Sa Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sa Ren has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Steve Goodacre
University of Sheffield
3 shared publications - Abdullah Pandor
Sheffield Centre for Health and Related Research (SCHARR), School of Medicine and Population Health, University of Sheffield, Sheffield, UK
2 shared publications - Catherine Fowler
The Aortic Dissection Charitable Trust, Chesterfield, UK
2 shared publications - Graham Cooper
Cardiology and Cardiothoracic Surgery, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
2 shared publications - Mark Clowes
Sheffield Centre for Health and Related Research (SCHARR), School of Medicine and Population Health, University of Sheffield, Sheffield, UK
2 shared publications - Matthew James Reed
Emergency Medicine Research Group Edinburgh (EMERGE), Royal Infirmary of Edinburgh, Edinburgh, UK
2 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by Springer Nature in Applied Network Science
Dynamic exponential random graph models with the fused lasso penalty
This paper investigates how the parameters governing network structure vary over time across a sequence of observed dynamic networks. We focus on ensembles of networks that exhibit sudden structural changes at certain time points but remain stable or undergo minimal changes in between. Many real-world networks, such as international trade networks and political co-voting networks, display this behaviour. Given a sequence of observed networks, our objective is to estimate the corresponding time-varying parameters of an exponential random graph model (ERGM) and identify periods of parameter stability as well as abrupt changes in the underlying network-generating mechanisms. To this end, we introduce a novel fused lasso exponential random graph model (FL-ERGM), which encourages similar parameter values across consecutive time points while allowing abrupt changes when supported by the data. To address the intractability of the ERGM likelihood, we adopt a pseudo-likelihood approximation and optimise the resulting penalised objective using the alternating direction method of multipliers (ADMM). We prove that the solution obtained by ADMM is equivalent to the optimal solution of the original objective function. Monte Carlo simulations demonstrate that FL-ERGM outperforms existing methods in estimating time-varying ERGM parameters and detecting structural changes. Applications to international trade and political co-voting networks reveal interpretable and contextually relevant patterns of temporal parameter variation.
- 6 November 2026
- Published by Springer Nature in Applied Network Science
Open AccessDynamic exponential random graph models with the fused lasso penalty
This paper investigates how the parameters governing network structure vary over time across a sequence of observed dynamic networks. We focus on ensembles of networks that exhibit sudden structural changes at certain time points but remain stable or undergo minimal changes in between. Many real-world networks, such as international trade networks and political co-voting networks, display this behaviour. Given a sequence of observed networks, our objective is to estimate the corresponding time-varying parameters of an exponential random graph model (ERGM) and identify periods of parameter stability as well as abrupt changes in the underlying network-generating mechanisms. To this end, we introduce a novel fused lasso exponential random graph model (FL-ERGM), which encourages similar parameter values across consecutive time points while allowing abrupt changes when supported by the data. To address the intractability of the ERGM likelihood, we adopt a pseudo-likelihood approximation and optimise the resulting penalised objective using the alternating direction method of multipliers (ADMM). We prove that the solution obtained by ADMM is equivalent to the optimal solution of the original objective function. Monte Carlo simulations demonstrate that FL-ERGM outperforms existing methods in estimating time-varying ERGM parameters and detecting structural changes. Applications to international trade and political co-voting networks reveal interpretable and contextually relevant patterns of temporal parameter variation.
