Aharon J. Agranat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aharon J. Agranat has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Shimshon Belkin
Institute of Life Sciences The Hebrew University of Jerusalem Jerusalem Israel
3 shared publications - Yonatan Uziel
Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem 9190401, Israel
3 shared publications - Natan Orlov
Department of Applied Physics, The Hebrew University of Jerusalem, Jerusalem 9190401, Israel
2 shared publications - Andrea Perucchi
ELETTRA Sincrotrone Trieste
1 shared publication - Benjamin Shemer
Department of Plant & Environmental Sciences, Institute of Life Sciences, The Hebrew University of Jerusalem, Jerusalem 9190401, Israel
1 shared publication - Eleonora Bonaventura
Dipartimento di Scienza dei Materiali BiQuTe Università degli Studi di Milano‐Bicocca Milan Italy
1 shared publication
Latest Publications
- Open Access
- 25 September 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (10) , 539
Detection of Buried Landmines in an Active Minefield Through Bioreporter-Based Optoelectronic Sensing of Their Chemical Signatures
The research presented herein provides a first demonstration and a proof of concept of using sensing bacteria (bioreporters) to detect the chemical signatures generated by buried TNT-based landmines in an active minefield. The methodology, based on bioreporters generating a measurable signal in the presence of these chemicals, is fundamentally different from conventional approaches by detecting the explosive component of the device rather than its shape or metallic content. Furthermore, by virtue of the versatility of bioreporters to detect a broad range of target chemicals, the methodology can potentially be adapted to detect other types of explosives through the development of dedicated bioreporters. The measurements also highlight the potential of the biosensing modules to act as nodes in a sensor network for implementing the methodology across large areas. The methodology for detecting TNT via bacterial biosensing can be implemented in alternative configurations, enabling additional applications such as the identification of concealed TNT in cargo containers, buildings, and other environments.
- 25 September 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (10) , 539
Open AccessDetection of Buried Landmines in an Active Minefield Through Bioreporter-Based Optoelectronic Sensing of Their Chemical Signatures
The research presented herein provides a first demonstration and a proof of concept of using sensing bacteria (bioreporters) to detect the chemical signatures generated by buried TNT-based landmines in an active minefield. The methodology, based on bioreporters generating a measurable signal in the presence of these chemicals, is fundamentally different from conventional approaches by detecting the explosive component of the device rather than its shape or metallic content. Furthermore, by virtue of the versatility of bioreporters to detect a broad range of target chemicals, the methodology can potentially be adapted to detect other types of explosives through the development of dedicated bioreporters. The measurements also highlight the potential of the biosensing modules to act as nodes in a sensor network for implementing the methodology across large areas. The methodology for detecting TNT via bacterial biosensing can be implemented in alternative configurations, enabling additional applications such as the identification of concealed TNT in cargo containers, buildings, and other environments.
- Open Access
- 5 March 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (3) , 62
Escherichia coli Optoelectronic Sensors for In Situ Monitoring of Selected Materials Across Water Supply Systems
Chemical monitoring of pollutants and hazardous materials in water supply systems traditionally depends on centralized laboratories, advanced instrumentation, and trained personnel, limiting accessibility and preventing real-time, on-site analysis. This work presents an alternative cost-effective, field-deployable approach that uses genetically engineered bioluminescent bioreporters, encapsulated in self-sufficient alginate capsules and integrated with an optoelectronic detection circuit, to detect and quantify target materials in water. We have developed a scalable single-channel prototype featuring four sensing tracks—two for sample measurement, one for clean water, and one for a standard reference solution. The latter employs the standard ratio (SR) method to ensure robust quantification, compensating for batch variability and environmental effects. System characterization showed high uniformity across tracks. Validation with nalidixic acid (NA) demonstrated reliable quantitative performance, with a blind test estimation of 5.6 mg/L for a true concentration of 5 mg/L, well within the calibration error range. Additional sensitivity testing confirmed detection of mitomycin C (MMC) at concentrations as low as 50 µg/L. Overall, the results highlight the potential of bacterial chemical sensing as a practical and scalable tool for real-time, in situ water quality monitoring networks.
- 5 March 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (3) , 62
Open AccessEscherichia coli Optoelectronic Sensors for In Situ Monitoring of Selected Materials Across Water Supply Systems
Chemical monitoring of pollutants and hazardous materials in water supply systems traditionally depends on centralized laboratories, advanced instrumentation, and trained personnel, limiting accessibility and preventing real-time, on-site analysis. This work presents an alternative cost-effective, field-deployable approach that uses genetically engineered bioluminescent bioreporters, encapsulated in self-sufficient alginate capsules and integrated with an optoelectronic detection circuit, to detect and quantify target materials in water. We have developed a scalable single-channel prototype featuring four sensing tracks—two for sample measurement, one for clean water, and one for a standard reference solution. The latter employs the standard ratio (SR) method to ensure robust quantification, compensating for batch variability and environmental effects. System characterization showed high uniformity across tracks. Validation with nalidixic acid (NA) demonstrated reliable quantitative performance, with a blind test estimation of 5.6 mg/L for a true concentration of 5 mg/L, well within the calibration error range. Additional sensitivity testing confirmed detection of mitomycin C (MMC) at concentrations as low as 50 µg/L. Overall, the results highlight the potential of bacterial chemical sensing as a practical and scalable tool for real-time, in situ water quality monitoring networks.
