Sandra Collette
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sandra Collette has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Emma Geertruida Elisabeth de Vries
Department of Medical Oncology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
6 shared publications - Erich P. Huang
Biometric Research Program, National Cancer Institute, Rockville, MD
6 shared publications - Jan Bogaerts
EORTC, Brussels, Belgium
6 shared publications - Lalitha K. Shankar
NCI Cancer Imaging Program, 9609 Medical Center Dr, Bethesda, MD 20892-9725
6 shared publications Larry Schwartz
6 shared publications- Lesley Seymour
Canadian Cancer Trials Group, Queens University, Kingston, ON, Canada
6 shared publications
Latest Publications
- Open Access
- 25 November 2025
- Published by American Association for Cancer Research (AACR)
Data from Meta-Analysis of the Test–Retest Repeatability of [18F]-Fluorodeoxyglucose Standardized Uptake Values: Implications for Assessment of Tumor Response
Purpose:Currently, guidelines for PET with 18F-fluorodeoxyglucose (FDG-PET) interpretation for assessment of therapy response in oncology primarily involve visual evaluation of FDG-PET/CT scans. However, quantitative measurements of the metabolic activity in tumors may be even more useful in evaluating response to treatment. Guidelines based on such measurements, including the European Organization for Research and Treatment of Cancer Criteria and PET Response Criteria in Solid Tumors, have been proposed. However, more rigorous analysis of response criteria based on FDG-PET measurements is needed to adopt regular use in practice.Experimental Design:Well-defined boundaries of repeatability and reproducibility of quantitative measurements to discriminate noise from true signal changes are a needed initial step. An extension of the meta-analysis from de Langen and colleagues (2012) of the test–retest repeatability of quantitative FDG-PET measurements, including mean, maximum, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively), was performed. Data from 11 studies in the literature were used to estimate the relationship between the variance in test–retest measurements with uptake level and various study-level, patient-level, and lesion-level characteristics.Results:Test–retest repeatability of percentage fluctuations for all three types of SUV measurement (max, mean, and peak) improved with higher FDG uptake levels. Repeatability in all three SUV measurements varied for different lesion locations. Worse repeatability in SUVmean was also associated with higher tumor volumes.Conclusions:On the basis of these results, recommendations regarding SUV measurements for assessing minimal detectable changes based on repeatability and reproducibility are proposed. These should be applied to differentiate between response categories for a future set of FDG-PET–based criteria that assess clinically significant changes in tumor response.
- 25 November 2025
- Published by American Association for Cancer Research (AACR)
Open AccessData from Meta-Analysis of the Test–Retest Repeatability of [18F]-Fluorodeoxyglucose Standardized Uptake Values: Implications for Assessment of Tumor Response
Purpose:Currently, guidelines for PET with 18F-fluorodeoxyglucose (FDG-PET) interpretation for assessment of therapy response in oncology primarily involve visual evaluation of FDG-PET/CT scans. However, quantitative measurements of the metabolic activity in tumors may be even more useful in evaluating response to treatment. Guidelines based on such measurements, including the European Organization for Research and Treatment of Cancer Criteria and PET Response Criteria in Solid Tumors, have been proposed. However, more rigorous analysis of response criteria based on FDG-PET measurements is needed to adopt regular use in practice.Experimental Design:Well-defined boundaries of repeatability and reproducibility of quantitative measurements to discriminate noise from true signal changes are a needed initial step. An extension of the meta-analysis from de Langen and colleagues (2012) of the test–retest repeatability of quantitative FDG-PET measurements, including mean, maximum, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively), was performed. Data from 11 studies in the literature were used to estimate the relationship between the variance in test–retest measurements with uptake level and various study-level, patient-level, and lesion-level characteristics.Results:Test–retest repeatability of percentage fluctuations for all three types of SUV measurement (max, mean, and peak) improved with higher FDG uptake levels. Repeatability in all three SUV measurements varied for different lesion locations. Worse repeatability in SUVmean was also associated with higher tumor volumes.Conclusions:On the basis of these results, recommendations regarding SUV measurements for assessing minimal detectable changes based on repeatability and reproducibility are proposed. These should be applied to differentiate between response categories for a future set of FDG-PET–based criteria that assess clinically significant changes in tumor response.
