PHPeng Huang

Peng Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peng Huang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Partial Impedance Decoupling Control Method for PMSG-Based Wind Farms Connected to a Weak Grid

    by Zixiao Lin, Luona Xu, Niancheng Zhou, Peng Huang, Chaoqing Zhang

    Under weak grid conditions, the coupling between the grid-connected converter and the grid impedance tends to bring in harmonic instability in the permanent-magnet synchronous generators (PMSGs)-based wind farm system. Although the symmetrical phase-locked loop (SPLL) can decouple the converter from the grid, it exerts an impact on the system stability. To address this issue, this paper proposes a partial impedance decoupling control method based on the SPLL. Based on a small-signal impedance model, the grid-GSC impedance decoupling mechanism of the SPLL and its adverse impact on system stability are analytically revealed. Furthermore, a partial impedance decoupling method is realized that incorporates adjustment coefficients and symmetric compensation to achieve a trade-off between damping enhancement and coupling mitigation, thus expanding the stable operating range of the PMSG-based wind farm system. Both simulation and experimental results demonstrate that the proposed strategy significantly improves system stability and maintains stable operation under grid conditions with a 10% reduction in short-circuit ratio (SCR).


  • Stability Boundary Evaluation Method for the Cascaded Bipolar DC Distribution System With CPLs Based on Impedance Analysis

    by Xiaolong Xu, Qianggang Wang, Jianquan Liao, Peng Huang, Tao Huang, Luona Xu, Niancheng Zhou

    At present, most existing methods for suppressing voltage oscillations induced by constant power loads (CPLs) in bipolar DC distribution systems (Bi-DCDSs) only focus on control frameworks, while the evaluation of the CPL power demand boundary defined by control parameters for ensuring system stability remains unexplored. To help tuning the control parameters, this paper proposes a boundary evaluation method to support control parameter tuning and thereby ensure the stability of Bi-DCDSs. The methods for suppressing voltage oscillations discussed in this paper include: the virtual impedance control (VIC) method based on the positive and negative port components, and the VIC method based on the DC symmetrical components. Firstly, the source impedance models and load admittance models of the Bi-DCDS controlled by the two VIC methods are established. Based on these established models, the input-output gain matrices of the Bi-DCDS are derived, providing foundation for stability analysis. Using the Generalized Nyquist Criterion, the stability of a Bi-DCDS with specified parameters can be assessed. By exploring the stability of the Bi-DCDS under different CPL power demands, the boundary can be identified. The case study demonstrates that, for a ±375 V system, the evaluation results obtained by the proposed method deviate from the simulation-identified boundary by less than 2 kW, verifying the effectiveness of the proposed approach.

  • Dynamic Models for DC Fault Analysis of Actively Commutated CSC-HVDC Under Different Grid Strengths

    by Sihao Fu, Luona Xu, Qianggang Wang, Yongjie Luo, Niancheng Zhou, Peng Huang, Yuanzheng Lyu, Yu Tang

    Actively commutated current source converter based high-voltage direct current transmission (CSC-HVDC) with state-of-the-art high power IGCTs is a promising candidate due to its merits such as fault ride-through capability and small footprint. The existing dc fault models of CSC either focus on 3-level CSC topology or neglect the transient process and commutation of the converter after fault, not suitable for accurate dc fault analysis of CSC-HVDC. Moreover, the elimination of ac-filters at the point of common coupling (PCC) will lead to severe PCC voltage distortion of weak-grid connected CSC-HVDC after fault. The interaction between the valve-groups caused by the voltage distortion and its influence on the fault characteristics is yet to be studied. In this article, two dc fault analysis models for CSC-HVDC connected to ac grid with different strengths are proposed. Based on quasi-steady state assumptions and substitution theorem, a simplified model by decoupling the valve-groups at the PCC and its adaptability under different grid strengths are proposed for analytical studies of dc fault. For weak-grid connected CSC-HVDC, a fault analysis model is further derived based on the quantitative analysis of the interaction between valve-groups. The proposed models are validated through PSCAD simulations and HIL experiments.


  • Impedance Coupling Suppression Control Method for Offshore Wind Farms Integrated With MMC-HVDC System

    by Peng Huang, Niancheng Zhou, Yongjie Luo, Xiuchao Duan, Qianggang Wang

    With the expansion of offshore wind farms (WFs), the impedance of WFs exhibits increased negative damping and stronger impedance coupling with the modular multilevel converter (MMC). These effects result in sharper resonance peaks in the impedance of WFs, exacerbating oscillation problems. Existing oscillation suppression methods to improve the damping of individual converters are limited in effectiveness for systems with deep interaction. To address this issue, this article reveals that the negative-sequence impedance of the MMC is a crucial factor in its interaction with WFs. Based on this insight, a control method is proposed to suppress impedance coupling by blocking interaction paths. This method enables more targeted and effective improvements in system stability, especially within strong interaction frequency bands. The effectiveness of the proposed control method is validated through comprehensive simulations and experiments.


  • Open Access

    Mechanism Analysis and Suppression Strategy of Continuous High-Frequency Oscillation in MMC-HVDC System

    by Hongbin Wang, Niancheng Zhou, Peng Huang, Xiuchao Duan, Ruiling Huang

    The continuous high-frequency oscillation phenomenon of the MMC-HVDC system occurs frequently in practical engineering. How to design an effective oscillation suppression strategy based on the essential mechanism of continuous oscillation has not been sufficiently supported by theory. For this reason, this paper firstly analyzes the high-frequency oscillation characteristics of the MMC-HVDC system. On this basis, considering the influence of the control system time delay, the MMC high-frequency impedance model is established based on harmonic linearization. Thirdly, the dynamic interaction between the control system and the harmonic disturbance is analyzed, and the continuous oscillation mechanism of the MMC-HVDC system is revealed. Finally, a high-frequency oscillation suppression strategy is proposed, consisting of adding a nonlinear low-pass filter to the MMC voltage feedforward link and reducing the risk of oscillation in the 0–2000 Hz frequency band. The simplified impedance model and high-frequency oscillation suppression strategy are verified in time simulation.


  • Artificial Neural Networks Modeling Technology for Substrate Integrated Suspended Line

    by Shuxia Yan, Nana Yang, Zhifeng Chen, Peng Huang, Weiguang Shi

    A new method for parameter modeling of self-packaged Substrate Integrated Suspended Line (SISL) devices based on artificial neural network is proposed. The method only uses the input and output signals of self-packaged SISL devices, and does not need to establish the internal structure information of the model. The cost of modeling is greatly reduced and the design cycle of microwave passive devices is shortened. In addition, an improved training method is proposed based on the neural network to learn the relationship between electromagnetic response and geometric parameters, so that the proposed model can efficiently and accurately match the characteristics of SISL devices. The model takes geometric parameters as variables. It can provide the exact and rapid prediction for the electromagnetic response of SISL devices. The validity and accuracy of the parameter modeling technique based on an artificial neural network are verified by a modeling example of a wideband Yagi antenna.