Lei Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Yang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Sheng Shen
A. A. Martinos Center for Biomedical Imaging Massachusetts General Hospital Charlestown MA USA
3 shared publications - Zheng Xu
Chongqing University
3 shared publications - Wei He
Chongqing University
2 shared publications - An Pan
Department of Epidemiology and Biostatistics, Ministry of Education Key Laboratory of Environment and Health, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication C Q Yu
Department of Epidemiology and Biostatistics, School of Public Health, Peking University/Peking University Center for Public Health and Epidemic Preparedness & Response/Peking University Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education, Beijing 100191, China
1 shared publicationJ Wu
Department of Epidemiology and Biostatistics, and Ministry of Education Key Laboratory of Environment and Health, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
1 shared publication
Latest Publications
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
An Exploration of Parallel Imaging System for Very-Low-Field (50 mT) MRI Scanner
Reducing the scanning time of very-low field (VLF) magnetic resonance imaging (MRI) scanners, commonly employed for stroke diagnosis, can enhance patient comfort and operational efficiency. The conventional parallel imaging (PI) technique for high-field MRI should be tailored to apply here, considering the differences in the direction of the main magnetic field and the presence of noise. A VLF-specific PI algorithm and phased-array coil are proposed, marking the first application of PI in VLF MRI. Reconstruction quality is enhanced by denoising undersampled k-space data using a linear-prediction based Kalman filter. Subsequently, the denoised k-space data are nonlinearly mapped from the original space onto a high-dimensional feature space, utilizing a polynomial feature mapping defined nonlinear frame. Frame parameters are calculated using auto-calibration signals (ACS) from the center k-space, and missing phase-encoding lines in the original space are estimated using acquired lines in the feature space. An 8-channel phased-array coil, designed for a vertical main magnetic field, is decoupled using geometric overlap and a low input impedance (LII) preamplifier. Healthy volunteer head imaging experiments using the proposed PI technique exhibit the lowest mean-squared-error (MSE) value and the highest peak-signal-to-noise (PSNR) and structural similarity index (SSIM) values compared to two widely used PI methods. The proposed PI technique enables the VLF MRI scanner to achieve similar image quality and a 72.5% improvement in signal-to-noise ratio (SNR) compared to fully sampled images while requiring less than 50% of the scan time. We present a PI technique tailored for VLF MRI scanner for the first time, along with potential research direction to achieve greater reduction factor.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
An Exploration of Parallel Imaging System for Very-Low-Field (50 mT) MRI Scanner
Reducing the scanning time of very-low field (VLF) magnetic resonance imaging (MRI) scanners, commonly employed for stroke diagnosis, can enhance patient comfort and operational efficiency. The conventional parallel imaging (PI) technique for high-field MRI should be tailored to apply here, considering the differences in the direction of the main magnetic field and the presence of noise. A VLF-specific PI algorithm and phased-array coil are proposed, marking the first application of PI in VLF MRI. Reconstruction quality is enhanced by denoising undersampled k-space data using a linear-prediction based Kalman filter. Subsequently, the denoised k-space data are nonlinearly mapped from the original space onto a high-dimensional feature space, utilizing a polynomial feature mapping defined nonlinear frame. Frame parameters are calculated using auto-calibration signals (ACS) from the center k-space, and missing phase-encoding lines in the original space are estimated using acquired lines in the feature space. An 8-channel phased-array coil, designed for a vertical main magnetic field, is decoupled using geometric overlap and a low input impedance (LII) preamplifier. Healthy volunteer head imaging experiments using the proposed PI technique exhibit the lowest mean-squared-error (MSE) value and the highest peak-signal-to-noise (PSNR) and structural similarity index (SSIM) values compared to two widely used PI methods. The proposed PI technique enables the VLF MRI scanner to achieve similar image quality and a 72.5% improvement in signal-to-noise ratio (SNR) compared to fully sampled images while requiring less than 50% of the scan time. We present a PI technique tailored for VLF MRI scanner for the first time, along with potential research direction to achieve greater reduction factor.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (3) , 2905-2914
An Exploration of a Phased-Array RF Coil for Very Low-Field Brain MRI
Very-low magnetic field (VLF) magnetic resonance imaging (MRI) presents an affordable and easily deployable solution, facilitating MRI usage within inpatient wards, intensive care units (ICU), ambulances, and resource-limited areas. Despite the advantages, VLF MRI encounters challenges like a reduced signal-to-noise ratio (SNR). While high field MRI have employed phased-array RF coils to enhance SNR and expedite imaging, leveraging phased-array RF coil to improve imaging SNR and reduce scan time in VLF MRI has been highly expected. Compared to high field MRI, the dramatically reduced working frequency has a significant impact on the performance of the phased-array RF coil for VLF MRI. In this study, we attempted to evaluate the performance of phased-array RF coils for VLF MRI. Specifically, we built a phased-array RF coil system, which consists of an optimized 8-channel head RF coil, and a custom-made low input impedance (LII) preamplifier. We optimized the system based on impedance analysis and evaluate its performance by bench test, phantom imaging and healthy volunteer imaging. This paper presents the first attempt to develop phased-array RF coil for VLF MRI, and revealed the advantage of improving SNR by RF coil structure optimization and the challenge of phased-array decoupling in VLF MRI.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (3) , 2905-2914
