Zichun Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zichun Zhou has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Guofeng He
College of Electrical Engineering & New Energy, China Three Gorges University, Yichang 443002, China
3 shared publications - Cheng Yan
Ningbo Deye Technology Co., Ltd., Ningbo 315803, China
1 shared publication Gou-Jiao Li
Department of School of Electrical and Control Engineering, Henan University of Urban Construction, Pingding Shan, China
1 shared publication- Guojiao Li
School of Electrical and Control Engineering, Henan University of Urban Construction, Pingdingshan 467036, China
1 shared publication - Junfang Lin
School of Electrical and Control Engineering, Henan University of Urban Construction, Pingdingshan 467036, China
1 shared publication - Shuang Luo
College of Electrical Engineering & New Energy, China Three Gorges University, Yichang 443002, China
1 shared publication
Latest Publications
- Open Access
Fixed-Time Robust Fractional-Order Sliding Mode Control Strategy for Grid-Connected Inverters Based on Weighted Average Current
To address the issues of high computational load and slow dynamic performance in traditional fractional-order sliding mode control for LCL-type grid-connected inverters, this paper proposes a fixed-time robust fractional-order sliding mode control strategy based on weighted average current control. Firstly, the weighted average current control (WACC) is used to reduce the third-order LCL filter to the first order, which simplifies the system model; secondly, in order to suppress the disturbance caused by the filter parameter perturbation to the weighted average current accuracy, a fixed-time disturbance observer (FTDO) is used to quickly estimate the disturbance caused by the filter parameter perturbation in a fixed time, so as to improve the anti-interference ability of the system; moreover, a fixed-time fractional-order sliding mode controller (FTFOSMC) is designed to achieve rapid tracking of the incoming reference current, and the stability of the proposed control strategy is confirmed by the strict Lyapunov method, which proves that the upper bound of the stability time is independent of the initial state of the system. Finally, simulation and experimental results show that the proposed method has better steady-state performance and a higher dynamic performance.
Open AccessFixed-Time Robust Fractional-Order Sliding Mode Control Strategy for Grid-Connected Inverters Based on Weighted Average Current
To address the issues of high computational load and slow dynamic performance in traditional fractional-order sliding mode control for LCL-type grid-connected inverters, this paper proposes a fixed-time robust fractional-order sliding mode control strategy based on weighted average current control. Firstly, the weighted average current control (WACC) is used to reduce the third-order LCL filter to the first order, which simplifies the system model; secondly, in order to suppress the disturbance caused by the filter parameter perturbation to the weighted average current accuracy, a fixed-time disturbance observer (FTDO) is used to quickly estimate the disturbance caused by the filter parameter perturbation in a fixed time, so as to improve the anti-interference ability of the system; moreover, a fixed-time fractional-order sliding mode controller (FTFOSMC) is designed to achieve rapid tracking of the incoming reference current, and the stability of the proposed control strategy is confirmed by the strict Lyapunov method, which proves that the upper bound of the stability time is independent of the initial state of the system. Finally, simulation and experimental results show that the proposed method has better steady-state performance and a higher dynamic performance.
- 15 August 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (3) , 1369-1378
Research on DC Component Disturbance Suppression Strategy of Islanded T-Type Three-Level Inverter Based on Improved Backstepping Control Theory
- 15 August 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (3) , 1369-1378
Research on DC Component Disturbance Suppression Strategy of Islanded T-Type Three-Level Inverter Based on Improved Backstepping Control Theory
- Open Access
Robust Suppression Strategy for Photovoltaic Grid-Connected Inverter Cluster Resonance Based on Kalman Filter Improved Disturbance Observer
In response to the key engineering problems of photovoltaic grid-connected inverter cluster resonance suppression affected by grid-connected inverter impedance, in this paper, a control strategy based on a disturbance observer is proposed to dynamically compensate for the damping coefficient of the controlled system and improve the robustness of the system. First, an engineering mathematical model of a 200 MW photovoltaic inverter cluster is established, and the mechanism of the active damping of the cluster inverter influenced by the disturbance is analyzed. Secondly, the capacitor current feedback is utilized to constitute the virtual damping, and the inverter output impedance is reshaped to suppress the resonance peak. Then, a Kalman filter is used to improve the traditional disturbance observer to accurately detect disturbance of the system during the dynamic process of the cluster inverter so as to better adapt to changes in grid impedance and dynamically compensate for the virtual damping of the cluster resonant system. Finally, the proposed control strategy is verified with respect to a practical PV power station. The experimental results demonstrate the feasibility of the proposed control method.
Open AccessRobust Suppression Strategy for Photovoltaic Grid-Connected Inverter Cluster Resonance Based on Kalman Filter Improved Disturbance Observer
In response to the key engineering problems of photovoltaic grid-connected inverter cluster resonance suppression affected by grid-connected inverter impedance, in this paper, a control strategy based on a disturbance observer is proposed to dynamically compensate for the damping coefficient of the controlled system and improve the robustness of the system. First, an engineering mathematical model of a 200 MW photovoltaic inverter cluster is established, and the mechanism of the active damping of the cluster inverter influenced by the disturbance is analyzed. Secondly, the capacitor current feedback is utilized to constitute the virtual damping, and the inverter output impedance is reshaped to suppress the resonance peak. Then, a Kalman filter is used to improve the traditional disturbance observer to accurately detect disturbance of the system during the dynamic process of the cluster inverter so as to better adapt to changes in grid impedance and dynamically compensate for the virtual damping of the cluster resonant system. Finally, the proposed control strategy is verified with respect to a practical PV power station. The experimental results demonstrate the feasibility of the proposed control method.