- Open Access
- 1 January 2026
- Published by Becaris Publishing Limited in Journal of Comparative Effectiveness Research
- Vol. 15 (1) , e250095
Evaluating amyloid-beta as a surrogate endpoint in trials of anti-amyloid-beta drugs in Alzheimer’s disease: a Bayesian meta-analysis
Aim: The use of amyloid-beta (Aβ) clearance to support regulatory approvals of drugs in Alzheimer’s disease (AD) remains controversial. We evaluate Aβ as a potential trial-level surrogate endpoint for clinical function in AD. Materials & methods: Data on the effectiveness of anti-Aβ monoclonal antibodies (MABs) on Aβ and multiple clinical outcomes were identified from randomized controlled trials through a literature review. A Bayesian bivariate meta-analysis was used to evaluate Aβ as a surrogate endpoint for clinical function across all MABs and for each individual anti-Aβ MAB. The analysis for individual therapies was conducted in subgroups of treatments and by applying Bayesian hierarchical models to borrow information across treatments. Results: We identified 23 randomized controlled trials with 39 treatment contrasts for seven MABs. The surrogate relationship between treatment effects on Aβ and Clinical Dementia Rating-Sum of Boxes (CDR-SOB) across all MABs was strong: with a meaningful slope of 1.41 (0.60, 2.21) and small variance of 0.02 (0.00, 0.05). For individual treatments, the surrogate relationships were suboptimal, displaying large uncertainty. Sharing information across treatments considerably reduced the uncertainty, resulting in moderate surrogate relationships for aducanumab and lecanemab. No meaningful association was detected for other clinical outcomes, including Mini Mental State Examination and Alzheimer’s Disease Assessment Scale-Cognitive Subscale. Conclusion: Although our results from the analysis of data across all MABs suggested that Aβ was a potential surrogate endpoint for CDR-SOB, individually the surrogacy patterns varied across treatments and showed no evidence of association. Bayesian information-sharing revealed moderate surrogate relationship only for aducanumab and lecanemab.
- 1 January 2026
- Published by Becaris Publishing Limited in Journal of Comparative Effectiveness Research
- Vol. 15 (1) , e250095
Open AccessEvaluating amyloid-beta as a surrogate endpoint in trials of anti-amyloid-beta drugs in Alzheimer’s disease: a Bayesian meta-analysis
Aim: The use of amyloid-beta (Aβ) clearance to support regulatory approvals of drugs in Alzheimer’s disease (AD) remains controversial. We evaluate Aβ as a potential trial-level surrogate endpoint for clinical function in AD. Materials & methods: Data on the effectiveness of anti-Aβ monoclonal antibodies (MABs) on Aβ and multiple clinical outcomes were identified from randomized controlled trials through a literature review. A Bayesian bivariate meta-analysis was used to evaluate Aβ as a surrogate endpoint for clinical function across all MABs and for each individual anti-Aβ MAB. The analysis for individual therapies was conducted in subgroups of treatments and by applying Bayesian hierarchical models to borrow information across treatments. Results: We identified 23 randomized controlled trials with 39 treatment contrasts for seven MABs. The surrogate relationship between treatment effects on Aβ and Clinical Dementia Rating-Sum of Boxes (CDR-SOB) across all MABs was strong: with a meaningful slope of 1.41 (0.60, 2.21) and small variance of 0.02 (0.00, 0.05). For individual treatments, the surrogate relationships were suboptimal, displaying large uncertainty. Sharing information across treatments considerably reduced the uncertainty, resulting in moderate surrogate relationships for aducanumab and lecanemab. No meaningful association was detected for other clinical outcomes, including Mini Mental State Examination and Alzheimer’s Disease Assessment Scale-Cognitive Subscale. Conclusion: Although our results from the analysis of data across all MABs suggested that Aβ was a potential surrogate endpoint for CDR-SOB, individually the surrogacy patterns varied across treatments and showed no evidence of association. Bayesian information-sharing revealed moderate surrogate relationship only for aducanumab and lecanemab.
