AWArtur Weidner

Artur Weidner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Artur Weidner has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Christina Stengl

    Division of Medical Physics in Radiation Oncology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Heidelberg, BW, 69120, GERMANY

    2 shared publications
  • Armin Runz

    Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120

    1 shared publication
  • Brennah Murphy

    The Wistar Institute, Philadelphia, PA 19104, USA

    1 shared publication
  • Christian Neelsen

    Department of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120

    1 shared publication
  • Eric Arbes

    Division of Medical Physics, Department of Radiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany

    1 shared publication
  • Fabian Dinkel

    Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120

    1 shared publication

Latest Publications

  • Open Access

    A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer

    by Christina Stengl, Kathrin Panow, Eric Arbes, Iván D Muñoz, Jeppe B Christensen, Christian Neelsen, Fabian Dinkel, Artur Weidner, Armin Runz, Wibke Johnen, et al.

    Objective . Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs’ motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphic P ancreas P hantom for I on-b e am T herapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy. Approach . The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs’ organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients’ 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films. Main results . PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude. Significance . A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests.


  • Open Access

    Development of an Artificial 3D Liver Phantom for Analysis of Radiotherapeutic Effects In Vitro

    by Christina Stengl, Shahrouz Ghafoory, Artur Weidner, Brennah Murphy, Stefan Wölfl

    Over recent decades, stereotactic body radiotherapy has garnered increasing popularity. Unfortunately, conventional preclinical 2D in vitro models are often insufficient for studying radiotherapy effects. Therefore, in this study, we developed a novel anthropomorphic in vitro liver phantom, which simulates the relevant hepatocellular carcinoma (HCC) tumor microenvironment and spatial organization. The liver phantom was 3D printed, filled with tissue-mimicking agarose mixture, and designed to fit ten microfluidic chips (MCs), in which HepG2 cells were seeded. Airtight MCs induced hypoxic conditions, as verified by Hif1α staining. Irradiation was conducted with 20 Gy in one fraction using a CyberKnife, in either a 2D setup, or by irradiating MCs arranged in the 3D-printed liver model using an individually calculated treatment plan. Post-irradiation cellular damage was determined via γH2AX staining. Here, we demonstrate a new physiologically relevant approach to model HCC pathology following radiotherapy. Comparing γH2AX staining in normoxic conditions to cells grown in MCs (hypoxic conditions) revealed a reduction in cellular damage of 30.24% (p = 0.0001) in the hypoxic environment. Moreover, we compared the scattering effect of radiation on a conventional 2D in vitro model to our new 3D anthropomorphic liver phantom and observed a significant γH2AX intensity reduction of 9.6% (p = 0.0294) in HepG2 cells irradiated in the phantom. Our approach of utilizing a liver phantom takes into account the hypoxic tumor microenvironment and 3D scattering effects of tissue irradiation, thereby modeling both physical and biological parameters of HCC tumors. The use of tissue phantoms lays the groundwork for future examination of other hypoxic tumors and offers a more comprehensive approach for screening and analysis of novel cancer therapeutics.