Yilu Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yilu Zhou has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bongmook Lee
State University of New York Polytechnic Institute 3 , Utica, New York 13502
4 shared publications - Veena Misra
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA
4 shared publications - Farzad Mohaddes
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
2 shared publications - Mahaboobbatcha Aleem
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA
2 shared publications Adam C. Curry
ASSIST Research Center, North Carolina State University, Raleigh, NC, USA
1 shared publication- Akhilesh Tanneeru
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA
1 shared publication
Latest Publications
- Open Access
- 19 December 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 268
Novel Sequential Detection of NO2 and C2H5OH in SnO2 MEMS Arrays for Enhanced Selectivity in E-Nose Applications
This study explores the surface chemistry and electrical responses of ultra-high-sensitivity SnO2 MEMS arrays to enable a novel sequential detection methodology for detecting nitrogen dioxide (NO2) and ethanol (C2H5OH) as a route to achieve selective gas sensing in electronic nose (E-nose) applications. Utilizing tin oxide (SnO2) thin films deposited via atomic layer deposition (ALD), the array achieves the lowest reported detection limits of 8 parts per billion (ppb) for NO2. The research delves into the detection mechanisms of NO2 and C2H5OH, both individually and in subsequent exposures, assessing the sensor’s dynamic response across various operating temperatures. It demonstrates rapid response and recovery times, with averages of 48 s and 277 s for NO2 and 40 and 48 for C2H5OH. Understanding the role of individual gases on the SnO2 surface chemistry is paramount in discerning subsequent gas exposure behavior. The oxidizing behavior of C2H5OH following NO2 exposure is attributed to interactions between NO2 and oxygen vacancies on the SnO2 surface, which leads to the formation of nitrate or nitrite species. These species subsequently influence interactions with C2H5OH, inducing oxidizing properties, and need to be carefully considered. Principal component analysis (PCA) was used to further improve the sensor’s capability to precisely identify and quantify gas mixtures, improving its applicability for real-time monitoring in complex scenarios.
- 19 December 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 268
Open AccessNovel Sequential Detection of NO2 and C2H5OH in SnO2 MEMS Arrays for Enhanced Selectivity in E-Nose Applications
This study explores the surface chemistry and electrical responses of ultra-high-sensitivity SnO2 MEMS arrays to enable a novel sequential detection methodology for detecting nitrogen dioxide (NO2) and ethanol (C2H5OH) as a route to achieve selective gas sensing in electronic nose (E-nose) applications. Utilizing tin oxide (SnO2) thin films deposited via atomic layer deposition (ALD), the array achieves the lowest reported detection limits of 8 parts per billion (ppb) for NO2. The research delves into the detection mechanisms of NO2 and C2H5OH, both individually and in subsequent exposures, assessing the sensor’s dynamic response across various operating temperatures. It demonstrates rapid response and recovery times, with averages of 48 s and 277 s for NO2 and 40 and 48 for C2H5OH. Understanding the role of individual gases on the SnO2 surface chemistry is paramount in discerning subsequent gas exposure behavior. The oxidizing behavior of C2H5OH following NO2 exposure is attributed to interactions between NO2 and oxygen vacancies on the SnO2 surface, which leads to the formation of nitrate or nitrite species. These species subsequently influence interactions with C2H5OH, inducing oxidizing properties, and need to be carefully considered. Principal component analysis (PCA) was used to further improve the sensor’s capability to precisely identify and quantify gas mixtures, improving its applicability for real-time monitoring in complex scenarios.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (2) , 1-4
A Novel Monolithic MEMS Array for E-Nose Applications
In this letter, we present a novel monolithic microelectromechanical syste-ms (MEMS) matrix array that can be adapted for electronic nose (E-nose) applications. The proposed MEMS array consists of four heater rows and four sensing electrode columns, arranged in crossbars and resulting in 16 intersections, which sit on top of suspended membranes created by frontside isotropic dry etching. Power supply, fine-tuning, and wireless communication are integrated on a custom printed circuit board. Thin films of metal oxide are deposited on this matrix array via atomic layer deposition. The achieved E-nose is low power, ultrasensitive, fast, scalable, reliable, and repeatable. It responds to different volatile organic compounds (VOCs) through the identification of optimal operating temperature. For nitrogen dioxide, ethanol, and carbon monoxide (CO), optimal temperatures and measured lower detection limits are ∼150 °C, 6.67 ppb, ∼250 °C, 50 ppb, and ∼350 °C, 1 ppm, respectively. Calculated theoretical detection limits are orders of magnitude lower. At optimal conditions, response/recovery time is <1 min. By tuning temperature profiles, this E-nose can inherently separate VOCs in mixtures. The proposed array is a versatile platform, compatible with back end of line complementary metal–oxide–semiconductor (CMOS) technology.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (2) , 1-4
A Novel Monolithic MEMS Array for E-Nose Applications
In this letter, we present a novel monolithic microelectromechanical syste-ms (MEMS) matrix array that can be adapted for electronic nose (E-nose) applications. The proposed MEMS array consists of four heater rows and four sensing electrode columns, arranged in crossbars and resulting in 16 intersections, which sit on top of suspended membranes created by frontside isotropic dry etching. Power supply, fine-tuning, and wireless communication are integrated on a custom printed circuit board. Thin films of metal oxide are deposited on this matrix array via atomic layer deposition. The achieved E-nose is low power, ultrasensitive, fast, scalable, reliable, and repeatable. It responds to different volatile organic compounds (VOCs) through the identification of optimal operating temperature. For nitrogen dioxide, ethanol, and carbon monoxide (CO), optimal temperatures and measured lower detection limits are ∼150 °C, 6.67 ppb, ∼250 °C, 50 ppb, and ∼350 °C, 1 ppm, respectively. Calculated theoretical detection limits are orders of magnitude lower. At optimal conditions, response/recovery time is <1 min. By tuning temperature profiles, this E-nose can inherently separate VOCs in mixtures. The proposed array is a versatile platform, compatible with back end of line complementary metal–oxide–semiconductor (CMOS) technology.
