JRJulius Reitemeier

Julius Reitemeier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Julius Reitemeier has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enzyme Dynamics in Attoliter-Volume Electrochemical Zero-Mode Waveguides with On-Demand In-Situ Hydrogen Peroxide Delivery and Consumption

    by Jarek Metro, Julius Reitemeier, Paul W. Bohn

    Physiological systems are not at equilibrium and undergo time-dependent fluctuations, making it challenging to relate in vitro studies to in vivo biomolecular behavior. To bridge this gap, enzyme dynamics can be studied in the presence of controlled perturbations that recapitulate the intracellular environment. Here, we report an approach to the study of reactive oxygen species (ROS) based on the in situ manipulation of hydrogen peroxide (H 2 O 2 ) levels in functionalized nanopore-based electrochemical zero-mode waveguide (EZMW) arrays, with each nanopore presenting small numbers of immobilized horseradish peroxidase (HRP) enzyme molecules. H 2 O 2 is generated or consumed within the attoliter volume of the EZMW nanopores by poising an embedded ring electrode to suitable potentials, and the resulting effect on apparent turnover of HRP under non-equilibrium conditions is monitored using the enzymatically accelerated conversion of the non-fluorescent probe Amplex Red to fluorescent resorufin. A Nafion membrane is placed on the top surface of the EZMW array, providing a cation permselective barrier to transport in, or out, of the EZMW nanopores, thereby improving the sensitivity of the experiment by sequestering enzymatically generated resorufin in the attoliter volume of the EZMW nanopores. By fabricating arrays presenting 441 individual reaction volumes in parallel, distinct changes in population dynamics in the presence of in situ H 2 O 2 generation or consumption are characterized with respect to temporal evolution and magnitude of the H 2 O 2 aliquot delivered. This approach presents a promising avenue for studying biomolecular reactions in spatiotemporally controlled chemical environments that can mimic the non-equilibrium conditions encountered in vivo.


  • Open Access

    Monitoring Populations of Single Extracellular Vesicles from Pseudomonas aeruginosa Using Large Parallel Arrays of Zero-Mode Waveguides

    by Jarek Metro, Abigail A. Weaver, Julius Reitemeier, Charlie Desnoyers, Paul W. Bohn

    Extracellular vesicles (EV) have emerged as key factors for intercellular communication, disease biomarkers, and vaccines, but EV populations generally exhibit broad heterogeneity, making single-vesicle measurements critical in order to understand the roles played by EVs and the pathways they utilize. To circumvent the exhaustive isolation and concentration protocols and/or long incubation periods required by common single-vesicle characterization methods, we have developed a method for the in situ study of single EVs from crude Pseudomonas aeruginosa culture in real-time with minimal sample preparation using nanopore-based zero-mode waveguides (ZMW). The dimensions of the ZMW allow only a single EV to occupy the nanopore volume, making it possible to monitor large arrays of single EVs one-at-a-time in parallel. Furthermore, the attoliter-volume ZMW nanopores restrict the much larger P. aeruginosa cells from entering the observation volume, eliminating the need to isolate EVs from their parent cells. Lipophilic fluorophores are used to selectively tag the EV membrane, thereby restricting optical observations to single EVs captured one-at-a-time in individual ZMW nanopores. By fashioning the ZMWs into 21 × 21 arrays, 441 individual observation volumes can be observed in parallel, revealing the heterogeneity of single EV responses, which is usually masked by ensemble averaging when examining hundreds of events at once without spatial segregation. The minimal sample preparation and ability to monitor the sample in situ enables real-time analysis of changes in the bacterial culture environment, since detection of EVs is governed solely by diffusion of the particle into the ZMW optical volume. The work described here presents an approach for studying EV heterogeneity in crude bacterial culture and makes it possible to observe shifts in the vesicle population in response to culture perturbations in real-time.


  • Open Access

    Nafion coated nanopore electrode for improving electrochemical aptamer-based biosensing

    by Grayson F. Huldin, Junming Huang, Julius Reitemeier, Kaiyu X. Fu

    Nafion blocks the aptamer's active sites from planar gold, while the aptamer retains its redox activity from nanoporous gold.


