Noboru Tanigawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Noboru Tanigawa has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Miyuki Nakatani
Department of Radiology, Kansai Medical University, Osaka, Japan
3 shared publications - Shuji Kariya
Department of Radiology, Kansai Medical University, Osaka, Japan
3 shared publications - Atsushi Komemushi
Department of Radiology, Kansai Medical University, Osaka, Japan
2 shared publications - Hideki Takegawa
Kansai Medical University
2 shared publications Midori Yui
Department of Radiology, Kansai Medical University Graduate School of Medicine, Osaka, Japan
2 shared publications- Satoaki Nakamura
Division of Radiation Oncology, Kansai Medical University , 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010
2 shared publications
Latest Publications
- Open Access
Advances in Transarterial Radionuclide Therapy for Hepatocellular Carcinoma and Other Liver Tumors: From Yttrium-90 Radioembolization to Emerging Lipiodol-Based Theranostic Approaches
Hepatocellular carcinoma (HCC) remains a leading cause of cancer-related mortality, and internal radionuclide therapy is an important locoregional option for unresectable disease. This review summarizes the current landscape of transarterial radionuclide therapy for HCC and, as a translational perspective, considers how the carrier, radionuclide, and dosimetry concepts established in HCC may extend to secondary liver tumors (liver metastases). It begins with established transarterial radioembolization (TARE/selective internal radiation therapy, SIRT) using yttrium-90 (90Y) microspheres and the shift toward personalized dosimetry and combination with systemic and immune-based therapies. It then examines alternative radionuclides and carrier systems—including holmium-166 (166Ho) microspheres, iodine-131 (131I) lipiodol, rhenium-188 (188Re) lipiodol, and lutetium-177 emulsified in lipiodol (177Lu-lipiodol)—from the standpoint of their physical properties, radiochemistry, theranostic potential, and preclinical and clinical evidence. Particular attention is given to 177Lu-based approaches, including their favorable beta energy, the concurrent imageable gamma emission that enables single-photon emission computed tomography (SPECT)-based dosimetry, and the potential to address post-embolization hypoxia-related radioresistance, while noting that the clinical evidence for 177Lu-lipiodol remains preclinical. The application of these platforms to colorectal and neuroendocrine liver metastases is then outlined. Finally, regulatory, radiation safety, and waste management considerations and the principal challenges to clinical translation are discussed.
Open AccessAdvances in Transarterial Radionuclide Therapy for Hepatocellular Carcinoma and Other Liver Tumors: From Yttrium-90 Radioembolization to Emerging Lipiodol-Based Theranostic Approaches
Hepatocellular carcinoma (HCC) remains a leading cause of cancer-related mortality, and internal radionuclide therapy is an important locoregional option for unresectable disease. This review summarizes the current landscape of transarterial radionuclide therapy for HCC and, as a translational perspective, considers how the carrier, radionuclide, and dosimetry concepts established in HCC may extend to secondary liver tumors (liver metastases). It begins with established transarterial radioembolization (TARE/selective internal radiation therapy, SIRT) using yttrium-90 (90Y) microspheres and the shift toward personalized dosimetry and combination with systemic and immune-based therapies. It then examines alternative radionuclides and carrier systems—including holmium-166 (166Ho) microspheres, iodine-131 (131I) lipiodol, rhenium-188 (188Re) lipiodol, and lutetium-177 emulsified in lipiodol (177Lu-lipiodol)—from the standpoint of their physical properties, radiochemistry, theranostic potential, and preclinical and clinical evidence. Particular attention is given to 177Lu-based approaches, including their favorable beta energy, the concurrent imageable gamma emission that enables single-photon emission computed tomography (SPECT)-based dosimetry, and the potential to address post-embolization hypoxia-related radioresistance, while noting that the clinical evidence for 177Lu-lipiodol remains preclinical. The application of these platforms to colorectal and neuroendocrine liver metastases is then outlined. Finally, regulatory, radiation safety, and waste management considerations and the principal challenges to clinical translation are discussed.
