David Müller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
David Müller has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Anna Maria Becker
Dienstleistungszentrum Ländlicher Raum (DLR) Rheinpfalz, Institute for Viticulture and Oenology, Breitenweg 71, 67435 Neustadt an der Weinstraße - Kaiserslautern University of Technology, Department of Chemistry, Erwin-Schrödinger-Straße 52, 67663 Kaiserslautern
1 shared publication - Jens Schuster
Department of Applied Logistics and Polymer Sciences, University of Applied Sciences Kaiserslautern, 66953 Pirmasens, Germany
1 shared publication - Jochen Vestner
Institute for Viticulture and Oenology, Dienstleistungszentrum Ländlicher Raum DLR Rheinpfalz, Breitenweg 71, 67435 Neustadt/Weinstraße, Germany
1 shared publication - Jörg Gottmann
Dienstleistungszentrum Landlicher Raum DLR Rheinpf, Inst Viticulture & Oenol, Breitenweg 71, D-67435 Neustadt, Germany
1 shared publication - Ulrich Fischer
Dienstleistungszentrum Ländlicher Raum (DLR) Rheinpfalz, Institute for Viticulture and Enology
1 shared publication
Latest Publications
- Open Access
- 28 September 2022
- Published by Universite de Bordeaux in OENO One
- Vol. 56 (4) , 41-54
Improved sealing polymers and cleaning procedures to mitigate aroma carryover during bottling of aromatised and regular wines on the same filling line
Bottling of aromatised wines and regular table wines often takes place on the same bottling line. Installed sealings in the bottling line absorb volatiles from aromatised wines and, due to inadequate cleaning, carryover occurs into the subsequently bottled regular wine. This unintentional carryover can lead to accusations of illegal flavouring of wine. To minimise the carryover risk, sealing materials that absorb less volatiles are beneficial. Incorporating kaolin and micro-cellulose into the ethylene propylene diene monomer rubber (EPDM) network decreased absorption of the critical α-ionone by 51 and 60 %, respectively.Besides the minimisation of the absorption, a performed cleaning can reduce aroma carryover. So far, knowledge about cleaning parameters that can increase cleaning efficiency is limited since cleaning usually focuses on surficial removal and prevents microbiological cross-contamination. An evaluation of the cleaning parameters, temperature, time and agents clearly revealed a high factor in the considered temperature. The highest cleaning efficiency was seen at 85 °C, whereas the cleaning additives such as citric acid, caustic soda, ozone or dissolved carbon dioxide had no impact. High proportions of the aroma compounds were removed from the polymer in the first 20 min at 85 °C, but none of the performed cleaning sequences was able to remove all compounds.
- 28 September 2022
- Published by Universite de Bordeaux in OENO One
- Vol. 56 (4) , 41-54
Open AccessImproved sealing polymers and cleaning procedures to mitigate aroma carryover during bottling of aromatised and regular wines on the same filling line
Bottling of aromatised wines and regular table wines often takes place on the same bottling line. Installed sealings in the bottling line absorb volatiles from aromatised wines and, due to inadequate cleaning, carryover occurs into the subsequently bottled regular wine. This unintentional carryover can lead to accusations of illegal flavouring of wine. To minimise the carryover risk, sealing materials that absorb less volatiles are beneficial. Incorporating kaolin and micro-cellulose into the ethylene propylene diene monomer rubber (EPDM) network decreased absorption of the critical α-ionone by 51 and 60 %, respectively.Besides the minimisation of the absorption, a performed cleaning can reduce aroma carryover. So far, knowledge about cleaning parameters that can increase cleaning efficiency is limited since cleaning usually focuses on surficial removal and prevents microbiological cross-contamination. An evaluation of the cleaning parameters, temperature, time and agents clearly revealed a high factor in the considered temperature. The highest cleaning efficiency was seen at 85 °C, whereas the cleaning additives such as citric acid, caustic soda, ozone or dissolved carbon dioxide had no impact. High proportions of the aroma compounds were removed from the polymer in the first 20 min at 85 °C, but none of the performed cleaning sequences was able to remove all compounds.