- Open Access
- 1 September 2025
- Published by National Institute for Health and Care Research in Health Technology Assessment
- p. 1-36
Diagnostic strategies for suspected acute aortic syndrome: systematic review, meta-analysis, decision-analytic modelling and value of information analysis
Background: Acute aortic syndrome is a life-threatening condition that requires urgent diagnosis with computed tomographic angiography. Diagnostic technologies, including clinical scores and biomarkers, can be used to select patients presenting with potential symptoms of acute aortic syndrome for computed tomographic angiography. Objectives: We aimed to estimate the accuracy of clinical scores and biomarkers for diagnosing acute aortic syndrome, the cost-effectiveness of alternative diagnostic strategies and the expected value of future research. Methods: We searched online databases from inception to February 2024, reference lists of included studies and existing systematic reviews. We included cohort studies evaluating the accuracy of clinical scores or biomarkers for diagnosing acute aortic syndrome compared with a reference standard. Two authors independently selected and extracted data. Risk of bias was appraised using the quality assessment of diagnostic accuracy studies-2 tool. Data were synthesised using either a multinomial or a bivariate normal meta-analysis model. We developed a decision-analytic model to simulate the management of a hypothetical cohort of patients attending hospital with possible acute aortic syndrome. We modelled diagnostic strategies that used the Aortic Dissection Detection Risk Score and D-dimer to select patients for computed tomographic angiography. We used estimates from our meta-analysis, existing literature and clinical experts to model the consequences of diagnostic strategies upon survival, health utility and healthcare costs. We estimated the incremental cost per quality-adjusted life-year gained by each strategy compared to the next most effective alternative on the efficiency frontier, and the expected value of perfect information. Results: Primary meta-analysis included 12 studies of Aortic Dissection Detection Risk Score alone, 6 studies of Aortic Dissection Detection Risk Score with D-dimer and 18 studies of D-dimer using the 500 ng/ml threshold. Sensitivities and specificities (95% credible intervals) were: Aortic Dissection Detection Risk Score > 0 94.6% (90% to 97.5%) and 34.7% (20.7% to 51.2%), Aortic Dissection Detection Risk Score > 1 43.4% (31.2% to 57.1%) and 89.3% (80.4% to 94.8%); Aortic Dissection Detection Risk Score > 0 or D-dimer > 500 ng/ml 99.8% (98.7% to 100%) and 21.8% (12.1% to 32.6%); Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml 98.3% (94.9% to 99.5%) and 51.4% (38.7% to 64.1%); Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml 93.1% (87.1% to 96.3%) and 67.1% (54.4% to 77.7%); and D-dimer alone 96.5% (94.8% to 98%) and 56.2% (48.3% to 63.9%). We identified 11 cohort studies of other biomarkers, but accuracy estimates were limited and inconsistent. Decision-analytic modelling showed that applying diagnostic strategies to an unselected population (acute aortic syndrome prevalence 0.26%) resulted in high rates of computed tomographic angiography, and only the strategy selecting patients with Aortic Dissection Detection Risk Score > 1 for computed tomographic angiography was cost-effective. If clinicians can select a population for investigation with higher acute aortic syndrome prevalence (0.61%), then using a strategy of Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml or a strategy of Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml to select patients for computed tomographic angiography is cost-effective and deliverable. At a threshold of £20,000/quality-adjusted life-year, population expected value of perfect information was around £17.75M. Limitations: Studies included in the meta-analysis showed substantial heterogeneity in estimates of specificity. In the modelling, there was substantial uncertainty around what constitutes suspected acute aortic syndrome and the effect of delayed diagnosis. Conclusions: The Aortic Dissection Detection Risk Score and D-dimer provide useful diagnostic information and may offer cost-effective strategies for selecting patients for computed tomographic angiography, but their role depends upon how clinicians identify suspected acute aortic syndrome. Future work: Primary research is required to compare different combinations of Aortic Dissection Detection Risk Score with D-dimer in practice, explore how suspected acute aortic syndrome is identified and evaluate alternative biomarkers. Funding: This synopsis presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR151853.
