Jie Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Qiangxian Huang
Hefei University of Technology
4 shared publications - Rui-Jun Li
Hefei University of Technology
3 shared publications - Zhen-Ying Cheng
Hefei University of Technology
3 shared publications - Kuang-Chao Fan
School of Mechanical Engineering, Dalian University of Technology, Dalian, China
2 shared publications Rong-Wei Lin
2 shared publications- Ya-Xiong He
School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, China
2 shared publications
Latest Publications
- 24 November 2025
- Published by Elsevier in Precision Engineering
- Vol. 98, 63-74
Thermal error modeling and multi-objective optimization design to enhance the thermal stability of interferometers
- 24 November 2025
- Published by Elsevier in Precision Engineering
- Vol. 98, 63-74
Thermal error modeling and multi-objective optimization design to enhance the thermal stability of interferometers
- 15 July 2025
- Published by Elsevier in Precision Engineering
- Vol. 96, 533-547
Online volumetric error compensation for micro-CMMs using embedded multi-DOF (degree-of-freedom) measurement systems based on Abbe and Bryan principles
- 15 July 2025
- Published by Elsevier in Precision Engineering
- Vol. 96, 533-547
Online volumetric error compensation for micro-CMMs using embedded multi-DOF (degree-of-freedom) measurement systems based on Abbe and Bryan principles
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 30893-30902
Nanoprecision Measurement of High-Aspect-Ratio Microholes Using Sub-100-μm Tungsten Ball Tip
Microholes with diameters less than 200 μm and aspect ratios larger than 5:1 are widely used in industrial production. To measure the inner wall of these structures with nanometer accuracy, this study proposed and implemented a method using a self-developed micro-coordinate-measuring machine equipped with a tungsten probe stylus. The probe stylus has a sphere diameter of approximately 60 μm, which makes it suitable for vertical insertion into the microholes. The self-fabricated tungsten probe tip’s radius error was measured and corrected using a ruby standard sphere. The tungsten probe stylus was fixed to the probe’s elastic mechanism and then inserted into the microhole’s interior through a vision-aided guidance system. Eight points uniformly distributed on the cross section at different heights were measured, and the coordinates of the points were fitted into a circular equation using the least-squares method. The measured diameter and roundness error were obtained from the fitted equations. Experimental results show that the measurement uncertainties of the diameter and roundness error measurement are 192 and 226 nm (K = 2), respectively. This method can provide nanometer-accurate measurements of the internal dimensions of microholes and microgrooves, as well as the dimensional and morphological characteristics of their inner walls. Equipped with a needle-tip probe, it can also be used to measure the roughness of the inner wall of microstructures.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 30893-30902
Nanoprecision Measurement of High-Aspect-Ratio Microholes Using Sub-100-μm Tungsten Ball Tip
Microholes with diameters less than 200 μm and aspect ratios larger than 5:1 are widely used in industrial production. To measure the inner wall of these structures with nanometer accuracy, this study proposed and implemented a method using a self-developed micro-coordinate-measuring machine equipped with a tungsten probe stylus. The probe stylus has a sphere diameter of approximately 60 μm, which makes it suitable for vertical insertion into the microholes. The self-fabricated tungsten probe tip’s radius error was measured and corrected using a ruby standard sphere. The tungsten probe stylus was fixed to the probe’s elastic mechanism and then inserted into the microhole’s interior through a vision-aided guidance system. Eight points uniformly distributed on the cross section at different heights were measured, and the coordinates of the points were fitted into a circular equation using the least-squares method. The measured diameter and roundness error were obtained from the fitted equations. Experimental results show that the measurement uncertainties of the diameter and roundness error measurement are 192 and 226 nm (K = 2), respectively. This method can provide nanometer-accurate measurements of the internal dimensions of microholes and microgrooves, as well as the dimensional and morphological characteristics of their inner walls. Equipped with a needle-tip probe, it can also be used to measure the roughness of the inner wall of microstructures.
- 16 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Novel Compensation Method of Volumetric Errors for Micro-Coordinate Measuring Machines Using Abbe and Bryan Principles
To improve the accuracy of micro-coordinate measuring machines (CMMs) to nanometer scale, numerous hardware improvements have been studied and carried out in recent years, albeit with high costs and application limitations. Error compensation technology through software has also been applied because of its high precision, high efficiency, and low cost. A global volumetric error compensation model on the basis of the Abbe and Bryan principles for micro-CMMs is proposed in this study. The volumetric errors of the general CMMs were also analyzed, and the transmission relationship between the volumetric and geometric errors was established in the proposed model. The parameters in the model including 21 geometric errors and Abbe/Bryan offsets were measured and used to compensate for the volumetric errors. A zero-class gauge block was tested using a micro-CMM based on ISO 10360-2. With the volumetric error compensation, the standard deviations of the length measurements in the different diagonal directions were reduced by more than 65%. Thus, the effectiveness of the proposed method was established. This study provides a general modeling method and compensation techniques of volumetric errors for people involved in accuracy improvement for CMMs and machine tools.
- 16 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Novel Compensation Method of Volumetric Errors for Micro-Coordinate Measuring Machines Using Abbe and Bryan Principles
To improve the accuracy of micro-coordinate measuring machines (CMMs) to nanometer scale, numerous hardware improvements have been studied and carried out in recent years, albeit with high costs and application limitations. Error compensation technology through software has also been applied because of its high precision, high efficiency, and low cost. A global volumetric error compensation model on the basis of the Abbe and Bryan principles for micro-CMMs is proposed in this study. The volumetric errors of the general CMMs were also analyzed, and the transmission relationship between the volumetric and geometric errors was established in the proposed model. The parameters in the model including 21 geometric errors and Abbe/Bryan offsets were measured and used to compensate for the volumetric errors. A zero-class gauge block was tested using a micro-CMM based on ISO 10360-2. With the volumetric error compensation, the standard deviations of the length measurements in the different diagonal directions were reduced by more than 65%. Thus, the effectiveness of the proposed method was established. This study provides a general modeling method and compensation techniques of volumetric errors for people involved in accuracy improvement for CMMs and machine tools.