Sombir Kundu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sombir Kundu has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Ashutosh K. Giri
Government Engineering College Bharuch
6 shared publications Ashutosh K. Giri
5 shared publications- Sunil Kadiyan
Ganga Institute of Technology and Management
5 shared publications - Madhusudan Singh
Department of Electrical Engineering, Delhi Technological University, New Delhi, India
4 shared publications Madhusudan Singh
3 shared publications- Sukhbir Singh
Delhi Technological University
3 shared publications
Latest Publications
- 17 November 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A robust AVF-RIBZAF control strategy for harmonic mitigation and dynamic performance improvement in Grid-Connected PV systems
- 17 November 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A robust AVF-RIBZAF control strategy for harmonic mitigation and dynamic performance improvement in Grid-Connected PV systems
- Open Access
- 30 September 2026
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 14 (3) , 738
Optimized Hybrid Energy Design for Load Management in Solar-Based Electric Vehicle Charging Stations in Rural Area
Among various energy-consuming sectors, transportation accounts for a significant contribution to global consumption, most of which is powered by conventional fossil-based sources. The growing urgency to address climate change, along with favorable international policies and technological advancements, has accelerated the transition to electric vehicles (EVs). However, this shift introduces new challenges, including the sustainable generation of electricity, managing increased loads on existing grids, and developing efficient EV charging infrastructure. In this paper, the design and optimization of a grid-integrated solar-lithium battery hybrid EV charging station tailored for rural areas. HOMER Grid and Pro software are used to design the proposed hybrid system, which comprises a 600 kW solar array, 5 lithium-ion batteries, a 25 kW battery, and a 76.2 kW bidirectional converter. The renewable fraction of the proposed system reached 100%, with an annual generation of 105319 kWh. This leads to a levelized cost of energy of $0.353/kWh, a net present cost of $462,686, and zero reliance on fossil fuels, which is suitable for both economic and environmental reasons.
- 30 September 2026
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 14 (3) , 738
Open AccessOptimized Hybrid Energy Design for Load Management in Solar-Based Electric Vehicle Charging Stations in Rural Area
Among various energy-consuming sectors, transportation accounts for a significant contribution to global consumption, most of which is powered by conventional fossil-based sources. The growing urgency to address climate change, along with favorable international policies and technological advancements, has accelerated the transition to electric vehicles (EVs). However, this shift introduces new challenges, including the sustainable generation of electricity, managing increased loads on existing grids, and developing efficient EV charging infrastructure. In this paper, the design and optimization of a grid-integrated solar-lithium battery hybrid EV charging station tailored for rural areas. HOMER Grid and Pro software are used to design the proposed hybrid system, which comprises a 600 kW solar array, 5 lithium-ion batteries, a 25 kW battery, and a 76.2 kW bidirectional converter. The renewable fraction of the proposed system reached 100%, with an annual generation of 105319 kWh. This leads to a levelized cost of energy of $0.353/kWh, a net present cost of $462,686, and zero reliance on fossil fuels, which is suitable for both economic and environmental reasons.
- Open Access
- 14 July 2026
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 34 (4) , 699-720
Parameter optimization of dual-QSG based PLL for real-time control of grid-connected EV chargers
Dual-Quadrature Signal Generator (D-QSG) based Phase lock loop (PLL) has been recently proposed to handle the nonideal grid voltage conditions. However, selecting the parameter for D-QSG based controller has been a great challenge, especially for higher-order systems. Inappropriate parameter selection tends to increase settling time both in terms of amplitude as well as harmonics attenuation. Hence, in the proposed work, the main focus is on parameter selection to achieve a faster response. Here, a fourth-order Quasi-Synchronous Generator has been realized by cascading the two nonidentical second order generalized integrators (NISOGIs). Furthermore, the parameters of both the NISOGIs are selected in such a way that gives a faster envelope around the 2\% settling time threshold in 24.4 ms. This method provides a more condensed distance within a Fourth-Order transfer function's poles, which eventually results in a faster reaction time. A suggested method has been used to regulate an EV charger during harmonics and voltage sag/swell instead of interfering with regular operation. Furthermore, the EV charger can readily adjust the level of active and reactive power in accordance with the established benchmarks while compensating for load harmonics. Both MATLAB/Simulink and Real-time platform provided by OPAL-rt prove the effectiveness of this approach.
