Xiangtian Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiangtian Deng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
He Qi
2 shared publications- Yi Zhang
Institute of Future Human Habitats, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
2 shared publications Chenxi Cheng
1 shared publicationXiaoyong Zhao
1 shared publicationYi Jiang
1 shared publicationYi Zhang
1 shared publication
Latest Publications
- 2 November 2023
- Published by Elsevier in Applied Energy
- Vol. 353
A novel operation method for renewable building by combining distributed DC energy system and deep reinforcement learning
- 2 November 2023
- Published by Elsevier in Applied Energy
- Vol. 353
A novel operation method for renewable building by combining distributed DC energy system and deep reinforcement learning
- 7 March 2023
- Published by Elsevier in Building and Environment
- Vol. 234
Multi-occupant dynamic thermal comfort monitoring robot system
- 7 March 2023
- Published by Elsevier in Building and Environment
- Vol. 234
Multi-occupant dynamic thermal comfort monitoring robot system
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 9 (21) , 21010-21024
Toward Smart Multizone HVAC Control by Combining Context-Aware System and Deep Reinforcement Learning
Building energy consumption accounts for a large figure of total energy consumption and keeps a rapid increase. Energy for heating, ventilation, and air conditioning (HVAC) is the main contribution. To save energy with maintaining comfort, control methods have been studied, including rule-based methods, model predictive control, and deep reinforcement learning (DRL). While their performance in real applications can be restricted by the highly nonstationary building environment caused by factors like weather conditions. Especially, for multizone HVAC control with multiple controllers, variation of the controller policy causes potential nonstationarity for each other. Current solutions to the nonstationarity based on model-based methods add complexity for building modeling and decrease the control efficiency. In addition, although massive data are available with the development of the Internet of Things (IoT) in smart buildings, high-level exploitation of data in the context-aware system is not yet explored to detect environment changes for smart building control. To this end, we propose a novel context-aware model-free DRL method called Trans-Context soft actor–critic (SAC) for multizone HVAC control, which combines a transformer-encoder-based context-aware system and the state-of-the-art DRL algorithm SAC. The context-aware system disentangles the nonstationarity by learning context data from IoT sensors. Besides, Trans-Context SAC is a model-free method without the need for building modeling. We evaluate Trans-Context SAC in a simulation-based case study on a multizone commercial building. Results demonstrate that Trans-Context SAC can achieve up to 15.9% of energy saving compared to other baselines with maintaining thermal comfort. Besides, Trans-Context SAC obtains the generalization for unseen environments.
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 9 (21) , 21010-21024
Toward Smart Multizone HVAC Control by Combining Context-Aware System and Deep Reinforcement Learning
Building energy consumption accounts for a large figure of total energy consumption and keeps a rapid increase. Energy for heating, ventilation, and air conditioning (HVAC) is the main contribution. To save energy with maintaining comfort, control methods have been studied, including rule-based methods, model predictive control, and deep reinforcement learning (DRL). While their performance in real applications can be restricted by the highly nonstationary building environment caused by factors like weather conditions. Especially, for multizone HVAC control with multiple controllers, variation of the controller policy causes potential nonstationarity for each other. Current solutions to the nonstationarity based on model-based methods add complexity for building modeling and decrease the control efficiency. In addition, although massive data are available with the development of the Internet of Things (IoT) in smart buildings, high-level exploitation of data in the context-aware system is not yet explored to detect environment changes for smart building control. To this end, we propose a novel context-aware model-free DRL method called Trans-Context soft actor–critic (SAC) for multizone HVAC control, which combines a transformer-encoder-based context-aware system and the state-of-the-art DRL algorithm SAC. The context-aware system disentangles the nonstationarity by learning context data from IoT sensors. Besides, Trans-Context SAC is a model-free method without the need for building modeling. We evaluate Trans-Context SAC in a simulation-based case study on a multizone commercial building. Results demonstrate that Trans-Context SAC can achieve up to 15.9% of energy saving compared to other baselines with maintaining thermal comfort. Besides, Trans-Context SAC obtains the generalization for unseen environments.