Xing Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xing Guo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Shengbo Sang
Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
11 shared publications - Dong Zhao
Shanxi Key Laboratory of Artificial Intelligences and Micro Nano Sensors, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan 030024, P. R. China
5 shared publications Qianqian Duan
Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
3 shared publicationsZhongyun Yuan
Shanxi Key Laboratory of Micro Nano Sensors and Artificial Intelligence Perception, College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, China
3 shared publicationsDong Zhao
Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
2 shared publicationsHaoqian Li
Department of Orthopedics, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, The Second Hospital of Shanxi Medical University, Shanxi, Taiyuan, China
2 shared publications
Latest Publications
- 17 October 2026
- Published by World Scientific Pub Co Pte Ltd in Nano
Portable Press-Driven Magnetoelastic Biosensor for Detection of Escherichia coli in Sewage
Escherichia coli (E. coli) in sewage can invade the human body via contaminated water and induce a variety of diseases, which may even cause death in severe cases. Existing detection methods are limited by high cost, high technical requirements, low sensitivity, long assay time and complicated operation procedures. Therefore, it is imperative to develop high-sensitivity biosensors capable of rapid, efficient and on-site detection of E. coli. Accordingly, this study proposes a portable press-driven magnetoelastic (ME) biosensor. The system-on-chip of the ME chip is functionalized with an antibody/E. coli immunoassay recognition-sensitive structure. The ME properties of Metglas 2826 chips enable quantitative quantification of E. coli concentration via the resonance frequency shift (RFS) responding to mass loading changes induced by antibody/E. coli immunocomplex. The portable press-driven biosensor comprises a T-shaped mold integrated with coil-wrapped reaction chambers embedded in a Metglas 2826 chip, alongside microfluidic channels and micro air chambers. This design realizes the integration of sampling and detection into one system. The developed biosensor exhibits a wide linear detection range for E. coli from 10 2 to 10 7 [Formula: see text]CFU/mL, with a detection limit of 10 2 [Formula: see text]CFU/mL. Collectively, this integrated ME sensing platform offers a low-cost, highly sensitive and portable approach for on-site detection of E. coli in sewage. With its all-in-one sampling and detection capability, the sensor demonstrates great potential for on-site pathogen screening in wastewater monitoring and E. coli contamination control.
- 17 October 2026
- Published by World Scientific Pub Co Pte Ltd in Nano
Portable Press-Driven Magnetoelastic Biosensor for Detection of Escherichia coli in Sewage
Escherichia coli (E. coli) in sewage can invade the human body via contaminated water and induce a variety of diseases, which may even cause death in severe cases. Existing detection methods are limited by high cost, high technical requirements, low sensitivity, long assay time and complicated operation procedures. Therefore, it is imperative to develop high-sensitivity biosensors capable of rapid, efficient and on-site detection of E. coli. Accordingly, this study proposes a portable press-driven magnetoelastic (ME) biosensor. The system-on-chip of the ME chip is functionalized with an antibody/E. coli immunoassay recognition-sensitive structure. The ME properties of Metglas 2826 chips enable quantitative quantification of E. coli concentration via the resonance frequency shift (RFS) responding to mass loading changes induced by antibody/E. coli immunocomplex. The portable press-driven biosensor comprises a T-shaped mold integrated with coil-wrapped reaction chambers embedded in a Metglas 2826 chip, alongside microfluidic channels and micro air chambers. This design realizes the integration of sampling and detection into one system. The developed biosensor exhibits a wide linear detection range for E. coli from 10 2 to 10 7 [Formula: see text]CFU/mL, with a detection limit of 10 2 [Formula: see text]CFU/mL. Collectively, this integrated ME sensing platform offers a low-cost, highly sensitive and portable approach for on-site detection of E. coli in sewage. With its all-in-one sampling and detection capability, the sensor demonstrates great potential for on-site pathogen screening in wastewater monitoring and E. coli contamination control.
- 28 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 14 (22) , 6963-6981
Nitric oxide-enhanced blood–brain barrier penetration and mitochondria-targeted antioxidant carbon dots for Alzheimer's disease
Therapeutic mechanisms of EMA-CDs by penetrating the BBB, inhibiting Aβ fibrillation, alleviating inflammation and clearing excessive ROS in AD.