- Open Access
- 22 September 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 213, 111141
Radiotherapy quality assurance of the prospective randomised EORTC-1219/DAHANCA-29 trial: an individual case review analysis
- 22 September 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 213, 111141
Open AccessRadiotherapy quality assurance of the prospective randomised EORTC-1219/DAHANCA-29 trial: an individual case review analysis
- Open Access
- 1 April 2023
- Published by American Association for Cancer Research (AACR)
Data from Meta-Analysis of the Test–Retest Repeatability of [18F]-Fluorodeoxyglucose Standardized Uptake Values: Implications for Assessment of Tumor Response
Purpose:Currently, guidelines for PET with 18F-fluorodeoxyglucose (FDG-PET) interpretation for assessment of therapy response in oncology primarily involve visual evaluation of FDG-PET/CT scans. However, quantitative measurements of the metabolic activity in tumors may be even more useful in evaluating response to treatment. Guidelines based on such measurements, including the European Organization for Research and Treatment of Cancer Criteria and PET Response Criteria in Solid Tumors, have been proposed. However, more rigorous analysis of response criteria based on FDG-PET measurements is needed to adopt regular use in practice.Experimental Design:Well-defined boundaries of repeatability and reproducibility of quantitative measurements to discriminate noise from true signal changes are a needed initial step. An extension of the meta-analysis from de Langen and colleagues (2012) of the test–retest repeatability of quantitative FDG-PET measurements, including mean, maximum, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively), was performed. Data from 11 studies in the literature were used to estimate the relationship between the variance in test–retest measurements with uptake level and various study-level, patient-level, and lesion-level characteristics.Results:Test–retest repeatability of percentage fluctuations for all three types of SUV measurement (max, mean, and peak) improved with higher FDG uptake levels. Repeatability in all three SUV measurements varied for different lesion locations. Worse repeatability in SUVmean was also associated with higher tumor volumes.Conclusions:On the basis of these results, recommendations regarding SUV measurements for assessing minimal detectable changes based on repeatability and reproducibility are proposed. These should be applied to differentiate between response categories for a future set of FDG-PET–based criteria that assess clinically significant changes in tumor response.
- 1 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessData from Meta-Analysis of the Test–Retest Repeatability of [18F]-Fluorodeoxyglucose Standardized Uptake Values: Implications for Assessment of Tumor Response
Purpose:Currently, guidelines for PET with 18F-fluorodeoxyglucose (FDG-PET) interpretation for assessment of therapy response in oncology primarily involve visual evaluation of FDG-PET/CT scans. However, quantitative measurements of the metabolic activity in tumors may be even more useful in evaluating response to treatment. Guidelines based on such measurements, including the European Organization for Research and Treatment of Cancer Criteria and PET Response Criteria in Solid Tumors, have been proposed. However, more rigorous analysis of response criteria based on FDG-PET measurements is needed to adopt regular use in practice.Experimental Design:Well-defined boundaries of repeatability and reproducibility of quantitative measurements to discriminate noise from true signal changes are a needed initial step. An extension of the meta-analysis from de Langen and colleagues (2012) of the test–retest repeatability of quantitative FDG-PET measurements, including mean, maximum, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively), was performed. Data from 11 studies in the literature were used to estimate the relationship between the variance in test–retest measurements with uptake level and various study-level, patient-level, and lesion-level characteristics.Results:Test–retest repeatability of percentage fluctuations for all three types of SUV measurement (max, mean, and peak) improved with higher FDG uptake levels. Repeatability in all three SUV measurements varied for different lesion locations. Worse repeatability in SUVmean was also associated with higher tumor volumes.Conclusions:On the basis of these results, recommendations regarding SUV measurements for assessing minimal detectable changes based on repeatability and reproducibility are proposed. These should be applied to differentiate between response categories for a future set of FDG-PET–based criteria that assess clinically significant changes in tumor response.
- 27 October 2022
- Published by American Association for Cancer Research (AACR) in Clinical Cancer Research
- Vol. 29 (1) , 143-153
Meta-Analysis of the Test–Retest Repeatability of [18F]-Fluorodeoxyglucose Standardized Uptake Values: Implications for Assessment of Tumor Response
Purpose: Currently, guidelines for PET with 18F-fluorodeoxyglucose (FDG-PET) interpretation for assessment of therapy response in oncology primarily involve visual evaluation of FDG-PET/CT scans. However, quantitative measurements of the metabolic activity in tumors may be even more useful in evaluating response to treatment. Guidelines based on such measurements, including the European Organization for Research and Treatment of Cancer Criteria and PET Response Criteria in Solid Tumors, have been proposed. However, more rigorous analysis of response criteria based on FDG-PET measurements is needed to adopt regular use in practice. Experimental Design: Well-defined boundaries of repeatability and reproducibility of quantitative measurements to discriminate noise from true signal changes are a needed initial step. An extension of the meta-analysis from de Langen and colleagues (2012) of the test–retest repeatability of quantitative FDG-PET measurements, including mean, maximum, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively), was performed. Data from 11 studies in the literature were used to estimate the relationship between the variance in test–retest measurements with uptake level and various study-level, patient-level, and lesion-level characteristics. Results: Test–retest repeatability of percentage fluctuations for all three types of SUV measurement (max, mean, and peak) improved with higher FDG uptake levels. Repeatability in all three SUV measurements varied for different lesion locations. Worse repeatability in SUVmean was also associated with higher tumor volumes. Conclusions: On the basis of these results, recommendations regarding SUV measurements for assessing minimal detectable changes based on repeatability and reproducibility are proposed. These should be applied to differentiate between response categories for a future set of FDG-PET–based criteria that assess clinically significant changes in tumor response.
