John V. Seeley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
John V. Seeley has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Stacy K. Seeley
Kettering University, Department of Chemistry & Biochemistry, Flint, MI 48504, USA
13 shared publicationsJames D. McCurry
5 shared publicationsElise K. Libby
Oakland University, Department of Chemistry , Rochester, MI 48309
2 shared publicationsElise M. Libby
2 shared publicationsFrederick J. Kramp
Oakland University, Department of Chemistry, Rochester, MI 48309, USA; Fax: 1 248 370‐2321
2 shared publicationsKristopher S. Sharpe
Oakland University, Department of Chemistry, Rochester, MI 48309, USA; Fax: 1 248 370‐2321
2 shared publications
Latest Publications
- 1 February 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1536, 6-15
The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography
- 1 February 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1536, 6-15
The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography
- 1 November 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1421, 114-122
Comprehensive two-dimensional gas chromatography with pattern modulation
- 1 November 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1421, 114-122
Comprehensive two-dimensional gas chromatography with pattern modulation
- 1 September 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1360, 258-263
Analysis of siloxanes in hydrocarbon mixtures using comprehensive two-dimensional gas chromatography
- 1 September 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1360, 258-263
Analysis of siloxanes in hydrocarbon mixtures using comprehensive two-dimensional gas chromatography
- 8 November 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (2) , 557-578
Multidimensional Gas Chromatography: Fundamental Advances and New Applications
- 8 November 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (2) , 557-578
Multidimensional Gas Chromatography: Fundamental Advances and New Applications
- 1 September 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1255, 24-37
Recent advances in flow-controlled multidimensional gas chromatography
- 1 September 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1255, 24-37
Recent advances in flow-controlled multidimensional gas chromatography
- 1 February 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1226, 103-109
Stationary phase selection and comprehensive two-dimensional gas chromatographic analysis of trace biodiesel in petroleum-based fuel
- 1 February 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1226, 103-109
Stationary phase selection and comprehensive two-dimensional gas chromatographic analysis of trace biodiesel in petroleum-based fuel
- 1 March 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (10) , 1650-1657
Solvation parameter model of comprehensive two-dimensional gas chromatography separations
- 1 March 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (10) , 1650-1657
Solvation parameter model of comprehensive two-dimensional gas chromatography separations
- Open Access
- 16 October 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (19) , 3337-3346
Comprehensive two‐dimensional gas chromatography analysis of high‐ethanol containing motor fuels
A comprehensive 2‐D GC (GC×GC) instrument equipped with a flow‐switching modulator was used to determine the concentration of ethanol and eight other alcohols in a retail pump sample of E85 fuel. E85 is a mixture of ethanol and gasoline where the ethanol concentration can range from 70 to 85 vol%. The increased peak capacity and selectivity generated by GC×GC analysis allowed the alcohols to be fully resolved from the gasoline hydrocarbons. GC×GC analysis was compared to the performance obtained with the standard analytical method for determining ethanol in fuel ethanol (ASTM D5501) and the standard method for determining oxygenate concentrations in gasoline (ASTM D4815). The GC×GC analysis required 14 min while the combined ASTM D5501 and ASTM D4815 analyses required more than 60 min. The ethanol concentration obtained by GC×GC was in excellent agreement with the value obtained by the D5501 method. Poorer agreement was observed between the GC×GC and D4815 concentrations for the other alcohols present in E85. In all cases, the differences could be attributed to deficiencies in the D4815 method that led to coelutions between the alcohols and gasoline hydrocarbons.
- 16 October 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (19) , 3337-3346
Open AccessComprehensive two‐dimensional gas chromatography analysis of high‐ethanol containing motor fuels
A comprehensive 2‐D GC (GC×GC) instrument equipped with a flow‐switching modulator was used to determine the concentration of ethanol and eight other alcohols in a retail pump sample of E85 fuel. E85 is a mixture of ethanol and gasoline where the ethanol concentration can range from 70 to 85 vol%. The increased peak capacity and selectivity generated by GC×GC analysis allowed the alcohols to be fully resolved from the gasoline hydrocarbons. GC×GC analysis was compared to the performance obtained with the standard analytical method for determining ethanol in fuel ethanol (ASTM D5501) and the standard method for determining oxygenate concentrations in gasoline (ASTM D4815). The GC×GC analysis required 14 min while the combined ASTM D5501 and ASTM D4815 analyses required more than 60 min. The ethanol concentration obtained by GC×GC was in excellent agreement with the value obtained by the D5501 method. Poorer agreement was observed between the GC×GC and D4815 concentrations for the other alcohols present in E85. In all cases, the differences could be attributed to deficiencies in the D4815 method that led to coelutions between the alcohols and gasoline hydrocarbons.