- 28 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 14 (22) , 6963-6981
Nitric oxide-enhanced blood–brain barrier penetration and mitochondria-targeted antioxidant carbon dots for Alzheimer's disease
Therapeutic mechanisms of EMA-CDs by penetrating the BBB, inhibiting Aβ fibrillation, alleviating inflammation and clearing excessive ROS in AD.
- 28 March 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (4) , 1-10
A flexible magnetic DNA biosensor composed of AgNWs/hydrogel/PS/Fe3O4 for the detection of ASFV P72 protein gene fragment
African swine fever virus (ASFV) is a highly infectious and pathogenic DNA virus with a mortality rate of nearly 100%. Here, we developed a flexible biosensor based on a AgNWs/hydrogel/PS(polystyrene)/Fe3O4 composite film for the detection of ASFV P72 protein gene fragments. A large number of carboxyl groups in the hydrogel provide modification sites for capture probes (cp) simplifying the preparation process of the biosensor. Combined with the excellent magnetic properties of Fe3O4, the excellent electrical conductivity of silver nanowires (AgNWs) and the unique optical properties of two-dimensional photonic crystals (2DPC), the flexible biosensor can convert biological signals into optical signals and electrical signals, and the micro-deformation of the film can be verified by simple optical methods. In order to improve the sensitivity, we introduce Fe3O4 and apply an external magnetic field to amplify the thin film micro-deformation. The concentration of P72 protein gene fragment and the relative change rate of resistance showed a good linear relationship, and the linear equation is y = − 0.00126x − 0.31729; the detection limit (LOD) is as low as 0.208 μM. The composite film was used to detect real serum samples, and the recovery of the composite film fluctuated in the range 91.89 to 103.19%, indicating that the composite film has practical application potential in clinical detection of ASFV. In addition, the biosensor also shows good biocompatibility, stability, and specificity. Graphical Abstract
- 28 March 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (4) , 1-10
A flexible magnetic DNA biosensor composed of AgNWs/hydrogel/PS/Fe3O4 for the detection of ASFV P72 protein gene fragment
African swine fever virus (ASFV) is a highly infectious and pathogenic DNA virus with a mortality rate of nearly 100%. Here, we developed a flexible biosensor based on a AgNWs/hydrogel/PS(polystyrene)/Fe3O4 composite film for the detection of ASFV P72 protein gene fragments. A large number of carboxyl groups in the hydrogel provide modification sites for capture probes (cp) simplifying the preparation process of the biosensor. Combined with the excellent magnetic properties of Fe3O4, the excellent electrical conductivity of silver nanowires (AgNWs) and the unique optical properties of two-dimensional photonic crystals (2DPC), the flexible biosensor can convert biological signals into optical signals and electrical signals, and the micro-deformation of the film can be verified by simple optical methods. In order to improve the sensitivity, we introduce Fe3O4 and apply an external magnetic field to amplify the thin film micro-deformation. The concentration of P72 protein gene fragment and the relative change rate of resistance showed a good linear relationship, and the linear equation is y = − 0.00126x − 0.31729; the detection limit (LOD) is as low as 0.208 μM. The composite film was used to detect real serum samples, and the recovery of the composite film fluctuated in the range 91.89 to 103.19%, indicating that the composite film has practical application potential in clinical detection of ASFV. In addition, the biosensor also shows good biocompatibility, stability, and specificity. Graphical Abstract
- 7 March 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 13 (16) , 4830-4841
NO-producing Arg-sCNDs for combined photothermal and gas effects in cancer cell ablation
Photothermal therapy (PTT) and gas therapy (GT) were combined to enhance the antitumor effect by using the local heating of photothermal materials and the dual cytotoxicity of NO and ONOO − .
- 7 March 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 13 (16) , 4830-4841
NO-producing Arg-sCNDs for combined photothermal and gas effects in cancer cell ablation
Photothermal therapy (PTT) and gas therapy (GT) were combined to enhance the antitumor effect by using the local heating of photothermal materials and the dual cytotoxicity of NO and ONOO − .