- 1 September 2025
- Published by National Institute for Health and Care Research in Health Technology Assessment
- p. 1-36
Open AccessDiagnostic strategies for suspected acute aortic syndrome: systematic review, meta-analysis, decision-analytic modelling and value of information analysis
Background: Acute aortic syndrome is a life-threatening condition that requires urgent diagnosis with computed tomographic angiography. Diagnostic technologies, including clinical scores and biomarkers, can be used to select patients presenting with potential symptoms of acute aortic syndrome for computed tomographic angiography. Objectives: We aimed to estimate the accuracy of clinical scores and biomarkers for diagnosing acute aortic syndrome, the cost-effectiveness of alternative diagnostic strategies and the expected value of future research. Methods: We searched online databases from inception to February 2024, reference lists of included studies and existing systematic reviews. We included cohort studies evaluating the accuracy of clinical scores or biomarkers for diagnosing acute aortic syndrome compared with a reference standard. Two authors independently selected and extracted data. Risk of bias was appraised using the quality assessment of diagnostic accuracy studies-2 tool. Data were synthesised using either a multinomial or a bivariate normal meta-analysis model. We developed a decision-analytic model to simulate the management of a hypothetical cohort of patients attending hospital with possible acute aortic syndrome. We modelled diagnostic strategies that used the Aortic Dissection Detection Risk Score and D-dimer to select patients for computed tomographic angiography. We used estimates from our meta-analysis, existing literature and clinical experts to model the consequences of diagnostic strategies upon survival, health utility and healthcare costs. We estimated the incremental cost per quality-adjusted life-year gained by each strategy compared to the next most effective alternative on the efficiency frontier, and the expected value of perfect information. Results: Primary meta-analysis included 12 studies of Aortic Dissection Detection Risk Score alone, 6 studies of Aortic Dissection Detection Risk Score with D-dimer and 18 studies of D-dimer using the 500 ng/ml threshold. Sensitivities and specificities (95% credible intervals) were: Aortic Dissection Detection Risk Score > 0 94.6% (90% to 97.5%) and 34.7% (20.7% to 51.2%), Aortic Dissection Detection Risk Score > 1 43.4% (31.2% to 57.1%) and 89.3% (80.4% to 94.8%); Aortic Dissection Detection Risk Score > 0 or D-dimer > 500 ng/ml 99.8% (98.7% to 100%) and 21.8% (12.1% to 32.6%); Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml 98.3% (94.9% to 99.5%) and 51.4% (38.7% to 64.1%); Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml 93.1% (87.1% to 96.3%) and 67.1% (54.4% to 77.7%); and D-dimer alone 96.5% (94.8% to 98%) and 56.2% (48.3% to 63.9%). We identified 11 cohort studies of other biomarkers, but accuracy estimates were limited and inconsistent. Decision-analytic modelling showed that applying diagnostic strategies to an unselected population (acute aortic syndrome prevalence 0.26%) resulted in high rates of computed tomographic angiography, and only the strategy selecting patients with Aortic Dissection Detection Risk Score > 1 for computed tomographic angiography was cost-effective. If clinicians can select a population for investigation with higher acute aortic syndrome prevalence (0.61%), then using a strategy of Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml or a strategy of Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml to select patients for computed tomographic angiography is cost-effective and deliverable. At a threshold of £20,000/quality-adjusted life-year, population expected value of perfect information was around £17.75M. Limitations: Studies included in the meta-analysis showed substantial heterogeneity in estimates of specificity. In the modelling, there was substantial uncertainty around what constitutes suspected acute aortic syndrome and the effect of delayed diagnosis. Conclusions: The Aortic Dissection Detection Risk Score and D-dimer provide useful diagnostic information and may offer cost-effective strategies for selecting patients for computed tomographic angiography, but their role depends upon how clinicians identify suspected acute aortic syndrome. Future work: Primary research is required to compare different combinations of Aortic Dissection Detection Risk Score with D-dimer in practice, explore how suspected acute aortic syndrome is identified and evaluate alternative biomarkers. Funding: This synopsis presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR151853.
