Jun Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Huang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Xi Cao
School of Nursing, Sun Yat-sen University, Guangzhou, China
2 shared publications Hai Deng
Guangdong Provincial Key Laboratory of Clinical Pharmacology, Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080 Guangzhou, Guangdong, China
1 shared publication- Haiyue Gu
The School of Nursing Sun Yat‐sen University Guangzhou China
1 shared publication - Shuqian Qiao
The School of Nursing, Sun Yat-Sen University, Guangzhou, China
1 shared publication - Xu Liu
The Nethersole School of Nursing, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
1 shared publication - Xueru Yang
The School of Nursing, Sun Yat-Sen University, 510080 Guangzhou, Guangdong, China
1 shared publication
Latest Publications
- Open Access
- 23 July 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (7) , 36262
Screening for Atrial Fibrillation in Stroke Prevention: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
Background: Evidence is needed to determine the benefits and harms of screening for atrial fibrillation (AF) in stroke prevention. This meta-analysis aimed to evaluate the benefits and issues of AF screening among older adults. Methods: This systematic review and meta-analysis were conducted and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. We systematically searched several databases from inception through 28 March 2025, selecting randomized controlled trials (RCTs) comparing AF screening, including systematic and opportunistic screening, versus routine practice or no screening. Two reviewers independently extracted the data and appraised the risks of bias of the studies. Results: Thirteen articles covering 12 RCTs were included in the meta-analysis. For routine screening, systematic screening, rather than opportunistic screening, was more effective in detecting new AF cases (relative risk (RR), 2.07; 95% CI, 1.41 to 3.04; p = 0.0002). However, no difference was observed in the effectiveness of systematic and opportunistic screening in detecting AF (RR, 1.39; 95% CI, 0.59 to 3.30; p = 0.45). Compared with no screening, single-time-point screening did not improve the AF detection rate, whereas intermittent/continuous screening was associated with a greater likelihood of detecting AF (RR, 2.40; 95% CI, 1.59 to 3.64; p < 0.0001). There were no significant differences in the anticoagulation prescription rate between patients who underwent screening and routine care (RR, 1.16; 95% CI, 0.94 to 1.44; p = 0.16). Systematic screening was associated with a lower risk for the composite endpoint (combination of thrombosis-related events and mortality; RR, 0.96; 95% CI, 0.93 to 0.99; p = 0.02) but not for the individual endpoints. Compared with routine care, systematic screening did not increase the risk of major bleeding (RR, 0.88; 95% CI, 0.72 to 1.06; p = 0.18), whereas a positive screening result could promote anxiety. Conclusions: Systematic screening outperformed routine care but was comparable to opportunistic screening in detecting undiagnosed AF. Systematic screening was related to a reduction in the composite endpoints of stroke and all-cause mortality without increasing the risk of bleeding. PROSPERO Registration: This systematic review was prospectively registered in PROSPERO, registration number: CRD42024558614, https://www.crd.york.ac.uk/PROSPERO/view/CRD42024558614.
- 23 July 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (7) , 36262
Open AccessScreening for Atrial Fibrillation in Stroke Prevention: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
Background: Evidence is needed to determine the benefits and harms of screening for atrial fibrillation (AF) in stroke prevention. This meta-analysis aimed to evaluate the benefits and issues of AF screening among older adults. Methods: This systematic review and meta-analysis were conducted and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. We systematically searched several databases from inception through 28 March 2025, selecting randomized controlled trials (RCTs) comparing AF screening, including systematic and opportunistic screening, versus routine practice or no screening. Two reviewers independently extracted the data and appraised the risks of bias of the studies. Results: Thirteen articles covering 12 RCTs were included in the meta-analysis. For routine screening, systematic screening, rather than opportunistic screening, was more effective in detecting new AF cases (relative risk (RR), 2.07; 95% CI, 1.41 to 3.04; p = 0.0002). However, no difference was observed in the effectiveness of systematic and opportunistic screening in detecting AF (RR, 1.39; 95% CI, 0.59 to 3.30; p = 0.45). Compared with no screening, single-time-point screening did not improve the AF detection rate, whereas intermittent/continuous screening was associated with a greater likelihood of detecting AF (RR, 2.40; 95% CI, 1.59 to 3.64; p < 0.0001). There were no significant differences in the anticoagulation prescription rate between patients who underwent screening and routine care (RR, 1.16; 95% CI, 0.94 to 1.44; p = 0.16). Systematic screening was associated with a lower risk for the composite endpoint (combination of thrombosis-related events and mortality; RR, 0.96; 95% CI, 0.93 to 0.99; p = 0.02) but not for the individual endpoints. Compared with routine care, systematic screening did not increase the risk of major bleeding (RR, 0.88; 95% CI, 0.72 to 1.06; p = 0.18), whereas a positive screening result could promote anxiety. Conclusions: Systematic screening outperformed routine care but was comparable to opportunistic screening in detecting undiagnosed AF. Systematic screening was related to a reduction in the composite endpoints of stroke and all-cause mortality without increasing the risk of bleeding. PROSPERO Registration: This systematic review was prospectively registered in PROSPERO, registration number: CRD42024558614, https://www.crd.york.ac.uk/PROSPERO/view/CRD42024558614.