- 12 July 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (31) , 5441-5449
Novel flexible magnetoelastic biosensor based on PDMS/FeSiB/QD composite film for the detection of African swine fever virus P72 protein
African swine fever (ASF) is a highly contagious and severe hemorrhagic disease caused by the African swine fever virus (ASFV). The continuous spread of ASFV affects the safety of the global meat supply; therefore, the establishment of sensitive and specific detection methods for ASFV has become an important hot spot in food safety. Herein, we developed a flexible magnetoelastic (ME) biosensor based on PDMS/FeSiB/QDs composite films for the detection of ASFV P72 protein. Based on the high luminescence performance of CsPbBr3 quantum dots and the excellent magnetoelastic effect of FeSiB, flexible ME biosensors convert stress signals generated by antibody–antigen-specific binding into optical and electromagnetic signals. The nanostructures covalently linked by quantum dots and PDMS provide biomodification sites for ASFV P72 antibodies, simplifying the functionalization modification process compared to the case of conventional biosensors. The deformation of the PDMS film is amplified, and the conversion of surface stress signals to electrical signals is enhanced by exposing the biosensor to a uniform magnetic field. The experimental results proved that the flexible ME biosensor has a wide linear range of 10 ng mL−1–100 μg mL−1, and the detection limit is as low as 0.079 ng mL−1. Moreover, the flexible ME biosensor also shows good stability, sensitivity and specificity, confirming the potential for early disease screening.
- 12 July 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (31) , 5441-5449
Novel flexible magnetoelastic biosensor based on PDMS/FeSiB/QD composite film for the detection of African swine fever virus P72 protein
African swine fever (ASF) is a highly contagious and severe hemorrhagic disease caused by the African swine fever virus (ASFV). The continuous spread of ASFV affects the safety of the global meat supply; therefore, the establishment of sensitive and specific detection methods for ASFV has become an important hot spot in food safety. Herein, we developed a flexible magnetoelastic (ME) biosensor based on PDMS/FeSiB/QDs composite films for the detection of ASFV P72 protein. Based on the high luminescence performance of CsPbBr3 quantum dots and the excellent magnetoelastic effect of FeSiB, flexible ME biosensors convert stress signals generated by antibody–antigen-specific binding into optical and electromagnetic signals. The nanostructures covalently linked by quantum dots and PDMS provide biomodification sites for ASFV P72 antibodies, simplifying the functionalization modification process compared to the case of conventional biosensors. The deformation of the PDMS film is amplified, and the conversion of surface stress signals to electrical signals is enhanced by exposing the biosensor to a uniform magnetic field. The experimental results proved that the flexible ME biosensor has a wide linear range of 10 ng mL−1–100 μg mL−1, and the detection limit is as low as 0.079 ng mL−1. Moreover, the flexible ME biosensor also shows good stability, sensitivity and specificity, confirming the potential for early disease screening.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
Magnetoelastic-Chip Integrated Microfluidic Biosensor for the Detection of African Swine Fever Virus
The African swine fever virus (ASFV), which is highly infectious and lethal, lacks a specific drug for treatment, resulting in the death of infected pigs. Therefore, accurate detection of the ASFV is of utmost importance. Currently, most detection methods for the ASFV primarily focus on polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA). In recent years, novel detection techniques such as double-antigen sandwich side-flow detection and fluorescent immunochromatography bands (FICTS) have emerged successively. However, these methods are intricate to operate and require expensive equipment, posing significant limitations in clinical experiments. Herein, we propose a low-cost, fast and portable magnetoelastic-chip integrated microfluidic biosensor for the detection of the ASFV. The biosensor is mainly composed of the magnetoelastic (ME) chip, an air-core coil, a reaction chamber and a microfluidic channel. It is proposed for the first time to integrate air-core coils into PDMS-based microfluidic biosensor, realizing the integration and flexibility compared to traditional ME sensors. In this experiment, 3D printing technology and microfluidic technology are used to make the prepared biosensor compact, which can realize the integration of sampling and detection, and has the advantages of less reagent consumption, low pollution level, and fast detection speed. We detect the ASFV antigen content by analyzing the resonance frequency of the ME chip that is extremely sensitive to changes in mass. The results show that the biosensor has a linear response with the logarithm of ASFV concentrations in the range of 10 pg/ml-1 mg/ml, and the detection limit (0.83pg/ml) is lower than other detection methods. In addition, the biosensor prepared in this experiment will play a great role in the detection of the ASFV, and has great potential in preventing the outbreak of the African swine fever (ASF) epidemic.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
