Dale Kernot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dale Kernot has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Hari Arora
School of Engineering and Applied Sciences, Faculty of Science and Engineering, Swansea University, Swansea, UK
1 shared publicationJimmy Yang
Olympus Surgical Technologies Europe, Cardiff, UK
1 shared publicationNicholas Williams
Olympus Surgical Technologies Europe, Cardiff, UK
1 shared publicationPaul Ledger
School of Computing and Mathematics, Keele University, Keele, UK
1 shared publicationRaoul van Loon
School of Engineering and Applied Sciences, Faculty of Science and Engineering, Swansea University, Swansea, UK
1 shared publicationTudor Thomas
Olympus Surgical Technologies Europe, Cardiff, UK
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Swansea University
Transient Computational Analysis to Aid Microwave Ablation Device Design for Liver Tissue
Microwave ablation (MWA) therapy, a minimally invasive approach utilizing electromagnetic waves to induce cytotoxic temperatures within tumors, is the focus of this thesis. This thesis gives a comprehensive background of the theory underpinning established computational models and uses these models to perform a novel comparative analysis of various 2D MWA probe designs and to explore the efficacy of internally cooled probes. The aim is to enhance the knowledge of MWA by providing a detailed understanding of probe-tissue interactions. The initial segment of the research uses a two-dimensional axisymmetric finite element model to systematically examine different MWA probe geometries. This study specifically addresses the changes in dielectric properties of tissues at elevated temperatures and their impact on the thermal and electric field distributions. Highlighting the importance of their consideration in modelling of MWA and the transient influence they have on the shape and size of ablation fields. The second part of the thesis presents a detailed parametric study of internally cooled MWA probes. This study examines the effects of coolant system configuration, including the internal position of the cooling system, coolant flow rate, and coolant temperature on the probe’s performance. These factors are critically analyzed to determine their influence on maintaining targeted tissue heating, preventing excessive heating, and potential damage to surrounding healthy tissues. This thesis demonstrates the creation of a custom multiphysics model for microwave ablation, developed using the open-source NGSolve software. This approach enabled precise modeling of complex probe-tissue interactions, illustrating the power of open-source tools in advancing medical device research.
- 1 January 2025
- Published by Swansea University
Open AccessTransient Computational Analysis to Aid Microwave Ablation Device Design for Liver Tissue
Microwave ablation (MWA) therapy, a minimally invasive approach utilizing electromagnetic waves to induce cytotoxic temperatures within tumors, is the focus of this thesis. This thesis gives a comprehensive background of the theory underpinning established computational models and uses these models to perform a novel comparative analysis of various 2D MWA probe designs and to explore the efficacy of internally cooled probes. The aim is to enhance the knowledge of MWA by providing a detailed understanding of probe-tissue interactions. The initial segment of the research uses a two-dimensional axisymmetric finite element model to systematically examine different MWA probe geometries. This study specifically addresses the changes in dielectric properties of tissues at elevated temperatures and their impact on the thermal and electric field distributions. Highlighting the importance of their consideration in modelling of MWA and the transient influence they have on the shape and size of ablation fields. The second part of the thesis presents a detailed parametric study of internally cooled MWA probes. This study examines the effects of coolant system configuration, including the internal position of the cooling system, coolant flow rate, and coolant temperature on the probe’s performance. These factors are critically analyzed to determine their influence on maintaining targeted tissue heating, preventing excessive heating, and potential damage to surrounding healthy tissues. This thesis demonstrates the creation of a custom multiphysics model for microwave ablation, developed using the open-source NGSolve software. This approach enabled precise modeling of complex probe-tissue interactions, illustrating the power of open-source tools in advancing medical device research.
- Open Access
- 26 October 2022
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (1) , 271-280
Transient changes during microwave ablation simulation : a comparative shape analysis
Microwave ablation therapy is a hyperthermic treatment for killing cancerous tumours whereby microwave energy is dispersed into a target tissue region. Modelling can provide a prediction for the outcome of ablation, this paper explores changes in size and shape of temperature and Specific absorption rate fields throughout the course of simulated treatment with different probe concepts. Here, an axisymmetric geometry of a probe embedded within a tissue material is created, solving coupled electromagnetic and bioheat equations using the finite element method, utilizing hp discretisation with the NGSolve library. Results show dynamic changes across all metrics, with different responses from different probe concepts. The sleeve probe yielded the most circular specific absorption rate pattern with circularity of 0.81 initially but suffered the largest reduction throughout ablation. Similarly, reflection coefficients differ drastically from their initial values, with the sleeve probe again experiencing the largest change, suggesting that it is the most sensitive the changes in the tissue dielectric properties in these select probe designs. These collective characteristic observations highlight the need to consider dielectric property changes and probe specific responses during the design cycle.
- 26 October 2022
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (1) , 271-280
Open AccessTransient changes during microwave ablation simulation : a comparative shape analysis
Microwave ablation therapy is a hyperthermic treatment for killing cancerous tumours whereby microwave energy is dispersed into a target tissue region. Modelling can provide a prediction for the outcome of ablation, this paper explores changes in size and shape of temperature and Specific absorption rate fields throughout the course of simulated treatment with different probe concepts. Here, an axisymmetric geometry of a probe embedded within a tissue material is created, solving coupled electromagnetic and bioheat equations using the finite element method, utilizing hp discretisation with the NGSolve library. Results show dynamic changes across all metrics, with different responses from different probe concepts. The sleeve probe yielded the most circular specific absorption rate pattern with circularity of 0.81 initially but suffered the largest reduction throughout ablation. Similarly, reflection coefficients differ drastically from their initial values, with the sleeve probe again experiencing the largest change, suggesting that it is the most sensitive the changes in the tissue dielectric properties in these select probe designs. These collective characteristic observations highlight the need to consider dielectric property changes and probe specific responses during the design cycle.