    The Diagnostic Accuracy of Transcranial Color-Coded Doppler Ultrasound Technique in Stratifying Intracranial Cerebral Artery Stenoses in Cerebrovascular Disease Patients: A Systematic Review and Meta-Analysis

    by Simon Takadiyi Gunda, Jerica Hiu-Yui Yip, Veronica Tsam-Kit Ng, Ziman Chen, Xinyang Han, Xiangyan Chen, Marco Yiu-Chung Pang, Michael Tin-Cheung Ying

    The early and accurate stratification of intracranial cerebral artery stenosis (ICAS) is critical to inform treatment management and enhance the prognostic outcomes in patients with cerebrovascular disease (CVD). Digital subtraction angiography (DSA) is an invasive and expensive procedure but is the gold standard for the diagnosis of ICAS. Over recent years, transcranial color-coded Doppler ultrasound (TCCD) has been suggested to be a useful imaging method for accurately diagnosing ICAS. However, the diagnostic accuracy of TCCD in stratifying ICASs among patients with CVD remains unclear. Therefore, this systematic review and meta-analysis aimed at evaluating the diagnostic accuracy of TCCD in the stratification of intracranial steno-occlusions among CVD patients. A total of six databases—Embase, CINAHL, Medline, PubMed, Google Scholar, and Web of Science (core collection)—were searched for studies that assessed the diagnostic accuracy of TCCD in stratifying ICASs. The meta-analysis was performed using Meta-DiSc 1.4. The Quality Assessment of Diagnostic Accuracy Studies tool version 2 (QUADAS-2) assessed the risk of bias. Eighteen studies met all of the eligibility criteria. TCCD exhibited a high pooled diagnostic accuracy in stratifying intracranial steno-occlusions in patients presenting with CVD when compared to DSA as a reference standard (sensitivity = 90%; specificity = 87%; AUC = 97%). Additionally, the ultrasound parameters peak systolic velocity (PSV) and mean flow velocity (MFV) yielded a comparable diagnostic accuracy of “AUC = 0.96”. In conclusion, TCCD could be a noble, safe, and accurate alternative imaging technique to DSA that can provide useful diagnostic information in stratifying intracranial steno-occlusions in patients presenting with CVD. TCCD should be considered in clinical cases where access to DSA is limited.


  • Open Access

    A Comparative Study of Transcranial Color-Coded Doppler (TCCD) and Transcranial Doppler (TCD) Ultrasonography Techniques in Assessing the Intracranial Cerebral Arteries Haemodynamics

    by Simon Takadiyi Gunda, Tsam Kit Veronica Ng, Tsz-Ying Liu, Ziman Chen, Xinyang Han, Xiangyan Chen, Marco Yiu-Chung Pang, Michael Tin-Cheung Ying

    Cerebrovascular disease (CVD) poses a major public health and socio-economic burden worldwide due to its high morbidity and mortality rates. Accurate assessment of cerebral arteries’ haemodynamic plays a crucial role in the diagnosis and treatment management of CVD. The study compared a non-imaging transcranial Doppler ultrasound (TCD) and transcranial color-coded Doppler ultrasound (with (cTCCD) and without (ncTCCD)) angle correction in quantifying middle cerebral arteries (MCAs) haemodynamic parameters. A cross-sectional study involving 50 healthy adults aged ≥ 18 years was conducted. The bilateral MCAs were insonated via three trans-temporal windows (TTWs—anterior, middle, and posterior) using TCD, cTCCD, and ncTCCD techniques. The MCA peak systolic velocity (PSV) and mean flow velocity (MFV) were recorded at proximal and distal imaging depths that could be visualised on TCCD with a detectable spectral waveform. A total of 152 measurements were recorded in 41 (82%) subjects with at least one-sided open TTW across the three techniques. The mean PSVs measured using TCD, ncTCCD, and cTCCD were 83 ± 18 cm/s, 81 ± 19 cm/s, and 93 ± 21 cm/s, respectively. There was no significant difference in PSV between TCD and ncTCCD (bias = 2 cm/s, p = 1.000), whereas cTCCD yielded a significantly higher PSV than TCD and ncTCCD (bias = −10 cm/s, p < 0.001; bias = −12 cm/s, p ≤ 0.001, respectively). The bias in MFV between TCD and ncTCCD techniques was (bias = −0.5 cm/s; p = 1.000), whereas cTCCD demonstrated a higher MFV compared to TCD and ncTCCD (bias = −8 cm/s, p < 0.001; bias = −8 cm/s, p ≤ 0.001, respectively). TCCD is a practically applicable imaging technique in assessing MCA blood flow velocities. cTCCD is more accurate and tends to give higher MCA blood flow velocities than non-imaging TCD and ncTCCD techniques. ncTCCD is comparable to non-imaging TCD and should be considered in clinical cases where using both TCD and TCCD measurements is needed.