Magnetoelastic-Chip Integrated Microfluidic Biosensor for the Detection of African Swine Fever Virus
The African swine fever virus (ASFV), which is highly infectious and lethal, lacks a specific drug for treatment, resulting in the death of infected pigs. Therefore, accurate detection of the ASFV is of utmost importance. Currently, most detection methods for the ASFV primarily focus on polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA). In recent years, novel detection techniques such as double-antigen sandwich side-flow detection and fluorescent immunochromatography bands (FICTS) have emerged successively. However, these methods are intricate to operate and require expensive equipment, posing significant limitations in clinical experiments. Herein, we propose a low-cost, fast and portable magnetoelastic-chip integrated microfluidic biosensor for the detection of the ASFV. The biosensor is mainly composed of the magnetoelastic (ME) chip, an air-core coil, a reaction chamber and a microfluidic channel. It is proposed for the first time to integrate air-core coils into PDMS-based microfluidic biosensor, realizing the integration and flexibility compared to traditional ME sensors. In this experiment, 3D printing technology and microfluidic technology are used to make the prepared biosensor compact, which can realize the integration of sampling and detection, and has the advantages of less reagent consumption, low pollution level, and fast detection speed. We detect the ASFV antigen content by analyzing the resonance frequency of the ME chip that is extremely sensitive to changes in mass. The results show that the biosensor has a linear response with the logarithm of ASFV concentrations in the range of 10 pg/ml-1 mg/ml, and the detection limit (0.83pg/ml) is lower than other detection methods. In addition, the biosensor prepared in this experiment will play a great role in the detection of the ASFV, and has great potential in preventing the outbreak of the African swine fever (ASF) epidemic.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (8) , 12017-12024
Scorpion-Inspired, Hydrophobic, Highly Sensitive, and Paper-Based Magnetoelastic Biosensor for C-Reactive Protein Detection
C-reactive protein (CRP) in human blood have crucial clinical significance as a valid biomarker for acute infection or inflammation. There is an increasing demand for paper-based magnetoelastic biosensors with water repellency and convenience for CRP detection, currently. Herein, we have developed a paper-based Magnetoelastic (ME) biosensor with hydrophobic, highly sensitive through low-cost and environmentally friendly methods. Based on inspiration from the scorpion, the V-shaped grooves were introduced into the biosensor to improve sensitivity. Photo paper(P-paper) functionalized with CoFe 2 O 4 and MWCNTs was selected as the substrate for the sensor, while PDMS was used as a sealing layer to achieve the hydrophobicity of the sensor. AuNPs/PDMS was used to provide the biomodification site for CRP antibody binding. Due to the magnetoelastic effect of CoFe 2 O 4 and the electrical conductivity of MWCNTs, surface stress generated by specific binding of CRP antigen and CRP antibody is converted into electrical and magnetic signals. The results show that the limit of detection (LOD) was 100pg/ml in the linear range from 100pg/ml to 1000ng/ml. In addition, the ME biosensor displays an outstanding performance in stability and specificity experiments.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (8) , 12017-12024
Scorpion-Inspired, Hydrophobic, Highly Sensitive, and Paper-Based Magnetoelastic Biosensor for C-Reactive Protein Detection
C-reactive protein (CRP) in human blood have crucial clinical significance as a valid biomarker for acute infection or inflammation. There is an increasing demand for paper-based magnetoelastic biosensors with water repellency and convenience for CRP detection, currently. Herein, we have developed a paper-based Magnetoelastic (ME) biosensor with hydrophobic, highly sensitive through low-cost and environmentally friendly methods. Based on inspiration from the scorpion, the V-shaped grooves were introduced into the biosensor to improve sensitivity. Photo paper(P-paper) functionalized with CoFe 2 O 4 and MWCNTs was selected as the substrate for the sensor, while PDMS was used as a sealing layer to achieve the hydrophobicity of the sensor. AuNPs/PDMS was used to provide the biomodification site for CRP antibody binding. Due to the magnetoelastic effect of CoFe 2 O 4 and the electrical conductivity of MWCNTs, surface stress generated by specific binding of CRP antigen and CRP antibody is converted into electrical and magnetic signals. The results show that the limit of detection (LOD) was 100pg/ml in the linear range from 100pg/ml to 1000ng/ml. In addition, the ME biosensor displays an outstanding performance in stability and specificity experiments.
