Runu Banerjee Roy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Runu Banerjee Roy has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Shreya Nag
Department of Electronics and Communication Engineering, University of Engineering and Management, Kolkata, India
22 shared publications - Debangana Das
Department of Electronics and Instrumentation Engineering, National Institute of Technology Agartala, Agartala, Tripura, India
19 shared publications - Bipan Tudu
Jadavpur University
14 shared publications - Rajib Bandyopadhyay
Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata, India
13 shared publications - Panchanan Pramanik
Dept. of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata, India
7 shared publications - Mahuya Bhattacharyya Banerjee
Government College of Engineering and Textile Technology, Serampore, India
6 shared publications
Latest Publications
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 1562-1568
A Customized Electronic Tongue by Developing an Array of Molecular Imprinted Polymer-Based Voltammetric Electrodes for Tea Quality Evaluation
In this facile approach, a well-developed voltammetric electronic tongue (e-tongue) consisting of an array of molecular imprinted polymer (MIP) electrodes has been designed for the detection of theophylline (TH), tannic acid (TAN) and total theaflavins (TF) in real samples of black tea. These compounds are responsible for having a high impact on the taste of tea in terms of astringency, thus contributing to the taste of tea infusion. The developed e-tongue has been found to detect the signatures of these analytes from different tea samples under the same conditions. Thus, this e-tongue, in conjunction with a switching circuit, has been able to extract current responses from the working electrodes, giving an overall signature of the tea quality. The differential pulse voltammograms (DPV) responses were obtained to assess the performance on introducing MIP electrodes into the black tea samples. The obtained dataset was subject to the gradient boosting method. The prediction model was designed based on the responses of the e-tongue and yielded a mean-squared error (MSE) of 0.00003 and a coefficient of determination (R²) of 0.967 for the fused data responses. From the explained variance score and R-square value, it is clear that the overall quality of tea has been predicted better for the sensor array when considering the individual dataset from each sensor. On application of t-SNE (t-Distributed Stochastic Neighbour Embedding) on the fused data set, successful discrimination among the different black tea samples was obtained. The results point towards the possibility of an e-tongue based on an array of MIP electrodes to detect the quality of black tea liquor.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 1562-1568
A Customized Electronic Tongue by Developing an Array of Molecular Imprinted Polymer-Based Voltammetric Electrodes for Tea Quality Evaluation
In this facile approach, a well-developed voltammetric electronic tongue (e-tongue) consisting of an array of molecular imprinted polymer (MIP) electrodes has been designed for the detection of theophylline (TH), tannic acid (TAN) and total theaflavins (TF) in real samples of black tea. These compounds are responsible for having a high impact on the taste of tea in terms of astringency, thus contributing to the taste of tea infusion. The developed e-tongue has been found to detect the signatures of these analytes from different tea samples under the same conditions. Thus, this e-tongue, in conjunction with a switching circuit, has been able to extract current responses from the working electrodes, giving an overall signature of the tea quality. The differential pulse voltammograms (DPV) responses were obtained to assess the performance on introducing MIP electrodes into the black tea samples. The obtained dataset was subject to the gradient boosting method. The prediction model was designed based on the responses of the e-tongue and yielded a mean-squared error (MSE) of 0.00003 and a coefficient of determination (R²) of 0.967 for the fused data responses. From the explained variance score and R-square value, it is clear that the overall quality of tea has been predicted better for the sensor array when considering the individual dataset from each sensor. On application of t-SNE (t-Distributed Stochastic Neighbour Embedding) on the fused data set, successful discrimination among the different black tea samples was obtained. The results point towards the possibility of an e-tongue based on an array of MIP electrodes to detect the quality of black tea liquor.