- 14 July 2026
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 34 (4) , 699-720
Open AccessParameter optimization of dual-QSG based PLL for real-time control of grid-connected EV chargers
Dual-Quadrature Signal Generator (D-QSG) based Phase lock loop (PLL) has been recently proposed to handle the nonideal grid voltage conditions. However, selecting the parameter for D-QSG based controller has been a great challenge, especially for higher-order systems. Inappropriate parameter selection tends to increase settling time both in terms of amplitude as well as harmonics attenuation. Hence, in the proposed work, the main focus is on parameter selection to achieve a faster response. Here, a fourth-order Quasi-Synchronous Generator has been realized by cascading the two nonidentical second order generalized integrators (NISOGIs). Furthermore, the parameters of both the NISOGIs are selected in such a way that gives a faster envelope around the 2\% settling time threshold in 24.4 ms. This method provides a more condensed distance within a Fourth-Order transfer function's poles, which eventually results in a faster reaction time. A suggested method has been used to regulate an EV charger during harmonics and voltage sag/swell instead of interfering with regular operation. Furthermore, the EV charger can readily adjust the level of active and reactive power in accordance with the established benchmarks while compensating for load harmonics. Both MATLAB/Simulink and Real-time platform provided by OPAL-rt prove the effectiveness of this approach.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-10
Adaptive Quantum-Based Least Mean Fourth Control for Multisource Isolated Three-Phase Microgrids: Experimental Analysis and Performance Evaluation
This article presents an adaptive quantum normalized least-mean fourth (AQ-LMF) filtering control strategy to improve power quality (PQ) in standalone microgrids (MGs). Integrated with a voltage source converter (VSC), the controller provides fast dynamic response, enhanced stability, DC-offset rejection, reduced steady-state error, and minimized oscillations, while ensuring frequency regulation, load balancing, and harmonic mitigation under highly distorted loads. The algorithm employs error-correlation energy and signal normalization to accelerate convergence, reduce computational burden, and maintain stability at higher step sizes. A solar photovoltaic (PV) system is interfaced to the DC link through a boost converter using an incremental conductance (INC) maximum power point tracking method, while an energy storage system (ESS) connected via a bidirectional DC–DC converter balances power among solar, wind, and load demand during generation variability and load fluctuations. The proposed estimator reaches its steady-state tolerance band within two update cycles, with subsequent iterations confined within noise and quantization limits. Despite a load current total harmonic distortion (THD) of 29.61%, the AQ-LMF control limits supply current THD to 4.11%, complying with the IEEE-519 (<5%) standard. Experimental validation under dynamic conditions confirms the robustness and effectiveness of the proposed approach for reliable standalone MG operation.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-10
Adaptive Quantum-Based Least Mean Fourth Control for Multisource Isolated Three-Phase Microgrids: Experimental Analysis and Performance Evaluation
This article presents an adaptive quantum normalized least-mean fourth (AQ-LMF) filtering control strategy to improve power quality (PQ) in standalone microgrids (MGs). Integrated with a voltage source converter (VSC), the controller provides fast dynamic response, enhanced stability, DC-offset rejection, reduced steady-state error, and minimized oscillations, while ensuring frequency regulation, load balancing, and harmonic mitigation under highly distorted loads. The algorithm employs error-correlation energy and signal normalization to accelerate convergence, reduce computational burden, and maintain stability at higher step sizes. A solar photovoltaic (PV) system is interfaced to the DC link through a boost converter using an incremental conductance (INC) maximum power point tracking method, while an energy storage system (ESS) connected via a bidirectional DC–DC converter balances power among solar, wind, and load demand during generation variability and load fluctuations. The proposed estimator reaches its steady-state tolerance band within two update cycles, with subsequent iterations confined within noise and quantization limits. Despite a load current total harmonic distortion (THD) of 29.61%, the AQ-LMF control limits supply current THD to 4.11%, complying with the IEEE-519 (<5%) standard. Experimental validation under dynamic conditions confirms the robustness and effectiveness of the proposed approach for reliable standalone MG operation.
- Open Access
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Sigmoidal Least-Absolute-Difference-based Control Approach for Standalone Wind-Solar-Battery Hybrid Microgrid
This paper presents a wind-solar PV-battery-based standalone 3-phase microgrid system employing an adaptive sigmoidal least absolute difference control algorithm for voltage regulation, active/reactive power support, load balancing, and power-quality enhancement under intermittent operating conditions. The system integrates a SEIG-based wind-driven system, a solar PV array with incremental-conductance MPPT technique, and a bidirectional control-based battery storage system on a common DC-link side of the voltage source converter. To address these limitations, the proposed SLAD algorithm-based controller includes a sigmoidal nonlinear mapping within the absolute-difference learning structure to improve convergence stability, reduce sensitivity to deviations, and improve estimation accuracy under disturbances, and measurement uncertainty has been implemented. Comprehensive simulation and experimental results demonstrate stable DC-link regulation, balanced 3-phase currents, effective harmonic eradication, and robust dynamic performance during load perturbation, intermittency of solar & wind. This article compares least mean square, least absolute difference, second order sequence filter and SLAD-based controllers under steady-state & load perturbation utilizing control system & PQ indices. The proposed SLAD control approach has the fastest rise time (0.03s), low overshoot (2%), and shortest settling time, showing greater dynamic performance. The results confirm that the proposed control architecture ensures reliable standalone operation & improved PQ.