- 27 November 2023
- Published by World Scientific Pub Co Pte Ltd in Nano
- Vol. 18 (13)
AuNPs-PDMS Composite Membrane-Based Surface Stress Biosensor for Molecular Detection
Receptor-functionalized membranes provide a new paradigm for developing mechanical biosensors. However, the lower sensitivity of these biosensors is still a challenge. In this research, a sensitive and thin (1.5 [ ]m) gold nanoparticles-polydimethylsiloxane (AuNPs-PDMS) membrane is fabricated by reducing HAuCl4. Experimental results reveal that surface stress deforms the AuNPs-PDMS membrane, further increasing the resistance due to the tunneling mechanism and conductive percolation. During the functional process, the resistance change is consistent with theoretical prediction. The relative resistance change demonstrates a linear relationship with the glucose concentration. The biosensors exhibit a wider linear range for glucose from 0 to 30[ ]mM with a lower detection limit of 0.035[ ]mM. AuNPs-PDMS thin membrane-based surface stress biosensor shows promising application prospects to detect biomolecules.
- 27 November 2023
- Published by World Scientific Pub Co Pte Ltd in Nano
- Vol. 18 (13)
AuNPs-PDMS Composite Membrane-Based Surface Stress Biosensor for Molecular Detection
Receptor-functionalized membranes provide a new paradigm for developing mechanical biosensors. However, the lower sensitivity of these biosensors is still a challenge. In this research, a sensitive and thin (1.5 [ ]m) gold nanoparticles-polydimethylsiloxane (AuNPs-PDMS) membrane is fabricated by reducing HAuCl4. Experimental results reveal that surface stress deforms the AuNPs-PDMS membrane, further increasing the resistance due to the tunneling mechanism and conductive percolation. During the functional process, the resistance change is consistent with theoretical prediction. The relative resistance change demonstrates a linear relationship with the glucose concentration. The biosensors exhibit a wider linear range for glucose from 0 to 30[ ]mM with a lower detection limit of 0.035[ ]mM. AuNPs-PDMS thin membrane-based surface stress biosensor shows promising application prospects to detect biomolecules.
- 20 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (2) , 1572-1578
Three-Dimensional Printed Flexible Magnetoelastic Biosensor for C-Reactive Protein Detection Based on Patterned PDMS/MnFe2O4 Film
For the first time, a flexible magnetoelastic (ME) biosensor with grid microstructure deposited on the PDMS/MnFe 2 O 4 film is developed for the detection of C-reactive protein (CRP), a biomarker of cardiovascular diseases (CVD) and inflammations. The patterning of flexible ME films was realized by fabricating mesh molds employing 3D printing technology, to enhance the sensitivity of the film to stress. CRP antibody, which were specifically recognized to CRP, were modified on the surface of AuNPs assembled PDMS/MnFe 2 O 4 film via gold-sulfur affinity. SEM, EDS and AFM characterization proved that the biosensor was successfully realized the surface biological functionalization modification and effectively recognized CRP. Due to the excellent magneto-electric properties of MnFe 2 O 4 nanoparticles and the superior flexibility of PDMS, the flexible ME biosensor transforms the surface stress signal induced by the specific binding of CRP and antibody modified on the film into the electromagnetic signal. The flexible ME biosensor showed wide linear range (10 ng/mL-100 μg/mL) and low detection limit (10 ng/mL), which is significantly lower than the minimal warning diagnosis limit of CVD. Some possible interfering substances were also measured for comparison, demonstrating that the biosensor possessed good selectivity. This flexible ME biosensor is applicable as an inexpensive, highly sensitive, easy-to-use and disposable method for CRP detection, providing an attractive protocol for early CVD diagnosis and postoperative monitoring.