- Open Access
- 1 September 2025
- Published by National Institute for Health and Care Research in Health Technology Assessment
Diagnostic strategies for suspected acute aortic syndrome: systematic review, meta-analysis, decision-analytic modelling and value of information analysis
Background: Acute aortic syndrome is a life-threatening condition that requires urgent diagnosis with computed tomographic angiography. Diagnostic technologies, including clinical scores and biomarkers, can be used to select patients presenting with potential symptoms of acute aortic syndrome for computed tomographic angiography. Objectives: We aimed to estimate the accuracy of clinical scores and biomarkers for diagnosing acute aortic syndrome, the cost-effectiveness of alternative diagnostic strategies and the expected value of future research. Methods: We searched online databases from inception to February 2024, reference lists of included studies and existing systematic reviews. We included cohort studies evaluating the accuracy of clinical scores or biomarkers for diagnosing acute aortic syndrome compared with a reference standard. Two authors independently selected and extracted data. Risk of bias was appraised using the quality assessment of diagnostic accuracy studies-2 tool. Data were synthesised using either a multinomial or a bivariate normal meta-analysis model. We developed a decision-analytic model to simulate the management of a hypothetical cohort of patients attending hospital with possible acute aortic syndrome. We modelled diagnostic strategies that used the Aortic Dissection Detection Risk Score and D-dimer to select patients for computed tomographic angiography. We used estimates from our meta-analysis, existing literature and clinical experts to model the consequences of diagnostic strategies upon survival, health utility and healthcare costs. We estimated the incremental cost per quality-adjusted life-year gained by each strategy compared to the next most effective alternative on the efficiency frontier, and the expected value of perfect information. Results: Primary meta-analysis included 12 studies of Aortic Dissection Detection Risk Score alone, 6 studies of Aortic Dissection Detection Risk Score with D-dimer and 18 studies of D-dimer using the 500 ng/ml threshold. Sensitivities and specificities (95% credible intervals) were: Aortic Dissection Detection Risk Score > 0 94.6% (90% to 97.5%) and 34.7% (20.7% to 51.2%), Aortic Dissection Detection Risk Score > 1 43.4% (31.2% to 57.1%) and 89.3% (80.4% to 94.8%); Aortic Dissection Detection Risk Score > 0 or D-dimer > 500 ng/ml 99.8% (98.7% to 100%) and 21.8% (12.1% to 32.6%); Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml 98.3% (94.9% to 99.5%) and 51.4% (38.7% to 64.1%); Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml 93.1% (87.1% to 96.3%) and 67.1% (54.4% to 77.7%); and D-dimer alone 96.5% (94.8% to 98%) and 56.2% (48.3% to 63.9%). We identified 11 cohort studies of other biomarkers, but accuracy estimates were limited and inconsistent. Decision-analytic modelling showed that applying diagnostic strategies to an unselected population (acute aortic syndrome prevalence 0.26%) resulted in high rates of computed tomographic angiography, and only the strategy selecting patients with Aortic Dissection Detection Risk Score > 1 for computed tomographic angiography was cost-effective. If clinicians can select a population for investigation with higher acute aortic syndrome prevalence (0.61%), then using a strategy of Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml or a strategy of Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml to select patients for computed tomographic angiography is cost-effective and deliverable. At a threshold of £20,000/quality-adjusted life-year, population expected value of perfect information was around £17.75M. Limitations: Studies included in the meta-analysis showed substantial heterogeneity in estimates of specificity. In the modelling, there was substantial uncertainty around what constitutes suspected acute aortic syndrome and the effect of delayed diagnosis. Conclusions: The Aortic Dissection Detection Risk Score and D-dimer provide useful diagnostic information and may offer cost-effective strategies for selecting patients for computed tomographic angiography, but their role depends upon how clinicians identify suspected acute aortic syndrome. Future work: Primary research is required to compare different combinations of Aortic Dissection Detection Risk Score with D-dimer in practice, explore how suspected acute aortic syndrome is identified and evaluate alternative biomarkers. Funding: This synopsis presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR151853.
