improve the efficiency and quality of this procedure, machine-learning models that predict these dose distributions were introduced. The most recent dose prediction models are based on deep-learning architectures called 3D U-Nets that give good approximations of the dose in 3D almost instantly. Our purpose was to train such a 3D dose prediction model for glioblastoma VMAT treatment and test its robustness and sensitivity for the purpose of quality assurance of automatic contouring. From a cohort of 125 glioblastoma (GBM) patients, VMAT plans were created according to a clinical protocol. The initial model was trained on a cascaded 3D U-Net. A total of 60 cases were used for training, 15 for validation and 20 for testing. The prediction model was tested for sensitivity to dose changes when subject to realistic contour variations. Additionally, the model was tested for robustness by exposing it to a worst-case test set containing out-of-distribution cases. The initially trained prediction model had a dose score of 0.94 Gy and a mean DVH (dose volume histograms) score for all structures of 1.95 Gy. In terms of sensitivity, the model was able to predict the dose changes that occurred due to the contour variations with a mean error of 1.38 Gy. We obtained a 3D VMAT dose prediction model for GBM with limited data, providing good sensitivity to realistic contour variations. We tested and improved the model’s robustness by targeted updates to the training set, making it a useful technique for introducing dose awareness in the contouring evaluation and quality assurance process.
- Open Access
- 11 August 2023
- Published by MDPI AG in Preprints.org
Deep Learning-Based Dose Predictor for Glioblastoma – Assessing the Sensitivity and Robustness for Dose Awareness in Contouring
Background: External beam radiation therapy requires a sophisticated and laborious planning procedure. To improve the efficiency and quality of the planning procedure, machine learning predictions of the dose distributions have been introduced to speed up the planning procedure and to serve as quality assurance. The most recent dose prediction models are based on deep learning U-Nets that give good approximations of the dose in 3D almost instantly. It is our purpose to train a 3D dose prediction for glioblastoma VMAT treatment and test its robustness and sensitivity for the purpose of quality assurance of automatic contouring. Methods: From a cohort of 125 glioblastoma (GBM) patients, VMAT plans were created according to a clinical protocol. The initial model was trained on a concatenated 3D U-Net. A total of 60 cases were used for training, 15 for validation and 20 for testing. The prediction model was tested for sensitivity to dose changes according to realistic contour variations. Additionally, the model was tested for robustness by exposing it to a worst-case test set containing out-of-distribution cases.Results: The initially trained prediction model had a dose score of 0.94 Gy and a mean DVH score for all structures of 1.95 Gy. In terms of sensitivity, the model was able to predict the dose changes that occurred due to the contour variations with a mean error of 1.38 Gy.Conclusions: We obtained a 3D VMAT dose prediction model for GBM with limited data, providing good sensitivity to realistic contour variations. We tested and improved the model's robustness, by targeted updating the training set, making it a useful technique for dose awareness in the contouring evaluation and quality assurance.
- 11 August 2023
- Published by MDPI AG in Preprints.org
Open AccessDeep Learning-Based Dose Predictor for Glioblastoma – Assessing the Sensitivity and Robustness for Dose Awareness in Contouring
Background: External beam radiation therapy requires a sophisticated and laborious planning procedure. To improve the efficiency and quality of the planning procedure, machine learning predictions of the dose distributions have been introduced to speed up the planning procedure and to serve as quality assurance. The most recent dose prediction models are based on deep learning U-Nets that give good approximations of the dose in 3D almost instantly. It is our purpose to train a 3D dose prediction for glioblastoma VMAT treatment and test its robustness and sensitivity for the purpose of quality assurance of automatic contouring. Methods: From a cohort of 125 glioblastoma (GBM) patients, VMAT plans were created according to a clinical protocol. The initial model was trained on a concatenated 3D U-Net. A total of 60 cases were used for training, 15 for validation and 20 for testing. The prediction model was tested for sensitivity to dose changes according to realistic contour variations. Additionally, the model was tested for robustness by exposing it to a worst-case test set containing out-of-distribution cases.Results: The initially trained prediction model had a dose score of 0.94 Gy and a mean DVH score for all structures of 1.95 Gy. In terms of sensitivity, the model was able to predict the dose changes that occurred due to the contour variations with a mean error of 1.38 Gy.Conclusions: We obtained a 3D VMAT dose prediction model for GBM with limited data, providing good sensitivity to realistic contour variations. We tested and improved the model's robustness, by targeted updating the training set, making it a useful technique for dose awareness in the contouring evaluation and quality assurance.