- 15 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (19) , 18970-18977
A Wearable Electrocardiography Armband Resilient Against Artifacts
Electrocardiography (ECG) is an essential technique to assess cardiovascular conditions and monitor physical activities. While the concept is mature, issues surrounding sampling convenience and device adoption as well as maintaining signal quality under artifacts remain a problem. In this article, we present a high-performing wearable ECG armband on the upper left arm. It is equipped with miniaturized hardware, capable of data storage and wireless communication. We evaluate different electrode configurations by conducting ECG measurements both at the static state and under motion and using improved algorithms to quantify data quality and assess the agreement between the proposed new technique and the gold standard. The optimal electrode position is determined by balancing wearable suitability and signal quality. We propose an electronic textile (E-textile) armband with improved design. It offers favorable wearing comfort and a fashionable appearance without sacrificing data quality. Its contact pressure is measured to get a better picture of intimacy and clothing comfort. Our system provides real-time and noise-resilient ECG data without interrupting daily life and can be implemented in use cases that warrant continuous ECG monitoring.
- 15 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (19) , 18970-18977
A Wearable Electrocardiography Armband Resilient Against Artifacts
Electrocardiography (ECG) is an essential technique to assess cardiovascular conditions and monitor physical activities. While the concept is mature, issues surrounding sampling convenience and device adoption as well as maintaining signal quality under artifacts remain a problem. In this article, we present a high-performing wearable ECG armband on the upper left arm. It is equipped with miniaturized hardware, capable of data storage and wireless communication. We evaluate different electrode configurations by conducting ECG measurements both at the static state and under motion and using improved algorithms to quantify data quality and assess the agreement between the proposed new technique and the gold standard. The optimal electrode position is determined by balancing wearable suitability and signal quality. We propose an electronic textile (E-textile) armband with improved design. It offers favorable wearing comfort and a fashionable appearance without sacrificing data quality. Its contact pressure is measured to get a better picture of intimacy and clothing comfort. Our system provides real-time and noise-resilient ECG data without interrupting daily life and can be implemented in use cases that warrant continuous ECG monitoring.
- Open Access
- 23 May 2020
- Published by MDPI AG in Electronics
- Vol. 9 (5) , 866
A Pipeline for Adaptive Filtering and Transformation of Noisy Left-Arm ECG to Its Surrogate Chest Signal
The performance of a low-power single-lead armband in generating electrocardiogram (ECG) signals from the chest and left arm was validated against a BIOPAC MP160 benchtop system in real-time. The filtering performance of three adaptive filtering algorithms, namely least mean squares (LMS), recursive least squares (RLS), and extended kernel RLS (EKRLS) in removing white (W), power line interference (PLI), electrode movement (EM), muscle artifact (MA), and baseline wandering (BLW) noises from the chest and left-arm ECG was evaluated with respect to the mean squared error (MSE). Filter parameters of the used algorithms were adjusted to ensure optimal filtering performance. LMS was found to be the most effective adaptive filtering algorithm in removing all noises with minimum MSE. However, for removing PLI with a maximal signal-to-noise ratio (SNR), RLS showed lower MSE values than LMS when the step size was set to 1 × 10−5. We proposed a transformation framework to convert the denoised left-arm and chest ECG signals to their low-MSE and high-SNR surrogate chest signals. With wide applications in wearable technologies, the proposed pipeline was found to be capable of establishing a baseline for comparing left-arm signals with original chest signals, getting one step closer to making use of the left-arm ECG in clinical cardiac evaluations.
- 23 May 2020
- Published by MDPI AG in Electronics
- Vol. 9 (5) , 866
Open AccessA Pipeline for Adaptive Filtering and Transformation of Noisy Left-Arm ECG to Its Surrogate Chest Signal
The performance of a low-power single-lead armband in generating electrocardiogram (ECG) signals from the chest and left arm was validated against a BIOPAC MP160 benchtop system in real-time. The filtering performance of three adaptive filtering algorithms, namely least mean squares (LMS), recursive least squares (RLS), and extended kernel RLS (EKRLS) in removing white (W), power line interference (PLI), electrode movement (EM), muscle artifact (MA), and baseline wandering (BLW) noises from the chest and left-arm ECG was evaluated with respect to the mean squared error (MSE). Filter parameters of the used algorithms were adjusted to ensure optimal filtering performance. LMS was found to be the most effective adaptive filtering algorithm in removing all noises with minimum MSE. However, for removing PLI with a maximal signal-to-noise ratio (SNR), RLS showed lower MSE values than LMS when the step size was set to 1 × 10−5. We proposed a transformation framework to convert the denoised left-arm and chest ECG signals to their low-MSE and high-SNR surrogate chest signals. With wide applications in wearable technologies, the proposed pipeline was found to be capable of establishing a baseline for comparing left-arm signals with original chest signals, getting one step closer to making use of the left-arm ECG in clinical cardiac evaluations.