- 1 September 2025
- Published by National Institute for Health and Care Research in Health Technology Assessment
Open AccessDiagnostic strategies for suspected acute aortic syndrome: systematic review, meta-analysis, decision-analytic modelling and value of information analysis
Background: Acute aortic syndrome is a life-threatening condition that requires urgent diagnosis with computed tomographic angiography. Diagnostic technologies, including clinical scores and biomarkers, can be used to select patients presenting with potential symptoms of acute aortic syndrome for computed tomographic angiography. Objectives: We aimed to estimate the accuracy of clinical scores and biomarkers for diagnosing acute aortic syndrome, the cost-effectiveness of alternative diagnostic strategies and the expected value of future research. Methods: We searched online databases from inception to February 2024, reference lists of included studies and existing systematic reviews. We included cohort studies evaluating the accuracy of clinical scores or biomarkers for diagnosing acute aortic syndrome compared with a reference standard. Two authors independently selected and extracted data. Risk of bias was appraised using the quality assessment of diagnostic accuracy studies-2 tool. Data were synthesised using either a multinomial or a bivariate normal meta-analysis model. We developed a decision-analytic model to simulate the management of a hypothetical cohort of patients attending hospital with possible acute aortic syndrome. We modelled diagnostic strategies that used the Aortic Dissection Detection Risk Score and D-dimer to select patients for computed tomographic angiography. We used estimates from our meta-analysis, existing literature and clinical experts to model the consequences of diagnostic strategies upon survival, health utility and healthcare costs. We estimated the incremental cost per quality-adjusted life-year gained by each strategy compared to the next most effective alternative on the efficiency frontier, and the expected value of perfect information. Results: Primary meta-analysis included 12 studies of Aortic Dissection Detection Risk Score alone, 6 studies of Aortic Dissection Detection Risk Score with D-dimer and 18 studies of D-dimer using the 500 ng/ml threshold. Sensitivities and specificities (95% credible intervals) were: Aortic Dissection Detection Risk Score > 0 94.6% (90% to 97.5%) and 34.7% (20.7% to 51.2%), Aortic Dissection Detection Risk Score > 1 43.4% (31.2% to 57.1%) and 89.3% (80.4% to 94.8%); Aortic Dissection Detection Risk Score > 0 or D-dimer > 500 ng/ml 99.8% (98.7% to 100%) and 21.8% (12.1% to 32.6%); Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml 98.3% (94.9% to 99.5%) and 51.4% (38.7% to 64.1%); Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml 93.1% (87.1% to 96.3%) and 67.1% (54.4% to 77.7%); and D-dimer alone 96.5% (94.8% to 98%) and 56.2% (48.3% to 63.9%). We identified 11 cohort studies of other biomarkers, but accuracy estimates were limited and inconsistent. Decision-analytic modelling showed that applying diagnostic strategies to an unselected population (acute aortic syndrome prevalence 0.26%) resulted in high rates of computed tomographic angiography, and only the strategy selecting patients with Aortic Dissection Detection Risk Score > 1 for computed tomographic angiography was cost-effective. If clinicians can select a population for investigation with higher acute aortic syndrome prevalence (0.61%), then using a strategy of Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml or a strategy of Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml to select patients for computed tomographic angiography is cost-effective and deliverable. At a threshold of £20,000/quality-adjusted life-year, population expected value of perfect information was around £17.75M. Limitations: Studies included in the meta-analysis showed substantial heterogeneity in estimates of specificity. In the modelling, there was substantial uncertainty around what constitutes suspected acute aortic syndrome and the effect of delayed diagnosis. Conclusions: The Aortic Dissection Detection Risk Score and D-dimer provide useful diagnostic information and may offer cost-effective strategies for selecting patients for computed tomographic angiography, but their role depends upon how clinicians identify suspected acute aortic syndrome. Future work: Primary research is required to compare different combinations of Aortic Dissection Detection Risk Score with D-dimer in practice, explore how suspected acute aortic syndrome is identified and evaluate alternative biomarkers. Funding: This synopsis presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR151853.
