Jonas Winkelholz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jonas Winkelholz has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Moritz Hitzemann
Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
6 shared publications - Stefan Zimmermann
Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover
6 shared publications - Alexander Nitschke
Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, 30167 Hannover, Germany
4 shared publications - Martin Lippmann
Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
4 shared publications - Christian Thoben
Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, 30167 Hannover, Germany
2 shared publications - Tim Kobelt
Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in Measurement: Sensors
- Vol. 46
Transimpedance amplifiers: Reaching high gain, low noise and high bandwidth
- 24 June 2026
- Published by Elsevier in Measurement: Sensors
- Vol. 46
Open AccessTransimpedance amplifiers: Reaching high gain, low noise and high bandwidth
- Open Access
- 19 April 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1358, 344097
Ion mobility spectrometer with heated sample inlet - Solution to the issue of temperature effect on resolving power
- 19 April 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1358, 344097
Open AccessIon mobility spectrometer with heated sample inlet - Solution to the issue of temperature effect on resolving power
- Open Access
- 12 September 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1736, 465376
A hyper-fast gas chromatograph coupled to an ion mobility spectrometer with high repetition rate and flow-optimized ion source to resolve the short chromatographic peaks
- 12 September 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1736, 465376
Open AccessA hyper-fast gas chromatograph coupled to an ion mobility spectrometer with high repetition rate and flow-optimized ion source to resolve the short chromatographic peaks
- Open Access
- 9 July 2024
- Published by Elsevier in Renewable Energy
- Vol. 231
Ultra-fast polarity switching GC-IMS for the analysis of volatiles in biogas
- 9 July 2024
- Published by Elsevier in Renewable Energy
- Vol. 231
Open AccessUltra-fast polarity switching GC-IMS for the analysis of volatiles in biogas
- Open Access
- 7 June 2024
- Published by MDPI AG in Electronics
- Vol. 13 (12) , 2247
Continuous Recording of Resonator Characteristics Using Single-Sideband Modulation
Electrical resonators are usually characterized by their resonance frequency, attenuation and quality factor. External quantities can affect these parameters, resulting in a characteristic change in the resonator, which can be used as a sensor effect. This work presents a new concept and electronic device for the continuous recording of resonator characteristics using single-sideband modulation. A test signal consisting of a center frequency and two sidebands is generated and the center frequency is set close to the resonator’s resonance frequency while the two sidebands are adjusted symmetrically around the center frequency. By exiting the resonator with the test signal and demodulating the resulting output into individual frequency components, a continuous measurement of the attenuation is possible. The center frequency is adjusted so that both sidebands have equal attenuation, resulting in a center frequency that corresponds to the resonance frequency of the resonator. If the resonator does not show a symmetrical frequency response, the sideband attenuation ratio can be adjusted accordingly. Continuous recording of the resonator characteristics at a sampling rate of 100 Sps was verified using a digitally tunable RLC series resonator with resonance frequencies between 250 MHz and 450 MHz, resulting in a maximum error below 1.5%.
- 7 June 2024
- Published by MDPI AG in Electronics
- Vol. 13 (12) , 2247
Open AccessContinuous Recording of Resonator Characteristics Using Single-Sideband Modulation
Electrical resonators are usually characterized by their resonance frequency, attenuation and quality factor. External quantities can affect these parameters, resulting in a characteristic change in the resonator, which can be used as a sensor effect. This work presents a new concept and electronic device for the continuous recording of resonator characteristics using single-sideband modulation. A test signal consisting of a center frequency and two sidebands is generated and the center frequency is set close to the resonator’s resonance frequency while the two sidebands are adjusted symmetrically around the center frequency. By exiting the resonator with the test signal and demodulating the resulting output into individual frequency components, a continuous measurement of the attenuation is possible. The center frequency is adjusted so that both sidebands have equal attenuation, resulting in a center frequency that corresponds to the resonance frequency of the resonator. If the resonator does not show a symmetrical frequency response, the sideband attenuation ratio can be adjusted accordingly. Continuous recording of the resonator characteristics at a sampling rate of 100 Sps was verified using a digitally tunable RLC series resonator with resonance frequencies between 250 MHz and 450 MHz, resulting in a maximum error below 1.5%.
- Open Access
- 25 October 2022
- Published by MDPI AG in Electronics
- Vol. 11 (21) , 3446
Resistive High-Voltage Probe with Frequency Compensation by Planar Compensation Electrode Integrated in Printed Circuit Board Design
Resistive voltage dividers tend to have a highly non-linear transfer function as parasitic and stray capacitances exert an increasing influence with increasing frequency. The non-linear transfer function depends on the topology and resistors used and consists of a low-pass filter with an additional high-pass component in the GHz range. Due to the non-linear transfer function the measured signal differs from the original input signal. Here, we present an improved resistive voltage divider with additional compensation capacities to extend the linear bandwidth. With this new concept, the linear bandwidth is improved from 115 kHz to 88 MHz, while maintaining a DC input impedance of 10 MΩ. For high-voltage insulation and easy manufacturing, surface mounted resistors on a printed circuit board with a compensation electrode on the adjacent side are used. The performance of this resistive voltage divider is demonstrated by measuring a series of high-voltage pulses with an amplitude of 2.5 kVpeak-peak. The measured pulse rise time is about 16 ns, corresponding to an average slew-rate of 150 V/ns. Finally, the developed resistive voltage divider is successfully used to measure fast high-voltage transients required for advanced ion mobility spectrometers with integrated collision induced fragmentation.
- 25 October 2022
- Published by MDPI AG in Electronics
- Vol. 11 (21) , 3446
Open AccessResistive High-Voltage Probe with Frequency Compensation by Planar Compensation Electrode Integrated in Printed Circuit Board Design
Resistive voltage dividers tend to have a highly non-linear transfer function as parasitic and stray capacitances exert an increasing influence with increasing frequency. The non-linear transfer function depends on the topology and resistors used and consists of a low-pass filter with an additional high-pass component in the GHz range. Due to the non-linear transfer function the measured signal differs from the original input signal. Here, we present an improved resistive voltage divider with additional compensation capacities to extend the linear bandwidth. With this new concept, the linear bandwidth is improved from 115 kHz to 88 MHz, while maintaining a DC input impedance of 10 MΩ. For high-voltage insulation and easy manufacturing, surface mounted resistors on a printed circuit board with a compensation electrode on the adjacent side are used. The performance of this resistive voltage divider is demonstrated by measuring a series of high-voltage pulses with an amplitude of 2.5 kVpeak-peak. The measured pulse rise time is about 16 ns, corresponding to an average slew-rate of 150 V/ns. Finally, the developed resistive voltage divider is successfully used to measure fast high-voltage transients required for advanced ion mobility spectrometers with integrated collision induced fragmentation.