- Open Access
- 11 October 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (10) , 207
Quantitative Chemical Sensing Using Genetically Engineered Bacterial Bioreporters
We present a generic quantitative chemical sensing methodology for assessing the concentration of a target material (TM) in an aqueous solution by using bioluminescent microbial bioreporters as the core sensing elements. Such bioreporters, genetically engineered to respond to the presence of a TM in their microenvironment by emitting bioluminescence, have previously been mostly designed to report the presence or absence of the TM in the sample. We extend this methodology to also assess the TM concentration, by exploiting the dose-dependency of the TM-induced luminescence. To overcome luminescence intensity variations due to bacterial batch differences and the ambient temperature, simultaneous measurements were carried out on sample solutions containing known concentrations of the TM. A “standard ratio” parameter, defined as the ratio between the two measurements, is shown to be independent of the bacterial batch and the temperature, and hence provides the conceptual basis for a generic quantitative chemical sensing methodology. Assessment of 2,4-dinitrotoluene (DNT) concentration in solutions is demonstrated with an accuracy of 2.5% over a wide dynamic range.
- 11 October 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (10) , 207
Open AccessQuantitative Chemical Sensing Using Genetically Engineered Bacterial Bioreporters
We present a generic quantitative chemical sensing methodology for assessing the concentration of a target material (TM) in an aqueous solution by using bioluminescent microbial bioreporters as the core sensing elements. Such bioreporters, genetically engineered to respond to the presence of a TM in their microenvironment by emitting bioluminescence, have previously been mostly designed to report the presence or absence of the TM in the sample. We extend this methodology to also assess the TM concentration, by exploiting the dose-dependency of the TM-induced luminescence. To overcome luminescence intensity variations due to bacterial batch differences and the ambient temperature, simultaneous measurements were carried out on sample solutions containing known concentrations of the TM. A “standard ratio” parameter, defined as the ratio between the two measurements, is shown to be independent of the bacterial batch and the temperature, and hence provides the conceptual basis for a generic quantitative chemical sensing methodology. Assessment of 2,4-dinitrotoluene (DNT) concentration in solutions is demonstrated with an accuracy of 2.5% over a wide dynamic range.
- Open Access
- 27 August 2024
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 12, 1-6
An electro-optic KLTN refractive index gradient deflector implemented in an actively Q-switched Tm:YLF laser
A novel electro-optic deflector based on a quadratic electro-optical potassium lithium tantalate niobate (KLTN) crystal operating slightly above the ferroelectric phase transition is presented. The new deflection scheme was based on the electric field gradient generation along the vertical axis caused by the trapezoidal geometry of the crystal. A deflection angle of 6.5 mrad was attained for a low voltage of 680 V. The deflector was used as an electro-optic modulator for implementing active Q-switching in a thulium-doped yttrium lithium fluoride (Tm:YLF) laser (1880 nm). The laser was operated at three different repetition rates of 0.4, 0.5 and 0.7 kHz, and reached high energies per pulse up to 6.9 mJ.
- 27 August 2024
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 12, 1-6
Open AccessAn electro-optic KLTN refractive index gradient deflector implemented in an actively Q-switched Tm:YLF laser
A novel electro-optic deflector based on a quadratic electro-optical potassium lithium tantalate niobate (KLTN) crystal operating slightly above the ferroelectric phase transition is presented. The new deflection scheme was based on the electric field gradient generation along the vertical axis caused by the trapezoidal geometry of the crystal. A deflection angle of 6.5 mrad was attained for a low voltage of 680 V. The deflector was used as an electro-optic modulator for implementing active Q-switching in a thulium-doped yttrium lithium fluoride (Tm:YLF) laser (1880 nm). The laser was operated at three different repetition rates of 0.4, 0.5 and 0.7 kHz, and reached high energies per pulse up to 6.9 mJ.
- Open Access
- 27 February 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (5) , 899
Anomalous Optical Properties of KTN:Li Ferroelectric Supercrystals
We report a spectroscopic investigation of potassium–lithium–tantalate–niobate (KTN:Li) across its room-temperature ferroelectric phase transition, when the sample manifests a supercrystal phase. Reflection and transmission results indicate an unexpected temperature-dependent enhancement of average index of refraction from 450 nm to 1100 nm, with no appreciable accompanying increase in absorption. Second-harmonic generation and phase-contrast imaging indicate that the enhancement is correlated to ferroelectric domains and highly localized at the supercrystal lattice sites. Implementing a two-component effective medium model, the response of each lattice site is found to be compatible with giant broadband refraction.
- 27 February 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (5) , 899
Open AccessAnomalous Optical Properties of KTN:Li Ferroelectric Supercrystals
We report a spectroscopic investigation of potassium–lithium–tantalate–niobate (KTN:Li) across its room-temperature ferroelectric phase transition, when the sample manifests a supercrystal phase. Reflection and transmission results indicate an unexpected temperature-dependent enhancement of average index of refraction from 450 nm to 1100 nm, with no appreciable accompanying increase in absorption. Second-harmonic generation and phase-contrast imaging indicate that the enhancement is correlated to ferroelectric domains and highly localized at the supercrystal lattice sites. Implementing a two-component effective medium model, the response of each lattice site is found to be compatible with giant broadband refraction.