- Open Access
- 29 September 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Effectiveness of Single-lead ECG Devices for Detecting Atrial Fibrillation: An Overview of Systematic Reviews (Preprint)
BACKGROUND Atrial fibrillation (AF) carries increased risk for stroke, but much AF remains undiagnosed. Early detecting the undiagnosed AF via screening is suggested. Single-lead electrocardiogram (ECG) is the most widely used technology in AF detection. Several systematic reviews on the diagnostic accuracy of single-lead ECG devices for AF detection have been performed but yielded inconclusive results. OBJECTIVE To synthesize the available evidence on the effectiveness of single-lead ECG devices in detecting AF. METHODS Five English databases (Cochrane Database of Systematic Reviews, PubMed, Embase, Ovid, and Web of Science) and two Chinese databases (Wanfang and CNKI) were searched from the inception to July 31, 2021. Systematic reviews that examined the accuracy of tools based on single-lead ECG technology for detecting AF were included. A narrative data synthesis was performed. RESULTS Eight systematic reviews were finally included. Systematic reviews with meta-analysis showed that single-lead ECG based devices had good sensitivity and specificity (both ≥ 90%) in detecting AF. According to subgroup analysis, the sensitivities of tools used in populations with a history of AF were all greater than 90%. However, among handheld and thoracic placed single-lead ECG devices, large variations in their diagnostic performance were observed. CONCLUSIONS Single-lead ECG based devices have the potential for AF detection. While we were unable to determine the best option due to population heterogeneity and a lack of data on direct comparison between tools. Future studies are warranted to explore the suitable circumstance in which the effectiveness and cost-effectiveness these tools could be maximized for AF screening.
- 29 September 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEffectiveness of Single-lead ECG Devices for Detecting Atrial Fibrillation: An Overview of Systematic Reviews (Preprint)
BACKGROUND Atrial fibrillation (AF) carries increased risk for stroke, but much AF remains undiagnosed. Early detecting the undiagnosed AF via screening is suggested. Single-lead electrocardiogram (ECG) is the most widely used technology in AF detection. Several systematic reviews on the diagnostic accuracy of single-lead ECG devices for AF detection have been performed but yielded inconclusive results. OBJECTIVE To synthesize the available evidence on the effectiveness of single-lead ECG devices in detecting AF. METHODS Five English databases (Cochrane Database of Systematic Reviews, PubMed, Embase, Ovid, and Web of Science) and two Chinese databases (Wanfang and CNKI) were searched from the inception to July 31, 2021. Systematic reviews that examined the accuracy of tools based on single-lead ECG technology for detecting AF were included. A narrative data synthesis was performed. RESULTS Eight systematic reviews were finally included. Systematic reviews with meta-analysis showed that single-lead ECG based devices had good sensitivity and specificity (both ≥ 90%) in detecting AF. According to subgroup analysis, the sensitivities of tools used in populations with a history of AF were all greater than 90%. However, among handheld and thoracic placed single-lead ECG devices, large variations in their diagnostic performance were observed. CONCLUSIONS Single-lead ECG based devices have the potential for AF detection. While we were unable to determine the best option due to population heterogeneity and a lack of data on direct comparison between tools. Future studies are warranted to explore the suitable circumstance in which the effectiveness and cost-effectiveness these tools could be maximized for AF screening.