  • Open Access

    Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography

    by Chun Wai Chan, Sze Chai Christy Chow, Man Hei Kwok, Ka Ching Tiffany Ngan, Tsun Hei Or, Simon Takadiyi Gunda, Michael Ying

    Purpose: Carotid vessel wall volume (VWV) measurement on three-dimensional ultrasonography (3DUS) outperforms conventional two-dimensional ultrasonography for carotid atherosclerosis evaluation. Although time-saving semi-automated algorithms have been introduced, their clinical availability remains limited due to a lack of validation, particularly an extensive reliability analysis. This study compared inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid VWV measurements on 3DUS.Methods: Thirty-one 3DUS volume datasets were prospectively acquired from 20 healthy subjects, aged >18 years, without previous stroke, transient ischemic attack, or cardiovascular disease. Five observers segmented all volume datasets both manually and semi-automatically. The process was repeated five times. Reliability was expressed by the intraclass correlation coefficient, supplemented by the coefficient of variation.Results: Carotid VWV measurements using the common carotid artery (CCA) were more reliable than those using the internal carotid artery (ICA) or external carotid artery (ECA) for both manual and semiautomated segmentation (manual segmentation, CCA: inter-observer, 0.935; intra-observer, 0.934 to 0.966; ICA: inter-observer, 0.784; intra-observer, 0.756 to 0.878; ECA: inter-observer, 0.732; intraobserver, 0.919 to 0.962; semi-automated segmentation, CCA: inter-observer, 0.986; intra-observer, 0.954 to 0.993; ICA: inter-observer, 0.977; intra-observer, 0.958 to 0.978; ECA: inter-observer, 0.966; intra-observer, 0.884 to 0.937). Total carotid VWV measurements by manual (inter-observer, 0.922; intra-observer, 0.927 to 0.961) and semi-automated segmentation (inter-observer, 0.987; intra-observer, 0.968 to 0.989) were highly reliable. Semi-automated segmentation showed higher reliability than manual segmentation for both individual and total carotid VWV measurements.Conclusion: 3DUS carotid VWV measurements of the CCA are more reliable than measurements of the ICA and ECA. Total carotid VWV measurements are highly reliable. Semi-automated segmentation has higher reliability than manual segmentation.


  • Open Access

    Diagnostic Efficacy of Advanced Ultrasonography Imaging Techniques in Infants with Biliary Atresia (BA): A Systematic Review and Meta-Analysis

    by Simon Takadiyi Gunda, Nonhlanhla Chambara, Xiangyan Fiona Chen, Marco Yiu Chung Pang, Michael Tin-Cheung Ying

    The early diagnosis of biliary atresia (BA) in cholestatic infants is critical to the success of the treatment. Intraoperative cholangiography (IOC), an invasive imaging technique, is the current strategy for the diagnosis of BA. Ultrasonography has advanced over recent years and emerging techniques such as shear wave elastography (SWE) have the potential to improve BA diagnosis. This review sought to evaluate the diagnostic efficacy of advanced ultrasonography techniques in the diagnosis of BA. Six databases (CINAHL, Medline, PubMed, Google Scholar, Web of Science (core collection), and Embase) were searched for studies assessing the diagnostic performance of advanced ultrasonography techniques in differentiating BA from non-BA causes of infantile cholestasis. The meta-analysis was performed using Meta-DiSc 1.4 and Comprehensive Meta-analysis v3 software. Quality Assessment of Diagnostic Accuracy Studies tool version 2 (QUADAS-2) assessed the risk of bias. Fifteen studies consisting of 2185 patients (BA = 1105; non-BA = 1080) met the inclusion criteria. SWE was the only advanced ultrasonography technique reported and had a good pooled diagnostic performance (sensitivity = 83%; specificity = 77%; AUC = 0.896). Liver stiffness indicators were significantly higher in BA compared to non-BA patients (p < 0.000). SWE could be a useful tool in differentiating BA from non-BA causes of infantile cholestasis. Future studies to assess the utility of other advanced ultrasonography techniques are recommended.