- Open Access
- 22 October 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-18
Impact of random outliers in auto-segmented targets on radiotherapy treatment plans for glioblastoma
To save time and have more consistent contours, fully automatic segmentation of targets and organs at risk (OAR) is a valuable asset in radiotherapy. Though current deep learning (DL) based models are on par with manual contouring, they are not perfect and typical errors, as false positives, occur frequently and unpredictably. While it is possible to solve this for OARs, it is far from straightforward for target structures. In order to tackle this problem, in this study, we analyzed the occurrence and the possible dose effects of automated delineation outliers. First, a set of controlled experiments on synthetically generated outliers on the CT of a glioblastoma (GBM) patient was performed. We analyzed the dosimetric impact on outliers with different location, shape, absolute size and relative size to the main target, resulting in 61 simulated scenarios. Second, multiple segmentation models where trained on a U-Net network based on 80 training sets consisting of GBM cases with annotated gross tumor volume (GTV) and edema structures. On 20 test cases, 5 different trained models and a majority voting method were used to predict the GTV and edema. The amount of outliers on the predictions were determined, as well as their size and distance from the actual target. We found that plans containing outliers result in an increased dose to healthy brain tissue. The extent of the dose effect is dependent on the relative size, location and the distance to the main targets and involved OARs. Generally, the larger the absolute outlier volume and the distance to the target the higher the potential dose effect. For 120 predicted GTV and edema structures, we found 1887 outliers. After construction of the planning treatment volume (PTV), 137 outliers remained with a mean distance to the target of 38.5 ± 5.0 mm and a mean size of 1010.8 ± 95.6 mm3. We also found that majority voting of DL results is capable to reduce outliers. This study shows that there is a severe risk of false positive outliers in current DL predictions of target structures. Additionally, these errors will have an evident detrimental impact on the dose and therefore could affect treatment outcome.
- 22 October 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-18
Open AccessImpact of random outliers in auto-segmented targets on radiotherapy treatment plans for glioblastoma
To save time and have more consistent contours, fully automatic segmentation of targets and organs at risk (OAR) is a valuable asset in radiotherapy. Though current deep learning (DL) based models are on par with manual contouring, they are not perfect and typical errors, as false positives, occur frequently and unpredictably. While it is possible to solve this for OARs, it is far from straightforward for target structures. In order to tackle this problem, in this study, we analyzed the occurrence and the possible dose effects of automated delineation outliers. First, a set of controlled experiments on synthetically generated outliers on the CT of a glioblastoma (GBM) patient was performed. We analyzed the dosimetric impact on outliers with different location, shape, absolute size and relative size to the main target, resulting in 61 simulated scenarios. Second, multiple segmentation models where trained on a U-Net network based on 80 training sets consisting of GBM cases with annotated gross tumor volume (GTV) and edema structures. On 20 test cases, 5 different trained models and a majority voting method were used to predict the GTV and edema. The amount of outliers on the predictions were determined, as well as their size and distance from the actual target. We found that plans containing outliers result in an increased dose to healthy brain tissue. The extent of the dose effect is dependent on the relative size, location and the distance to the main targets and involved OARs. Generally, the larger the absolute outlier volume and the distance to the target the higher the potential dose effect. For 120 predicted GTV and edema structures, we found 1887 outliers. After construction of the planning treatment volume (PTV), 137 outliers remained with a mean distance to the target of 38.5 ± 5.0 mm and a mean size of 1010.8 ± 95.6 mm3. We also found that majority voting of DL results is capable to reduce outliers. This study shows that there is a severe risk of false positive outliers in current DL predictions of target structures. Additionally, these errors will have an evident detrimental impact on the dose and therefore could affect treatment outcome.