- Open Access
- 27 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1637
Effect of Irreversible Compression on the Pulmonary Nodule Detection Rate in Chest Radiographs Using AI Software
Objectives: Whereas irreversible compression of Digital Imaging and Communications in Medicine (DICOM) files can reduce data size, research on its impact on diagnostic ability when using artificial intelligence (AI) software is limited. The objective was to determine the effect that irreversible compression has on diagnostic ability when using AI software. In addition, the effect of nodal properties on computed tomography (CT) on detection rates was examined. Methods: A total of 335 patients with pulmonary nodules were included. Chest radiographs were subjected to irreversible compression at 10:1 and 50:1 ratios. The associations between the detection rate of the AI software and factors such as location on CT, morphology, and diameter, were determined. Results: The number of positive cases identified with the AI imaging software was as follows: 188 cases (56.1%) with no compression, 184 cases (54.9%) with 10:1 compression, and 175 cases (52.2%) with 50:1 compression. There was a significant difference between the uncompressed images and the 50:1 compressed images, as well as between the 10:1 compressed images and the 50:1 compressed images (all p < 0.05). With all compression ratios, there were significant differences in the associations between the AI software’s nodule detection rate and the target nodule’s maximum diameter, minimum diameter, morphology, and overlap with multiple organs on CT (all p < 0.0001). Conclusions: The detection rate by the AI software of lung tumors on chest radiographs showed no significant difference when images were subjected to 10:1 irreversible compression; however, there was a significant decrease when subjected to 50:1 irreversible compression.
- 27 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1637
Open AccessEffect of Irreversible Compression on the Pulmonary Nodule Detection Rate in Chest Radiographs Using AI Software
Objectives: Whereas irreversible compression of Digital Imaging and Communications in Medicine (DICOM) files can reduce data size, research on its impact on diagnostic ability when using artificial intelligence (AI) software is limited. The objective was to determine the effect that irreversible compression has on diagnostic ability when using AI software. In addition, the effect of nodal properties on computed tomography (CT) on detection rates was examined. Methods: A total of 335 patients with pulmonary nodules were included. Chest radiographs were subjected to irreversible compression at 10:1 and 50:1 ratios. The associations between the detection rate of the AI software and factors such as location on CT, morphology, and diameter, were determined. Results: The number of positive cases identified with the AI imaging software was as follows: 188 cases (56.1%) with no compression, 184 cases (54.9%) with 10:1 compression, and 175 cases (52.2%) with 50:1 compression. There was a significant difference between the uncompressed images and the 50:1 compressed images, as well as between the 10:1 compressed images and the 50:1 compressed images (all p < 0.05). With all compression ratios, there were significant differences in the associations between the AI software’s nodule detection rate and the target nodule’s maximum diameter, minimum diameter, morphology, and overlap with multiple organs on CT (all p < 0.0001). Conclusions: The detection rate by the AI software of lung tumors on chest radiographs showed no significant difference when images were subjected to 10:1 irreversible compression; however, there was a significant decrease when subjected to 50:1 irreversible compression.
- 22 August 2025
- Published by Springer Nature in Journal of Gastroenterology
- Vol. 60 (12) , 1471-1480
Evidence for imaging-based diagnosis of liver metastases from colorectal cancer
Metastatic liver tumors are more common than primary liver cancers and are the most common liver malignancies. Performing B-mode ultrasonography and contrast-enhanced computed tomography is generally necessary for the diagnosis of liver metastases. However, various modalities, including dynamic contrast-enhanced computed tomography and magnetic resonance imaging using liver-specific contrast agents such as gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid, fluorodeoxyglucose positron emission tomography, and a combination of positron emission tomography and computed tomography, are also used. Improvements in imaging technology have made the detection of small liver masses possible, and liver metastases are being diagnosed more frequently, both before and after primary tumor treatment. The diagnosis of liver metastasis is related to treatment, and the benefits of liver resection depend on the primary tumor. For colorectal cancer, resection of liver metastases is beneficial. However, resection is not recommended for pancreatic or biliary tract cancers.
- 22 August 2025
- Published by Springer Nature in Journal of Gastroenterology
- Vol. 60 (12) , 1471-1480
Evidence for imaging-based diagnosis of liver metastases from colorectal cancer
Metastatic liver tumors are more common than primary liver cancers and are the most common liver malignancies. Performing B-mode ultrasonography and contrast-enhanced computed tomography is generally necessary for the diagnosis of liver metastases. However, various modalities, including dynamic contrast-enhanced computed tomography and magnetic resonance imaging using liver-specific contrast agents such as gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid, fluorodeoxyglucose positron emission tomography, and a combination of positron emission tomography and computed tomography, are also used. Improvements in imaging technology have made the detection of small liver masses possible, and liver metastases are being diagnosed more frequently, both before and after primary tumor treatment. The diagnosis of liver metastasis is related to treatment, and the benefits of liver resection depend on the primary tumor. For colorectal cancer, resection of liver metastases is beneficial. However, resection is not recommended for pancreatic or biliary tract cancers.
