XMXianyin Mao

Xianyin Mao

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xianyin Mao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prediction Method for Mechanical Characteristic Parameters of Weak Components of 110 kV Transmission Tower under Ice-Covered Condition Based on Finite Element Simulation and Machine Learning

    by Lin Yang, Lulu Mei, Yifei Chen, Yanpeng Hao, Licheng Li, Jianrong Wu, Xianyin Mao

    Icing on transmission lines may cause damage to tower components and even lead to structural failure. Aiming at the lack of research on predicting mechanical characteristic parameters of weak components of transmission towers, and the cumbersome steps of building a finite element model (FEM), the study of prediction for mechanical characteristic parameters of weak components of towers based on a finite element simulation and machine learning is proposed. Firstly, a 110 kV transmission tower in a heavily iced area is taken as an example to establish its FEM. The locations of the weak components are analyzed, and the accuracy of FEM is verified. Secondly, meteorological and terrain parameters are considered as input parameters of the prediction model. The axial stresses and nodal displacements of four weak components are selected as output parameters. The FEM of the 110 kV transmission tower is used to obtain input and output datasets. Thirdly, five machine learning algorithms are considered to establish the prediction models for mechanical characteristic parameters of weak components, and the optimal prediction model is obtained. Finally, the accuracy of the prediction method is verified through an actual tower collapse case. The results show that ACO-BPNN is the optimal model that can accurately and quickly predict the mechanical characteristic parameters of the weak components of the transmission tower. This study can provide an early warning for the failure prediction of transmission towers in heavily iced areas, thus providing an important reference for their safe operation and maintenance.


  • Open Access

    Fabrication of Slippery Surfaces on Aluminum Alloy and Its Anti-Icing Performance in Glaze Ice

    by Bo Li, Jie Bai, Lei Fan, Xianyin Mao, Zhimin Ding, Hao Mu, Guoyong Liu, Yuan Yuan

    Slippery liquid-infused porous surfaces (SLIPS) have received growing attention as promising icephobic materials. In this study, SLIPS were prepared on aluminum alloys by combining anodization and infusion of common silicone oil. An SLIPS with low ice-adhesion strength (6 kPa) was obtained by optimizing the anodizing time parameters (10 min). In addition, the frosting process and freezing of water droplets on the as-prepared SLIPS at −10 °C were delayed for 2000 s and 4800 s, respectively. Simultaneously, the as-prepared SLIPS also exhibited excellent anti-icing performance in glaze ice, since the supercooled water drips/ice slipped from the surface. The ice weight of the as-prepared SLIPS was significantly lower than that of the bare aluminum surface and the anti-icing-fluid-coated aluminum surface, which was reduced by 38.2%–63.6% compared with the bare aluminum surface. The ice weight increased with decreased temperature and inclination angle. This work proposes a method suitable for large-area preparation of SLIPS that achieves excellent anti-icing performance and significantly reduces the weight of glaze ice.


  • Open Access

    Research on Risk Assessment and Suppression Measures for Ice-Shedding on 500 kV Compact Overhead Lines

    by Yi Wen, Yifei Chen, Jianrong Wu, Xianyin Mao, Huan Huang, Lin Yang

    Overhead line ice-shedding causes line breakage and results in electrical faults occurring between transmission lines, which seriously affects the safe operation of the power grid. In this paper, a risk assessment method for ice-shedding on 500 kV compact overhead lines is proposed. Two ratios were used to assess the discharge risk and mechanical failure risk of a line. A 500 kV compact overhead line in southern China was taken as an example, the proposed risk assessment method was used to carry out a risk assessment of the ice-shedding line with an ice thickness of 15 mm, and the suppression effects of different spacer arrangement schemes on the ice-shedding line were analyzed. The results showed that the impact coefficient of the conductor reached 1.88, the maximum jump height of the lower phase conductor reached 22.596 m, and the interphase clearance of the conductor decreased sharply when the lower phase conductor of 500 kV case line underwent full-span ice-shedding synchronously. The ice-shedding line displayed both a discharge risk and a mechanical failure risk. When interphase spacers were installed at L/3 from both ends of the span for the upper-left phase and the lower phase, the upper-right phase, and the lower phase, the impact coefficient of the line became 1.76, which was lower than the recommended value of 1.8; there was no mechanical failure risk; and the maximum jump height became 10.266 m. This study verified the effectiveness of this spacer arrangement scheme.