  • Hybrid Printing of Fully Integrated Microfluidic Devices for Biosensing

    by Yipu Du, Julius Reitemeier, Qiang Jiang, Omarsany Bappy, Paul W. Bohn, Yanliang Zhang

    The advent of 3D printing has facilitated the rapid fabrication of microfluidic devices that are accessible and cost‐effective. However, it remains a challenge to fabricate sophisticated microfluidic devices with integrated structural and functional components due to limited material options of existing printing methods and their stringent requirement on feedstock material properties. Here, a multi‐materials multi‐scale hybrid printing method that enables seamless integration of a broad range of structural and functional materials into complex devices is reported. A fully printed and assembly‐free microfluidic biosensor with embedded fluidic channels and functionalized electrodes at sub‐100 µm spatial resolution for the amperometric sensing of lactate in sweat is demonstrated. The sensors present a sensitive response with a limit of detection of 442 nm and a linear dynamic range of 1–10 mm, which are performance characteristics relevant to physiological levels of lactate in sweat. The versatile hybrid printing method offers a new pathway toward facile fabrication of next‐generation integrated devices for broad applications in point‐of‐care health monitoring and sensing.


  • Hydrophobic Gating and Spatial Confinement in Hierarchically Organized Block Copolymer-Nanopore Electrode Arrays for Electrochemical Biosensing of 4-Ethyl Phenol

    by Julius Reitemeier, Seol Baek, Paul W. Bohn

    Hydrophobic gating in biological transport proteins is regulated by stimulus-specific switching between filled and empty nanocavities, endowing them with selective mass transport capabilities. Inspired by these, solid-state nanochannels have been integrated into functional materials for a broad range of applications, such as energy conversion, filtration, and nanoelectronics, and here we extend these to electrochemical biosensors coupled to mass transport control elements. Specifically, we report hierarchically organized structures with block copolymers on tyrosinase-modified two-electrode nanopore electrode arrays (BCP@NEAs) as stimulus-controlled electrochemical biosensors for alkylphenols. A polystyrene-b-poly(4-vinyl)pyridine (PS-b-P4VP) membrane placed atop the NEA endows the system with potential-responsive gating properties, where water transport is spatially and temporarily gated through hydrophobic P4VP nanochannels by the application of appropriate potentials. The reversibility of hydrophobic voltage-gating makes it possible to capture and confine analyte species in the attoliter-volume vestibule of cylindrical nanopore electrodes, enabling redox cycling and yielding enhanced currents with amplification factors >100× when operated in a generator-collector mode. The enzyme-coupled sensing capabilities are demonstrated using nonelectroactive 4-ethyl phenol, exploiting the tyrosinase-catalyzed turnover into reversibly redox-active quinones, then using the quinone-catechol redox reaction to achieve ultrasensitive cycling currents in confined BCP@NEA sensors giving a limit-of-detection of ∼120 nM. The mass transport controlled sensing platform described here is relevant to the development of enzyme-coupled multiplex biosensors for sensitive and selective detection of biomarkers and metabolites in next-generation point-of-care devices.


  • Multifunctional nanopore electrode array method for characterizing and manipulating single entities in attoliter-volume enclosures

    by Seol Baek, Allison R. Cutri, Donghoon Han, Seung-Ryong Kwon, Julius Reitemeier, Vignesh Sundaresan, Paul W. Bohn

    Structurally regular nanopore arrays fabricated to contain independently controllable annular electrodes represent a new kind of architecture capable of electrochemically addressing small collections of matter—down to the single entity (molecule, particle, and biological cell) level. Furthermore, these nanopore electrode arrays (NEAs) can also be interrogated optically to achieve single entity spectroelectrochemistry. Larger entities such as nanoparticles and single bacterial cells are investigated by dark-field scattering and potential-controlled single-cell luminescence experiments, respectively, while NEA-confined molecules are probed by single molecule luminescence. By carrying out these experiments in arrays of identically constructed nanopores, massively parallel collections of single entities can be investigated simultaneously. The multilayer metal–insulator design of the NEAs enables highly efficient redox cycling experiments with large increases in analytical sensitivity for chemical sensing applications. NEAs may also be augmented with an additional orthogonally designed nanopore layer, such as a structured block copolymer, to achieve hierarchically organized multilayer structures with multiple stimulus-responsive transport control mechanisms. Finally, NEAs constructed with a transparent bottom layer permit optical access to the interior of the nanopore, which can result in the cutoff of far-field mode propagation, effectively trapping radiation in an ultrasmall volume inside the nanopore. The bottom metal layer may be used as both a working electrode and an optical cladding layer, thus, producing bifunctional electrochemical zero-mode waveguide architectures capable of carrying out spectroelectrochemical investigations down to the single molecule level.