- Open Access
- 21 June 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (6) , e0304401
Diagnostic accuracy of the aortic dissection detection risk score alone or with D-dimer for acute aortic syndromes: Systematic review and meta-analysis
Objectives: To evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting acute aortic syndrome (AAS) in patients presenting with symptoms suggestive of AAS. Methods: We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic accuracy studies that assessed the use of ADD-RS alone or with D-Dimer for diagnosing AAS compared with a reference standard test (e.g. computer tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two reviewers independently selected and extracted data. Risk of bias was appraised using QUADAS-2 tool. Data were synthesised using hierarchical meta-analysis models. Results: We selected 13 studies from the 2017 citations identified, including six studies evaluating combinations of ADD-RS alongside D-dimer>500ng/L. Summary sensitivities and specificities (95% credible interval) were: ADD-RS>0 94.6% (90%, 97.5%) and 34.7% (20.7%, 51.2%), ADD-RS>1 43.4% (31.2%, 57.1%) and 89.3% (80.4%, 94.8%); ADD RS>0 or D-Dimer>500ng/L 99.8% (98.7%, 100%) and 21.8% (12.1%, 32.6%); ADD RS>1 or D-Dimer>500ng/L 98.3% (94.9%, 99.5%) and 51.4% (38.7%, 64.1%); ADD RS>1 or ADD RS = 1 with D-dimer>500ng/L 93.1% (87.1%, 96.3%) and 67.1% (54.4%, 77.7%). Conclusions: Combinations of ADD-RS and D-dimer can be used to select patients with suspected AAS for imaging with a range of trade-offs between sensitivity (93.1% to 99.8%) and specificity (21.8% to 67.1%).
- 21 June 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (6) , e0304401
Open AccessDiagnostic accuracy of the aortic dissection detection risk score alone or with D-dimer for acute aortic syndromes: Systematic review and meta-analysis
Objectives: To evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting acute aortic syndrome (AAS) in patients presenting with symptoms suggestive of AAS. Methods: We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic accuracy studies that assessed the use of ADD-RS alone or with D-Dimer for diagnosing AAS compared with a reference standard test (e.g. computer tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two reviewers independently selected and extracted data. Risk of bias was appraised using QUADAS-2 tool. Data were synthesised using hierarchical meta-analysis models. Results: We selected 13 studies from the 2017 citations identified, including six studies evaluating combinations of ADD-RS alongside D-dimer>500ng/L. Summary sensitivities and specificities (95% credible interval) were: ADD-RS>0 94.6% (90%, 97.5%) and 34.7% (20.7%, 51.2%), ADD-RS>1 43.4% (31.2%, 57.1%) and 89.3% (80.4%, 94.8%); ADD RS>0 or D-Dimer>500ng/L 99.8% (98.7%, 100%) and 21.8% (12.1%, 32.6%); ADD RS>1 or D-Dimer>500ng/L 98.3% (94.9%, 99.5%) and 51.4% (38.7%, 64.1%); ADD RS>1 or ADD RS = 1 with D-dimer>500ng/L 93.1% (87.1%, 96.3%) and 67.1% (54.4%, 77.7%). Conclusions: Combinations of ADD-RS and D-dimer can be used to select patients with suspected AAS for imaging with a range of trade-offs between sensitivity (93.1% to 99.8%) and specificity (21.8% to 67.1%).
- Open Access
- 28 March 2023
- Published by Elsevier in Social Networks
- Vol. 74, 156-165
Bayesian nonparametric mixtures of Exponential Random Graph Models for ensembles of networks
- 28 March 2023
- Published by Elsevier in Social Networks
- Vol. 74, 156-165
Open AccessBayesian nonparametric mixtures of Exponential Random Graph Models for ensembles of networks
- 3 November 2022
- Published by Springer Nature in Journal of Agricultural, Biological and Environmental Statistics
- Vol. 28 (2) , 375-376
Review of Handbook of Graphs and Networks in People Analytics: With Examples in R and Python by Keith McNulty
- 3 November 2022
- Published by Springer Nature in Journal of Agricultural, Biological and Environmental Statistics
- Vol. 28 (2) , 375-376
Review of Handbook of Graphs and Networks in People Analytics: With Examples in R and Python by Keith McNulty