- Open Access
- 30 April 2025
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 14 (2) , 71-76
Evaluation of simultaneous tandem drainage of intra-abdominal abscesses caused by gastrointestinal anastomotic failure
Yutaka Ueno, Shuji Kariya, Miyuki Nakatani, Yasuyuki Ono, Takuji Maruyama, Yuki Tanaka, Kanji Sugiura, and Noboru Tanigawa. Int J Gastrointest Interv 2025;14:71-6. https://doi.org/10.18528/ijgii240080
- 30 April 2025
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 14 (2) , 71-76
Open AccessEvaluation of simultaneous tandem drainage of intra-abdominal abscesses caused by gastrointestinal anastomotic failure
Yutaka Ueno, Shuji Kariya, Miyuki Nakatani, Yasuyuki Ono, Takuji Maruyama, Yuki Tanaka, Kanji Sugiura, and Noboru Tanigawa. Int J Gastrointest Interv 2025;14:71-6. https://doi.org/10.18528/ijgii240080
- 29 March 2023
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 41 (8) , 900-908
Deep learning-based detection of patients with bone metastasis from Japanese radiology reports
Purpose Deep learning (DL) is a state-of-the-art technique for developing artificial intelligence in various domains and it improves the performance of natural language processing (NLP). Therefore, we aimed to develop a DL-based NLP model that classifies the status of bone metastasis (BM) in radiology reports to detect patients with BM. Materials and Methods The DL-based NLP model was developed by training long short-term memory using 1,749 free-text radiology reports written in Japanese. We adopted five-fold cross-validation and used 200 reports for testing the five models. The accuracy, sensitivity, specificity, precision, and area under the receiver operating characteristics curve (AUROC) were used for the model evaluation. Results The developed model demonstrated classification performance with mean ± standard deviation of 0.912 ± 0.012, 0.924 ± 0.029, 0.901 ± 0.014, 0.898 ± 0.012, and 0.968 ± 0.004 for accuracy, sensitivity, specificity, precision, and AUROC, respectively. Conclusion The proposed DL-based NLP model may help in the early and efficient detection of patients with BM.
- 29 March 2023
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 41 (8) , 900-908
Deep learning-based detection of patients with bone metastasis from Japanese radiology reports
Purpose Deep learning (DL) is a state-of-the-art technique for developing artificial intelligence in various domains and it improves the performance of natural language processing (NLP). Therefore, we aimed to develop a DL-based NLP model that classifies the status of bone metastasis (BM) in radiology reports to detect patients with BM. Materials and Methods The DL-based NLP model was developed by training long short-term memory using 1,749 free-text radiology reports written in Japanese. We adopted five-fold cross-validation and used 200 reports for testing the five models. The accuracy, sensitivity, specificity, precision, and area under the receiver operating characteristics curve (AUROC) were used for the model evaluation. Results The developed model demonstrated classification performance with mean ± standard deviation of 0.912 ± 0.012, 0.924 ± 0.029, 0.901 ± 0.014, 0.898 ± 0.012, and 0.968 ± 0.004 for accuracy, sensitivity, specificity, precision, and AUROC, respectively. Conclusion The proposed DL-based NLP model may help in the early and efficient detection of patients with BM.
- 29 March 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (10) , 1867-1874
Artificial intelligence-aided lytic spinal bone metastasis classification on CT scans
Purpose Spinal bone metastases directly affect quality of life, and patients with lytic-dominant lesions are at high risk for neurological symptoms and fractures. To detect and classify lytic spinal bone metastasis using routine computed tomography (CT) scans, we developed a deep learning (DL)-based computer-aided detection (CAD) system. Methods We retrospectively analyzed 2125 diagnostic and radiotherapeutic CT images of 79 patients. Images annotated as tumor (positive) or not (negative) were randomized into training (1782 images) and test (343 images) datasets. YOLOv5m architecture was used to detect vertebra on whole CT scans. InceptionV3 architecture with the transfer-learning technique was used to classify the presence/absence of lytic lesions on CT images showing the presence of vertebra. The DL models were evaluated via fivefold cross-validation. For vertebra detection, bounding box accuracy was estimated using intersection over union (IoU). We evaluated the area under the curve (AUC) of a receiver operating characteristic curve to classify lesions. Moreover, we determined the accuracy, precision, recall, and F1 score. We used the gradient-weighted class activation mapping (Grad-CAM) technique for visual interpretation. Results The computation time was 0.44 s per image. The average IoU value of the predicted vertebra was 0.923 ± 0.052 (0.684–1.000) for test datasets. In the binary classification task, the accuracy, precision, recall, F1-score, and AUC value for test datasets were 0.872, 0.948, 0.741, 0.832, and 0.941, respectively. Heat maps constructed using the Grad-CAM technique were consistent with the location of lytic lesions. Conclusion Our artificial intelligence-aided CAD system using two DL models could rapidly identify vertebra bone from whole CT images and detect lytic spinal bone metastasis, although further evaluation of diagnostic accuracy is required with a larger sample size.
