Xu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xu Wang has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Yi Zhou
University of Science and Technology of China
8 shared publications I. Giomataris
6 shared publications- Jianbei Liu
University of Science and Technology of China
6 shared publications M. van Stenis
6 shared publications- Michelle Gallinaro
Laboratório de Instrumentação e Física Experimental de Partículas
6 shared publications P. Legou
6 shared publications
Latest Publications
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03015
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03015
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.
- Open Access
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Open AccessPhotocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- Open Access
- 1 August 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (08) , P08010
A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
- 1 August 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (08) , P08010
Open AccessA novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07031
The micro-resistive groove detector: a new compact single amplification-stage MPGD
In this paper, we introduce a novel single amplification-stage Micro-Pattern Gaseous Detector (MPGD) that incorporates a Diamond-Like Carbon (DLC)-based resistive electrode at the bottom of micro-groove structures, the micro-Resistive Groove (μRGroove) detector. The μRGroove shares a similar compact stack geometry with the micro-Resistive WELL (μRWELL) detector, but it distinguishes itself by employing a groove structure for charge amplification instead of a well. The top metal layer of the grooves naturally forms an array of strips. By incorporating additional 1-dimensional (1D) readout strips beneath the DLC electrode, a 2-dimensional (2D) strip-readout scheme can be easily implemented. Two prototypes of the μRGroove (10 cm× 10 cm) were manufactured in 2022 at CERN, and their performance was evaluated through X-ray and beam tests. The results indicate a gas gain > 104, an energy resolution of ~ 25%, and negligible charging-up effects for 8 keV Cu X-rays. Additionally, the detection efficiency was found to be ~ 95%, with a position resolution of ∼ 75 μm for 150-GeV/c muons. The μRGroove boasts a compact design and robustness against discharges. Furthermore, compared to the μRWELL, it offers cost savings in detector fabrication and yields significantly higher signal amplitude (approximately double) at the same gas gain. These attributes position the μRGroove as a promising candidate for large-area and low-material-budget tracking applications.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07031
The micro-resistive groove detector: a new compact single amplification-stage MPGD
In this paper, we introduce a novel single amplification-stage Micro-Pattern Gaseous Detector (MPGD) that incorporates a Diamond-Like Carbon (DLC)-based resistive electrode at the bottom of micro-groove structures, the micro-Resistive Groove (μRGroove) detector. The μRGroove shares a similar compact stack geometry with the micro-Resistive WELL (μRWELL) detector, but it distinguishes itself by employing a groove structure for charge amplification instead of a well. The top metal layer of the grooves naturally forms an array of strips. By incorporating additional 1-dimensional (1D) readout strips beneath the DLC electrode, a 2-dimensional (2D) strip-readout scheme can be easily implemented. Two prototypes of the μRGroove (10 cm× 10 cm) were manufactured in 2022 at CERN, and their performance was evaluated through X-ray and beam tests. The results indicate a gas gain > 104, an energy resolution of ~ 25%, and negligible charging-up effects for 8 keV Cu X-rays. Additionally, the detection efficiency was found to be ~ 95%, with a position resolution of ∼ 75 μm for 150-GeV/c muons. The μRGroove boasts a compact design and robustness against discharges. Furthermore, compared to the μRWELL, it offers cost savings in detector fabrication and yields significantly higher signal amplitude (approximately double) at the same gas gain. These attributes position the μRGroove as a promising candidate for large-area and low-material-budget tracking applications.
- Open Access
- 1 November 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1046
Sub-25 ps timing measurements with 10 × 10 cm PICOSEC Micromegas detectors- 1 November 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1046
Open AccessSub-25 ps timing measurements with 10 × 10 cm PICOSEC Micromegas detectors