- 27 October 2022
- Published by American Association for Cancer Research (AACR) in Clinical Cancer Research
- Vol. 29 (1) , 143-153
Meta-Analysis of the Test–Retest Repeatability of [18F]-Fluorodeoxyglucose Standardized Uptake Values: Implications for Assessment of Tumor Response
Purpose: Currently, guidelines for PET with 18F-fluorodeoxyglucose (FDG-PET) interpretation for assessment of therapy response in oncology primarily involve visual evaluation of FDG-PET/CT scans. However, quantitative measurements of the metabolic activity in tumors may be even more useful in evaluating response to treatment. Guidelines based on such measurements, including the European Organization for Research and Treatment of Cancer Criteria and PET Response Criteria in Solid Tumors, have been proposed. However, more rigorous analysis of response criteria based on FDG-PET measurements is needed to adopt regular use in practice. Experimental Design: Well-defined boundaries of repeatability and reproducibility of quantitative measurements to discriminate noise from true signal changes are a needed initial step. An extension of the meta-analysis from de Langen and colleagues (2012) of the test–retest repeatability of quantitative FDG-PET measurements, including mean, maximum, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively), was performed. Data from 11 studies in the literature were used to estimate the relationship between the variance in test–retest measurements with uptake level and various study-level, patient-level, and lesion-level characteristics. Results: Test–retest repeatability of percentage fluctuations for all three types of SUV measurement (max, mean, and peak) improved with higher FDG uptake levels. Repeatability in all three SUV measurements varied for different lesion locations. Worse repeatability in SUVmean was also associated with higher tumor volumes. Conclusions: On the basis of these results, recommendations regarding SUV measurements for assessing minimal detectable changes based on repeatability and reproducibility are proposed. These should be applied to differentiate between response categories for a future set of FDG-PET–based criteria that assess clinically significant changes in tumor response.
- Open Access
- 6 November 2017
- Published by Oxford University Press (OUP) in Neuro-Oncology
- Vol. 19 (suppl_6) , vi48
CMET-43. COMPARISON OF LOCAL CONTROL OF BRAIN METASTASES WITH STEREOTACTIC RADIOSURGERY VERSUS SURGICAL RESECTION: A SECONDARY ANALYSIS OF EORTC 22952–26001
We sought to evaluate local control of brain metastases among patients treated with stereotactic radiosurgery (SRS) versus neurosurgical resection within EORTC 22952. We performed a post-hoc analysis of EORTC 22952 and included patients treated per-protocol who had 1–2 brain metastases <4 cm. The primary endpoint was local recurrence (previously treated site) defined from time of randomization. We compared modality-specific local control by calculating cumulative incidence of local recurrence and used competing risk regression to adjust for prognostic factors/competing mortality. Of 268 patients analyzed, 57.5% underwent SRS and 42.5% underwent surgical resection. Median follow-up was 13.5months. Compared to SRS, patients undergoing surgery had larger tumors (median 20mm vs. 28mm,p<0.001), more single brain metastases (74% vs. 98%,p<0.001), and different locations (p<0.001). Overall, SRS was associated with improved local control (p=0.015) in unadjusted analyses, but absolute differences in local control decreased with time (p= 9months, local control appeared superior for surgery: 0.36[0.14–0.93]. Increased risk of local recurrence was also associated with increasing tumor size (p=0.031) and absence of extracranial disease (p=0.044). In this exploratory analysis, SRS appeared associated with improved early local control of treated lesions compared to patients treated surgically, although the relative benefit decreased with time. Variation in baseline patient characteristics limit this analysis warranting further study.