- 29 March 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (10) , 1867-1874
Artificial intelligence-aided lytic spinal bone metastasis classification on CT scans
Purpose Spinal bone metastases directly affect quality of life, and patients with lytic-dominant lesions are at high risk for neurological symptoms and fractures. To detect and classify lytic spinal bone metastasis using routine computed tomography (CT) scans, we developed a deep learning (DL)-based computer-aided detection (CAD) system. Methods We retrospectively analyzed 2125 diagnostic and radiotherapeutic CT images of 79 patients. Images annotated as tumor (positive) or not (negative) were randomized into training (1782 images) and test (343 images) datasets. YOLOv5m architecture was used to detect vertebra on whole CT scans. InceptionV3 architecture with the transfer-learning technique was used to classify the presence/absence of lytic lesions on CT images showing the presence of vertebra. The DL models were evaluated via fivefold cross-validation. For vertebra detection, bounding box accuracy was estimated using intersection over union (IoU). We evaluated the area under the curve (AUC) of a receiver operating characteristic curve to classify lesions. Moreover, we determined the accuracy, precision, recall, and F1 score. We used the gradient-weighted class activation mapping (Grad-CAM) technique for visual interpretation. Results The computation time was 0.44 s per image. The average IoU value of the predicted vertebra was 0.923 ± 0.052 (0.684–1.000) for test datasets. In the binary classification task, the accuracy, precision, recall, F1-score, and AUC value for test datasets were 0.872, 0.948, 0.741, 0.832, and 0.941, respectively. Heat maps constructed using the Grad-CAM technique were consistent with the location of lytic lesions. Conclusion Our artificial intelligence-aided CAD system using two DL models could rapidly identify vertebra bone from whole CT images and detect lytic spinal bone metastasis, although further evaluation of diagnostic accuracy is required with a larger sample size.
- Open Access
- 31 October 2022
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 11 (4) , 186-191
The role of lymphatic interventional radiology for postoperative lymphorrhea
- 31 October 2022
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 11 (4) , 186-191
Open AccessThe role of lymphatic interventional radiology for postoperative lymphorrhea
- Open Access
- 1 March 2014
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 25 (3) , S57
Renal volume reduction by transcatheter renal artery embolization with N-butyl cyanoacrylate for symptomatic polycystic kidney disease
- 1 March 2014
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 25 (3) , S57
Open AccessRenal volume reduction by transcatheter renal artery embolization with N-butyl cyanoacrylate for symptomatic polycystic kidney disease
- Open Access
- 12 February 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (S2) , 157-160
Posterior Reversible Encephalopathy Syndrome Occurring After Uterine Artery Embolization for Uterine Myoma
This case report describes posterior reversible encephalopathy syndrome (PRES) occurring after uterine artery embolization (UAE) for uterine myoma. This is the first report of PRES occurring after uterine vascular radiologic intervention. The mechanism by which UAE induced PRES is unclear.
- 12 February 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (S2) , 157-160
Open AccessPosterior Reversible Encephalopathy Syndrome Occurring After Uterine Artery Embolization for Uterine Myoma
This case report describes posterior reversible encephalopathy syndrome (PRES) occurring after uterine artery embolization (UAE) for uterine myoma. This is the first report of PRES occurring after uterine vascular radiologic intervention. The mechanism by which UAE induced PRES is unclear.
- 1 May 1993
- Published by SAGE Publications in Acta Radiologica
- Vol. 34 (3) , 263-265
Treatment of Tuberculous Bronchial Stenosis with Expandable Metallic Stents
Gianturco expandable metallic stents were placed in 5 patients with dyspnea on exercise due to tuberculous bronchial stenosis. The stents were placed after dilatation with a 10-mm diameter high pressure balloon catheter. In all 5 patients, obstructive changes disappeared following the procedure, and dyspnea on exercise improved markedly. No complications related to the procedure were encountered. At follow-up during a period of up to 38 months, 2 patients showed bronchial restenosis at 11 and 17 months, respectively, after stent placement. Restenosis by granulomatous tissue was successfully treated by laser ablation. One patient showed slight one-day hemoptysis 26 months after stent placement.
- 1 May 1993
- Published by SAGE Publications in Acta Radiologica
- Vol. 34 (3) , 263-265
Treatment of Tuberculous Bronchial Stenosis with Expandable Metallic Stents
Gianturco expandable metallic stents were placed in 5 patients with dyspnea on exercise due to tuberculous bronchial stenosis. The stents were placed after dilatation with a 10-mm diameter high pressure balloon catheter. In all 5 patients, obstructive changes disappeared following the procedure, and dyspnea on exercise improved markedly. No complications related to the procedure were encountered. At follow-up during a period of up to 38 months, 2 patients showed bronchial restenosis at 11 and 17 months, respectively, after stent placement. Restenosis by granulomatous tissue was successfully treated by laser ablation. One patient showed slight one-day hemoptysis 26 months after stent placement.