An Exploration of a Phased-Array RF Coil for Very Low-Field Brain MRI
Very-low magnetic field (VLF) magnetic resonance imaging (MRI) presents an affordable and easily deployable solution, facilitating MRI usage within inpatient wards, intensive care units (ICU), ambulances, and resource-limited areas. Despite the advantages, VLF MRI encounters challenges like a reduced signal-to-noise ratio (SNR). While high field MRI have employed phased-array RF coils to enhance SNR and expedite imaging, leveraging phased-array RF coil to improve imaging SNR and reduce scan time in VLF MRI has been highly expected. Compared to high field MRI, the dramatically reduced working frequency has a significant impact on the performance of the phased-array RF coil for VLF MRI. In this study, we attempted to evaluate the performance of phased-array RF coils for VLF MRI. Specifically, we built a phased-array RF coil system, which consists of an optimized 8-channel head RF coil, and a custom-made low input impedance (LII) preamplifier. We optimized the system based on impedance analysis and evaluate its performance by bench test, phantom imaging and healthy volunteer imaging. This paper presents the first attempt to develop phased-array RF coil for VLF MRI, and revealed the advantage of improving SNR by RF coil structure optimization and the challenge of phased-array decoupling in VLF MRI.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3415-3426
Active EMI Suppression System for a 50 mT Unshielded Portable MRI Scanner
Objective: Passive shielding is usually applied to block electro-magnetic interference (EMI) for portable very-low field MRI scanners, but it goes against the mobility of the scanners. Here, the reference channel-based active EMI suppression (AES) system was proposed to discard them. Methods: Different from the existing studies, this work started with analyzing the interference transmission paths and discovered that the human body coupling was the main path. Then, the “ring-” shaped EMI receiving coil designed here together with the electrocardiograph (ECG) electrode patch were used to suppress the human-body-coupled interferences. For the first time, the periphery data of the k -spaces of the RF coil and the EMI detectors were utilized to calculate the transfer factors in multiple frequency bands by using the least square method. The reference EMI signals were transferred to the interferences in the MR signal by multiplying the transfer factors in each frequency band, and the denoised MR signal could be obtained by subtracting the transferred reference EMI signals. Results: The prototype of the AES system was applied to a 50 mT unshielded portable MRI scanner. The in-vivo experiments indicated that the interference suppression rate of the AES system equipped with the “ring-” shaped EMI receiving coil could reach 96.8%. Meanwhile, the SNR of the images after interference suppression by the AES system equipped with both types of detectors was 97.2% of that of the images scanned inside the shielded room. Conclusion: The proposed AES system ensures that the portable MRI scanner works normally in unshielded environment. Significance: Our study provides a solution to make portable MRI scanners truly movable.
- 26 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3415-3426
Active EMI Suppression System for a 50 mT Unshielded Portable MRI Scanner
Objective: Passive shielding is usually applied to block electro-magnetic interference (EMI) for portable very-low field MRI scanners, but it goes against the mobility of the scanners. Here, the reference channel-based active EMI suppression (AES) system was proposed to discard them. Methods: Different from the existing studies, this work started with analyzing the interference transmission paths and discovered that the human body coupling was the main path. Then, the “ring-” shaped EMI receiving coil designed here together with the electrocardiograph (ECG) electrode patch were used to suppress the human-body-coupled interferences. For the first time, the periphery data of the k -spaces of the RF coil and the EMI detectors were utilized to calculate the transfer factors in multiple frequency bands by using the least square method. The reference EMI signals were transferred to the interferences in the MR signal by multiplying the transfer factors in each frequency band, and the denoised MR signal could be obtained by subtracting the transferred reference EMI signals. Results: The prototype of the AES system was applied to a 50 mT unshielded portable MRI scanner. The in-vivo experiments indicated that the interference suppression rate of the AES system equipped with the “ring-” shaped EMI receiving coil could reach 96.8%. Meanwhile, the SNR of the images after interference suppression by the AES system equipped with both types of detectors was 97.2% of that of the images scanned inside the shielded room. Conclusion: The proposed AES system ensures that the portable MRI scanner works normally in unshielded environment. Significance: Our study provides a solution to make portable MRI scanners truly movable.