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSigmoidal Least-Absolute-Difference-based Control Approach for Standalone Wind-Solar-Battery Hybrid Microgrid
This paper presents a wind-solar PV-battery-based standalone 3-phase microgrid system employing an adaptive sigmoidal least absolute difference control algorithm for voltage regulation, active/reactive power support, load balancing, and power-quality enhancement under intermittent operating conditions. The system integrates a SEIG-based wind-driven system, a solar PV array with incremental-conductance MPPT technique, and a bidirectional control-based battery storage system on a common DC-link side of the voltage source converter. To address these limitations, the proposed SLAD algorithm-based controller includes a sigmoidal nonlinear mapping within the absolute-difference learning structure to improve convergence stability, reduce sensitivity to deviations, and improve estimation accuracy under disturbances, and measurement uncertainty has been implemented. Comprehensive simulation and experimental results demonstrate stable DC-link regulation, balanced 3-phase currents, effective harmonic eradication, and robust dynamic performance during load perturbation, intermittency of solar & wind. This article compares least mean square, least absolute difference, second order sequence filter and SLAD-based controllers under steady-state & load perturbation utilizing control system & PQ indices. The proposed SLAD control approach has the fastest rise time (0.03s), low overshoot (2%), and shortest settling time, showing greater dynamic performance. The results confirm that the proposed control architecture ensures reliable standalone operation & improved PQ.
- 2 February 2026
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 107 (2) , 565-577
Energy Management Through IoT-Based System: A Case Study
- 2 February 2026
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 107 (2) , 565-577
Energy Management Through IoT-Based System: A Case Study
- 9 January 2026
- Published by IGI Global Scientific Publishing
- p. 137-172
Next-Generation Control for Standalone SPV–WECS–BESS Using Hybrid Optimization
This chapter focuses on hybrid renewable energy sources (wind and solar) along with a battery energy storage system (BESS). To improve power quality, stability, and an uninterrupted power supply, the advanced control architecture is used. The hybrid system includes essential components such as incremental conductance (InC) maximum power point tracking (MPPT), Bidirectional DC-DC converter (BDC), battery management system (BMS), and voltage source converter (VSC) with an active power filter (APF). A hybrid PSO-GWO optimization technique is used to tune the PID controller, which is designed for dynamic conditions. The system is modelled in MATLAB/Simulink software, and the results confirm better performance, improved transient response, lower THD, and enhanced voltage stability when the conditions are change in solar irradiance, change in wind, and change in load. This method enhances the system reliability and efficiency of vital off-grid applications, including rural electrification and islanded microgrids.
- 9 January 2026
- Published by IGI Global Scientific Publishing
- p. 137-172
Next-Generation Control for Standalone SPV–WECS–BESS Using Hybrid Optimization
This chapter focuses on hybrid renewable energy sources (wind and solar) along with a battery energy storage system (BESS). To improve power quality, stability, and an uninterrupted power supply, the advanced control architecture is used. The hybrid system includes essential components such as incremental conductance (InC) maximum power point tracking (MPPT), Bidirectional DC-DC converter (BDC), battery management system (BMS), and voltage source converter (VSC) with an active power filter (APF). A hybrid PSO-GWO optimization technique is used to tune the PID controller, which is designed for dynamic conditions. The system is modelled in MATLAB/Simulink software, and the results confirm better performance, improved transient response, lower THD, and enhanced voltage stability when the conditions are change in solar irradiance, change in wind, and change in load. This method enhances the system reliability and efficiency of vital off-grid applications, including rural electrification and islanded microgrids.
- 11 November 2025
- Published by Springer Nature
- p. 111-122
Transitioning to Electric Mobility: Challenges, Opportunities, and Future Directions
- 11 November 2025
- Published by Springer Nature
- p. 111-122
Transitioning to Electric Mobility: Challenges, Opportunities, and Future Directions
- 11 November 2025
- Published by Springer Nature
- p. 1-16
Introduction of Fuel Cell-Based Hybrid Charging Infrastructure for Electric Vehicles
- 11 November 2025
- Published by Springer Nature
- p. 1-16
Introduction of Fuel Cell-Based Hybrid Charging Infrastructure for Electric Vehicles
- 11 November 2025
- Published by Elsevier in Renewable Energy Focus
- Vol. 56
Renewable-Based Hybrid Charging Infrastructure for Isolated Microgrids: Enhancing Power Quality and Supporting EV Integration
- 11 November 2025
- Published by Elsevier in Renewable Energy Focus
- Vol. 56
Renewable-Based Hybrid Charging Infrastructure for Isolated Microgrids: Enhancing Power Quality and Supporting EV Integration