- 6 November 2017
- Published by Oxford University Press (OUP) in Neuro-Oncology
- Vol. 19 (suppl_6) , vi48
Open AccessCMET-43. COMPARISON OF LOCAL CONTROL OF BRAIN METASTASES WITH STEREOTACTIC RADIOSURGERY VERSUS SURGICAL RESECTION: A SECONDARY ANALYSIS OF EORTC 22952–26001
We sought to evaluate local control of brain metastases among patients treated with stereotactic radiosurgery (SRS) versus neurosurgical resection within EORTC 22952. We performed a post-hoc analysis of EORTC 22952 and included patients treated per-protocol who had 1–2 brain metastases <4 cm. The primary endpoint was local recurrence (previously treated site) defined from time of randomization. We compared modality-specific local control by calculating cumulative incidence of local recurrence and used competing risk regression to adjust for prognostic factors/competing mortality. Of 268 patients analyzed, 57.5% underwent SRS and 42.5% underwent surgical resection. Median follow-up was 13.5months. Compared to SRS, patients undergoing surgery had larger tumors (median 20mm vs. 28mm,p<0.001), more single brain metastases (74% vs. 98%,p<0.001), and different locations (p<0.001). Overall, SRS was associated with improved local control (p=0.015) in unadjusted analyses, but absolute differences in local control decreased with time (p= 9months, local control appeared superior for surgery: 0.36[0.14–0.93]. Increased risk of local recurrence was also associated with increasing tumor size (p=0.031) and absence of extracranial disease (p=0.044). In this exploratory analysis, SRS appeared associated with improved early local control of treated lesions compared to patients treated surgically, although the relative benefit decreased with time. Variation in baseline patient characteristics limit this analysis warranting further study.
- 1 August 2011
- Published by Wolters Kluwer Health in Melanoma Research
- Vol. 21 (4) , 344-351
Changes of ferritin and CRP levels in melanoma patients treated with adjuvant interferon-α (EORTC 18 952) and prognostic value on treatment outcome
Adjuvant therapy with interferon-α (IFN) only benefits a small subgroup of melanoma patients and a predictive marker selecting responders does not exist. IFN induces increased ferritin and decreased C-reactive protein (CRP) levels; however, an association with treatment effect was not studied. Serum was collected from patients participating in the European Organization for Research and Treatment of Cancer 18 952 trial comparing adjuvant treatment with IFN to observation. Serial ferritin and CRP levels were determined using enzyme-linked immunosorbent assays, before treatment and up to 24 months. Ferritin levels are influenced by sex and age; therefore ratios of serial ferritin and CRP values with corresponding pretreatment values were calculated. Cox regression model and landmark method at end of induction and 6 months were used to evaluate the association between ferritin, CRP and distant metastasis-free survival (DMFS). Baseline ferritin levels were comparable in the two treatment groups (P=0.92). However, ferritin ratios were significantly higher in IFN-treated patients (N=96) compared with untreated patients (N=21) at end of induction (mean: 2.88 vs. 0.75; P=0.0003) and at 6 months (mean: 3.18 vs. 1.02; P=0.009). In the IFN arm, higher ferritin ratios at end of induction and at 6 months were not associated with improved outcome (respectively, P=0.66 and 0.86). Concerning CRP ratios, no differences between the treatment groups, neither an association with DMFS, were observed. Administration of IFN in melanoma patients induced increase in ferritin levels but not in CRP levels. Ferritin and CRP ratios have no prognostic value regarding DMFS.
- 1 August 2011
- Published by Wolters Kluwer Health in Melanoma Research
- Vol. 21 (4) , 344-351
Changes of ferritin and CRP levels in melanoma patients treated with adjuvant interferon-α (EORTC 18 952) and prognostic value on treatment outcome
Adjuvant therapy with interferon-α (IFN) only benefits a small subgroup of melanoma patients and a predictive marker selecting responders does not exist. IFN induces increased ferritin and decreased C-reactive protein (CRP) levels; however, an association with treatment effect was not studied. Serum was collected from patients participating in the European Organization for Research and Treatment of Cancer 18 952 trial comparing adjuvant treatment with IFN to observation. Serial ferritin and CRP levels were determined using enzyme-linked immunosorbent assays, before treatment and up to 24 months. Ferritin levels are influenced by sex and age; therefore ratios of serial ferritin and CRP values with corresponding pretreatment values were calculated. Cox regression model and landmark method at end of induction and 6 months were used to evaluate the association between ferritin, CRP and distant metastasis-free survival (DMFS). Baseline ferritin levels were comparable in the two treatment groups (P=0.92). However, ferritin ratios were significantly higher in IFN-treated patients (N=96) compared with untreated patients (N=21) at end of induction (mean: 2.88 vs. 0.75; P=0.0003) and at 6 months (mean: 3.18 vs. 1.02; P=0.009). In the IFN arm, higher ferritin ratios at end of induction and at 6 months were not associated with improved outcome (respectively, P=0.66 and 0.86). Concerning CRP ratios, no differences between the treatment groups, neither an association with DMFS, were observed. Administration of IFN in melanoma patients induced increase in ferritin levels but not in CRP levels. Ferritin and CRP ratios have no prognostic value regarding DMFS.