- 30 November 2025
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 269
Online monitoring of phytochemical dynamics in black tea processing using MIP-driven classifier models
- 30 November 2025
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 269
Online monitoring of phytochemical dynamics in black tea processing using MIP-driven classifier models
- 20 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Towards the development of an integrated, user friendly, voltammetric electrode for the electrochemical sensing of food quality
- 20 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Towards the development of an integrated, user friendly, voltammetric electrode for the electrochemical sensing of food quality
- 2 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (21) , 39418-39425
A Novel Molecular Imprinted Dual-Polymer Infused Capacitive Sensor for Quercetin Detection in Agro Products
A novel, cost-effective capacitive sensor using molecularly imprinted dual polymer (MIP) was developed for precise quercetin (QT) detection in agro-products. A unique composite sensing material, molecularly imprinted polydopamine-polyethylene glycol (M2P-QT@C), deposited onto a copper (Cu) plate, forms the sensing heart of the sensor. The sensing material's characteristics were investigated employing a trio of techniques: i) scanning electron microscopy (SEM) for high-magnification structural visualization, ii)X-ray diffraction (XRD) for atomic arrangement analysis, and iii)UV-Vis spectroscopy to confirm template molecule removal and assess potential structural changes. Frequency variation of three electrical parameters: parallel capacitance (Cpqt), impedance (Zqt), and phase angle (θpqt) have been investigated. The sensor responded linearly to QT concentrations from 10 to 50 ppm, with exceptional sensitivity (LOD: 0.035 μg/kg, LOQ: 0.116 μg/kg). To predict the amount of QT in real samples, two statistical methods: i) principal component regression (PCR), and ii) partial least squares regression (PLSR) have been applied, which exhibit high accuracy and recovery, exceeding 90% with minimal error (RMSEC: 0.0015). Additionally, the sensor demonstrated excellent selectivity with remarkable stability for QT recognition in real samples. Even after three months of use, the maximum parallel capacitance (Cpqtm) increased by only 0.4 %, highlighting minimal performance degradation over time.
- 2 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (21) , 39418-39425
A Novel Molecular Imprinted Dual-Polymer Infused Capacitive Sensor for Quercetin Detection in Agro Products
A novel, cost-effective capacitive sensor using molecularly imprinted dual polymer (MIP) was developed for precise quercetin (QT) detection in agro-products. A unique composite sensing material, molecularly imprinted polydopamine-polyethylene glycol (M2P-QT@C), deposited onto a copper (Cu) plate, forms the sensing heart of the sensor. The sensing material's characteristics were investigated employing a trio of techniques: i) scanning electron microscopy (SEM) for high-magnification structural visualization, ii)X-ray diffraction (XRD) for atomic arrangement analysis, and iii)UV-Vis spectroscopy to confirm template molecule removal and assess potential structural changes. Frequency variation of three electrical parameters: parallel capacitance (Cpqt), impedance (Zqt), and phase angle (θpqt) have been investigated. The sensor responded linearly to QT concentrations from 10 to 50 ppm, with exceptional sensitivity (LOD: 0.035 μg/kg, LOQ: 0.116 μg/kg). To predict the amount of QT in real samples, two statistical methods: i) principal component regression (PCR), and ii) partial least squares regression (PLSR) have been applied, which exhibit high accuracy and recovery, exceeding 90% with minimal error (RMSEC: 0.0015). Additionally, the sensor demonstrated excellent selectivity with remarkable stability for QT recognition in real samples. Even after three months of use, the maximum parallel capacitance (Cpqtm) increased by only 0.4 %, highlighting minimal performance degradation over time.
- 23 July 2025
- Published by Springer Nature
- p. 63-70
Discrimination of Catechin and EGCG Through Various Tea Processing Stages Using Clustering Techniques
- 23 July 2025
- Published by Springer Nature
- p. 63-70
Discrimination of Catechin and EGCG Through Various Tea Processing Stages Using Clustering Techniques
- 23 July 2025
- Published by Springer Nature
- p. 377-388
Chemometric Analysis of Citronellal in Different Citronella Essential Oils Employing Quartz Crystal Microbalance Sensors
- 23 July 2025
- Published by Springer Nature
- p. 377-388
Chemometric Analysis of Citronellal in Different Citronella Essential Oils Employing Quartz Crystal Microbalance Sensors
- 3 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Molecular Imprinted Quartz Crystal Microbalance sensor for reliable detection of Alpha-Terpineol in various Pine Essential Oil
α-Terpineol (A-Te), a bioactive monoterpenoid, is widely used in cosmetics and aroma therapy for its appeasing fragrance and flavor. Recent studies have acknowledged its immense potential in biological applications and naturopathy. This study aims to develop a low-cost detection mechanism of A-Te using a sensitive quartz crystal microbalance (QCM) sensor, employing a highly selective molecularly imprinted polymer (MIP) of methyl methacrylate (MMA) and acrylic acid (AA). Frequency deviation of the sensor has been utilized for A-Te detection in four commercial grade pine essential oils (PEOs). This has yielded a remarkable sensitivity of 0.149 Hz/ppm with a wide linear range of (5-800) ppm. Reliability of the sensor has been assessed in terms of reproducibility and repeatability study, showcasing promising values of 90.70% and 92.32% respectively. Limit of detection (LOD) has been achieved at 1.33 ppm. Polymer characterization and surface morphology of the sensor have been analysed through fourier transform infrared spectroscopy (FTIR) and scanning electron microscope (SEM) respectively. Furthermore, responses obtained from PEO samples were correlated with conventional gas chromatographic method using principal component regression (PCR) and random forest regression (RFR) models. Notably, a high prediction accuracy (96.38%) has been achieved from PCR.