- 10 May 2021
- Published by Wolters Kluwer Health in Zhonghua Liu Xing Bing Xue Za Zhi = Zhonghua Liuxingbingxue Zazhi
- Vol. 42 (5) , 763-770
[Self-rated health measures and their relations to all-cause and cardiovascular mortality in adults from 10 regions of China].
Objective: To examine the association between self-rated health status (SRH) and all-cause and cardiovascular mortality. Methods: A total of 512 713 adults aged 30-79 years from 10 areas of China were followed from baseline (2004-2008) until 31 December 2016 in the China Kadoorie Biobank study. Global and age-comparative SRH [general self-rated health status (GSRH) and age-comparative self-rated health status (ASRH), respectively] were asked in baseline questionnaires. Causes for mortality were monitored through linkage with established Disease Surveillance Point system and health insurance records. Multivariable Cox proportional regression models were used to estimate the HRs and 95%CIs for the association between SRH measures and all-cause or cardiovascular mortality. Results: During an average of 9.9 years' follow-up, 44 065 deaths were recorded, among which 17 648 were from cardiovascular disease. Compared with excellent GSRH, the HR(95%CI) for all-cause and cardiovascular mortality associated with poor GSRH was 1.84(1.78-1.91) and 1.94(1.82-2.06), respectively. Relative to better ASRH, the HR(95%CI) for all-cause and cardiovascular mortality associated with worse ASRH was 1.75(1.70-1.81) and 1.83(1.73-1.92), respectively. Conclusion: In this large prospective cohort study in China, participants reporting poor GSRH or worse ASRH had significantly higher risk of all-cause and cardiovascular mortality.
- 10 May 2021
- Published by Wolters Kluwer Health in Zhonghua Liu Xing Bing Xue Za Zhi = Zhonghua Liuxingbingxue Zazhi
- Vol. 42 (5) , 763-770
[Self-rated health measures and their relations to all-cause and cardiovascular mortality in adults from 10 regions of China].
Objective: To examine the association between self-rated health status (SRH) and all-cause and cardiovascular mortality. Methods: A total of 512 713 adults aged 30-79 years from 10 areas of China were followed from baseline (2004-2008) until 31 December 2016 in the China Kadoorie Biobank study. Global and age-comparative SRH [general self-rated health status (GSRH) and age-comparative self-rated health status (ASRH), respectively] were asked in baseline questionnaires. Causes for mortality were monitored through linkage with established Disease Surveillance Point system and health insurance records. Multivariable Cox proportional regression models were used to estimate the HRs and 95%CIs for the association between SRH measures and all-cause or cardiovascular mortality. Results: During an average of 9.9 years' follow-up, 44 065 deaths were recorded, among which 17 648 were from cardiovascular disease. Compared with excellent GSRH, the HR(95%CI) for all-cause and cardiovascular mortality associated with poor GSRH was 1.84(1.78-1.91) and 1.94(1.82-2.06), respectively. Relative to better ASRH, the HR(95%CI) for all-cause and cardiovascular mortality associated with worse ASRH was 1.75(1.70-1.81) and 1.83(1.73-1.92), respectively. Conclusion: In this large prospective cohort study in China, participants reporting poor GSRH or worse ASRH had significantly higher risk of all-cause and cardiovascular mortality.
- Open Access
- 10 November 2019
- Published by Springer Nature in Journal of Plant Pathology
- Vol. 102 (2) , 533
First report of tobacco vein banding mosaic virus infecting Solanum lyratum Thunb in China
- 10 November 2019
- Published by Springer Nature in Journal of Plant Pathology
- Vol. 102 (2) , 533
Open AccessFirst report of tobacco vein banding mosaic virus infecting Solanum lyratum Thunb in China