- Open Access
- 1 November 2007
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 45 (10) , 657-663
A Comprehensive Two-Dimensional Gas Chromatography Method for Analyzing Extractable Petroleum Hydrocarbons in Water and Soil
A flow-switching two-dimensional gas chromatography (GC×GC) apparatus has been constructed that can operate at temperatures as high as 340°C. This system is employed to analyze complex hydrocarbon mixtures such as diesel fuel, gas-oil, motor oil, and petroleum contaminated environmental samples. The GC×GC system generates two-dimensional chromatograms with minimal overlap between the aliphatic and aromatic regions. This allows these compound classes to be independently quantitated without prior fractionation. The GC×GC system is used to analyze extracts of spiked water samples, wastewater, and soil. The accuracy of the method is compared to that of the Massachusetts Extractable Petroleum Hydrocarbons (MA EPH) method. The GC×GC system generates a quantitative accuracy similar to the MA EPH method for the analysis of spiked water samples. The GC×GC method and the MA EPH method generate comparable levels of total hydrocarbons when wastewater is analyzed, but the GC×GC method detects a significantly higher aromatic content and lower aliphatic content. Both the GC×GC method and MA EPH method measure comparable levels of aromatics in the soil samples.
- 1 November 2007
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 45 (10) , 657-663
Open AccessA Comprehensive Two-Dimensional Gas Chromatography Method for Analyzing Extractable Petroleum Hydrocarbons in Water and Soil
A flow-switching two-dimensional gas chromatography (GC×GC) apparatus has been constructed that can operate at temperatures as high as 340°C. This system is employed to analyze complex hydrocarbon mixtures such as diesel fuel, gas-oil, motor oil, and petroleum contaminated environmental samples. The GC×GC system generates two-dimensional chromatograms with minimal overlap between the aliphatic and aromatic regions. This allows these compound classes to be independently quantitated without prior fractionation. The GC×GC system is used to analyze extracts of spiked water samples, wastewater, and soil. The accuracy of the method is compared to that of the Massachusetts Extractable Petroleum Hydrocarbons (MA EPH) method. The GC×GC system generates a quantitative accuracy similar to the MA EPH method for the analysis of spiked water samples. The GC×GC method and the MA EPH method generate comparable levels of total hydrocarbons when wastewater is analyzed, but the GC×GC method detects a significantly higher aromatic content and lower aliphatic content. Both the GC×GC method and MA EPH method measure comparable levels of aromatics in the soil samples.
- Open Access
- 1 November 2007
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 45 (10) , 650-656
Analysis of Biodiesel/Petroleum Diesel Blends with Comprehensive Two-Dimensional Gas Chromatography
Comprehensive two-dimensional gas chromatography (GC×GC) is used to analyze petroleum diesel, biodiesel, and biodiesel/petroleum diesel blends. The GC×GC instrument is assembled from a conventional gas chromatograph fitted with a simple, in-line fluidic modulator. A 5% phenyl polydimethylsiloxane primary column is coupled to a polyethylene glycol secondary column. This column combination generates chromatograms where the fatty acid methyl esters (FAMEs) found in biodiesel occupy a region that is also populated by numerous cyclic alkanes and monoaromatics found in petroleum. Fortunately, the intensities of the petroleum hydrocarbon peaks are far lower than the intensities of the FAME peaks, even for blends with low biodiesel content. This allows the FAMEs to be accurately quantitated by direct integration. The method is calibrated by analyzing standard mixtures of soybean biodiesel in petroleum diesel with concentrations ranging from 1 to 20% v/v. The resulting calibration curve displays excellent linearity. This curve is used to determine the concentration of a B20 biodiesel/petroleum diesel blend obtained from a local retailer. Excellent precision and accuracy are obtained.
- 1 November 2007
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 45 (10) , 650-656
Open AccessAnalysis of Biodiesel/Petroleum Diesel Blends with Comprehensive Two-Dimensional Gas Chromatography
Comprehensive two-dimensional gas chromatography (GC×GC) is used to analyze petroleum diesel, biodiesel, and biodiesel/petroleum diesel blends. The GC×GC instrument is assembled from a conventional gas chromatograph fitted with a simple, in-line fluidic modulator. A 5% phenyl polydimethylsiloxane primary column is coupled to a polyethylene glycol secondary column. This column combination generates chromatograms where the fatty acid methyl esters (FAMEs) found in biodiesel occupy a region that is also populated by numerous cyclic alkanes and monoaromatics found in petroleum. Fortunately, the intensities of the petroleum hydrocarbon peaks are far lower than the intensities of the FAME peaks, even for blends with low biodiesel content. This allows the FAMEs to be accurately quantitated by direct integration. The method is calibrated by analyzing standard mixtures of soybean biodiesel in petroleum diesel with concentrations ranging from 1 to 20% v/v. The resulting calibration curve displays excellent linearity. This curve is used to determine the concentration of a B20 biodiesel/petroleum diesel blend obtained from a local retailer. Excellent precision and accuracy are obtained.