- 3 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Molecular Imprinted Quartz Crystal Microbalance sensor for reliable detection of Alpha-Terpineol in various Pine Essential Oil
α-Terpineol (A-Te), a bioactive monoterpenoid, is widely used in cosmetics and aroma therapy for its appeasing fragrance and flavor. Recent studies have acknowledged its immense potential in biological applications and naturopathy. This study aims to develop a low-cost detection mechanism of A-Te using a sensitive quartz crystal microbalance (QCM) sensor, employing a highly selective molecularly imprinted polymer (MIP) of methyl methacrylate (MMA) and acrylic acid (AA). Frequency deviation of the sensor has been utilized for A-Te detection in four commercial grade pine essential oils (PEOs). This has yielded a remarkable sensitivity of 0.149 Hz/ppm with a wide linear range of (5-800) ppm. Reliability of the sensor has been assessed in terms of reproducibility and repeatability study, showcasing promising values of 90.70% and 92.32% respectively. Limit of detection (LOD) has been achieved at 1.33 ppm. Polymer characterization and surface morphology of the sensor have been analysed through fourier transform infrared spectroscopy (FTIR) and scanning electron microscope (SEM) respectively. Furthermore, responses obtained from PEO samples were correlated with conventional gas chromatographic method using principal component regression (PCR) and random forest regression (RFR) models. Notably, a high prediction accuracy (96.38%) has been achieved from PCR.
- 3 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 16621-16627
A Molecular Imprinted Bi-Polymer Graphite Electrode Decorated With NiCo₂O₄ Nano-Cubes for Rapid Detection of Theaflavin in Black Tea
Theaflavin (TF) is a major constituent in tea and is responsible for quality profiling in terms of taste attributes. This research aims to fabricate a molecular imprinted electrode modified with nanoparticles of nickel cobalt oxide for the detection of TF in tea. The proposed electrode is prepared from a co-polymer of acrylic acid (AA) and methacrylic acid (MAA) and imprinted with TF template. The nanoparticles of nickel cobalt oxide are prepared in the laboratory and further characterized by Fourier transform infrared (FTIR) and scanning electron microscope (SEM). Cyclic and differential pulse voltammetry (DPV) is performed to study the electrochemical behavior of the electrode. The electrode shows a good detection limit of 13.89$\mu $ M and has a wide linear operating range of 80–1000$\mu $ M. The electrode is repeatable and shows satisfactory reproducibility. The proposed electrode is also employed to determine the total TF in different black tea samples by correlating with standard high-performance liquid chromatography (HPLC) values using the partial least square regression (PLSR) model and a prediction accuracy of 92.6% is obtained.- 3 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 16621-16627
A Molecular Imprinted Bi-Polymer Graphite Electrode Decorated With NiCo₂O₄ Nano-Cubes for Rapid Detection of Theaflavin in Black Tea
Theaflavin (TF) is a major constituent in tea and is responsible for quality profiling in terms of taste attributes. This research aims to fabricate a molecular imprinted electrode modified with nanoparticles of nickel cobalt oxide for the detection of TF in tea. The proposed electrode is prepared from a co-polymer of acrylic acid (AA) and methacrylic acid (MAA) and imprinted with TF template. The nanoparticles of nickel cobalt oxide are prepared in the laboratory and further characterized by Fourier transform infrared (FTIR) and scanning electron microscope (SEM). Cyclic and differential pulse voltammetry (DPV) is performed to study the electrochemical behavior of the electrode. The electrode shows a good detection limit of 13.89$\mu $ M and has a wide linear operating range of 80–1000$\mu $ M. The electrode is repeatable and shows satisfactory reproducibility. The proposed electrode is also employed to determine the total TF in different black tea samples by correlating with standard high-performance liquid chromatography (HPLC) values using the partial least square regression (PLSR) model and a prediction accuracy of 92.6% is obtained.