- 20 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (2) , 1572-1578
Three-Dimensional Printed Flexible Magnetoelastic Biosensor for C-Reactive Protein Detection Based on Patterned PDMS/MnFe2O4 Film
For the first time, a flexible magnetoelastic (ME) biosensor with grid microstructure deposited on the PDMS/MnFe 2 O 4 film is developed for the detection of C-reactive protein (CRP), a biomarker of cardiovascular diseases (CVD) and inflammations. The patterning of flexible ME films was realized by fabricating mesh molds employing 3D printing technology, to enhance the sensitivity of the film to stress. CRP antibody, which were specifically recognized to CRP, were modified on the surface of AuNPs assembled PDMS/MnFe 2 O 4 film via gold-sulfur affinity. SEM, EDS and AFM characterization proved that the biosensor was successfully realized the surface biological functionalization modification and effectively recognized CRP. Due to the excellent magneto-electric properties of MnFe 2 O 4 nanoparticles and the superior flexibility of PDMS, the flexible ME biosensor transforms the surface stress signal induced by the specific binding of CRP and antibody modified on the film into the electromagnetic signal. The flexible ME biosensor showed wide linear range (10 ng/mL-100 μg/mL) and low detection limit (10 ng/mL), which is significantly lower than the minimal warning diagnosis limit of CVD. Some possible interfering substances were also measured for comparison, demonstrating that the biosensor possessed good selectivity. This flexible ME biosensor is applicable as an inexpensive, highly sensitive, easy-to-use and disposable method for CRP detection, providing an attractive protocol for early CVD diagnosis and postoperative monitoring.
- Open Access
- 7 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 401
Highly Sensitive Magnetoelastic Biosensor for Alpha2-Macroglobulin Detection Based on MnFe2O4@chitosan/MWCNTs/PDMS Composite
The need for Alpha2-Macroglobulin (α2-M) detection has increased because it plays an important role in the diagnosis of diabetic nephropathy (DN). However, few sensors can realize the high-sensitive detection for α2-M with characteristics of being fast, flexible, wearable and portable. Herein, a biosensor based on a MnFe2O4@chitosan/MWCNTs/PDMS composite film was developed for α2-M detection. Due to the excellent magnetoelastic effect of MnFe2O4 nanoparticles, the stress signal of the biosensor surface induced by the specific antibody–antigen binding was transformed into the electrical and magnetic signal. Chitosan-coated MnFe2O4 particles were used to provide biological modification sites for the α2-M antibody, which simplified the conventional biological functionalization modification process. The MnFe2O4@chitosan particles were successfully prepared by a chemical coprecipitation method and the property was studied by TEM, FT-IR and XRD. MWCNTs were employed to enhance electrical conductivity and the sensitivity of the biosensor. The detection limit (LOD) was reduced to 0.1299 ng·mL−1 in the linear range from 10 ng∙mL−1 to 100 µg·mL−1, which was significantly lower than the limit of health diagnostics. The biosensor is fabricated by a simple method, with advantages of being rapid and highly-sensitive, and having selective detection of α2-M, which provides a novel method for the early diagnosis of DN, and it has potential in the point of care (PoC) field.
- 7 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 401
Open AccessHighly Sensitive Magnetoelastic Biosensor for Alpha2-Macroglobulin Detection Based on MnFe2O4@chitosan/MWCNTs/PDMS Composite
The need for Alpha2-Macroglobulin (α2-M) detection has increased because it plays an important role in the diagnosis of diabetic nephropathy (DN). However, few sensors can realize the high-sensitive detection for α2-M with characteristics of being fast, flexible, wearable and portable. Herein, a biosensor based on a MnFe2O4@chitosan/MWCNTs/PDMS composite film was developed for α2-M detection. Due to the excellent magnetoelastic effect of MnFe2O4 nanoparticles, the stress signal of the biosensor surface induced by the specific antibody–antigen binding was transformed into the electrical and magnetic signal. Chitosan-coated MnFe2O4 particles were used to provide biological modification sites for the α2-M antibody, which simplified the conventional biological functionalization modification process. The MnFe2O4@chitosan particles were successfully prepared by a chemical coprecipitation method and the property was studied by TEM, FT-IR and XRD. MWCNTs were employed to enhance electrical conductivity and the sensitivity of the biosensor. The detection limit (LOD) was reduced to 0.1299 ng·mL−1 in the linear range from 10 ng∙mL−1 to 100 µg·mL−1, which was significantly lower than the limit of health diagnostics. The biosensor is fabricated by a simple method, with advantages of being rapid and highly-sensitive, and having selective detection of α2-M, which provides a novel method for the early diagnosis of DN, and it has potential in the point of care (PoC) field.