Athanasios Batagiannis has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Open-Source Apparatus for Standardized Static Biomechanical Testing of Hip Implants

    by Styliani X. Stergiadou, Ilias Stavrakas, Ermioni D. Pasiou, Stavros K. Kourkoulis, Konstantinos Kalkanis, Aristeidis Zibis, Konstantinos Malizos, George Banis, Chara Koutsiatza, Maria Sarkiri, et al.

    This article presents the design, construction, and validation of an open-source apparatus for biomechanical testing of hip implants. The device enables controlled axial loading of implant constructs, addressing common limitations in terms of cost, complexity, and adaptability. The design emphasizes reproducibility, using widely available components and specimen-specific 3D-printed alignment tools, while ensuring high accuracy in load application and displacement measurement. The apparatus replicates physiological stance-phase loading (1.00× body weight (BW) axial, ~1.55× BW abductor, ~2.47× BW joint compression forces). The displacement values obtained by the validated finite element model and the Digital Image Correlation (DIC) technique on cadaveric specimens were compared and a mean displacement difference of 0.17 mm ± 0.09 mm was observed. Detailed build instructions and step-by-step operating protocols are provided, along with access to open-source CAD files. This work aims to facilitate broader access to customized biomechanical testing solutions for orthopedic research and education.

  • Open Access

    Does the ratio of stem‐to‐femur length matter? A validated finite element analysis

    by Georgios Banis, Charoula Kousiatza, Maria Sarkiri, Κostas Touloupas, Alexis Spiliotopoulos, Panagiotis Kontopoulos, Styliani Stergiadou, Michael Hantes, Aristeidis Zibis, Konstantinos Malizos, et al.

    Purpose: Total hip arthroplasty is among the most successful orthopedic procedures; however, approximately 10%–20% of patients require revision surgery within 15–20 years. Potential failure mechanisms at the bone–implant interface include stress shielding and excessive micromotion. This experimental work aims at examining the optimal ratio of femur length and stem length with respect to primary stability and stress shielding effect, employing a validated finite element analysis. Methods: One hundred human femora were reconstructed from computed tomography (CT) scans, and for each femur, 13 personalized cementless stems were designed with varying lengths (70–130 mm, in 5 mm increments), resulting in 1300 finite element models. Each model was analyzed under standardized joint and muscle loading conditions. The model was validated experimentally after cadaveric implantation with digital image correlation (DIC) under static loading. Primary outcomes included micromotion at the bone–implant interface and proximal stress shielding. Optimal stem length was determined as the ratio of stem‐to‐femur length that minimized the combined normalized scores of micromotion and stress shielding. The effect of stem‐to‐femur length ratio was analysed with linear regression. Results: The analysis revealed a correlation between femoral length and stem length. Longer stems provided better initial stability and reduced micromotion. On the other hand, shorter stems demonstrated less proximal stress shielding and a better stress distribution resembling that of the intact femur. The optimal stem length was found to be 18.5% ± 2.7% (mean ± SD) of the femur length in terms of the mean of calculated micromotions and stress shielding, indicating that personalized stem length selection can enhance the bone–implant osseointegration. Conclusion: The selection of a stem length that corresponds proportionally to femoral length can improve primary stability and stress shielding upon implantation, highlighting the importance of enhancing initial fixation in order to extend the lifespan of hip replacements. Level of Evidence: N/A.


  • Open Access

    Advanced Manufacturing Design of an Emergency Mechanical Ventilator via 3D Printing—Effective Crisis Response

    by Konstantinos Kalkanis, Kyriaki Kiskira, Panagiotis Papageorgas, Stavros D. Kaminaris, Dimitrios Piromalis, George Banis, Dimitrios Mpelesis, Athanasios Batagiannis

    Nowadays, there is a market need that is pushing manufacturers to support more sustainable product designs regardless of any crisis. Two important lessons that society inferred from the COVID-19 pandemic are that the industry needs an improved collaboration efficiency that can handle such emergencies and improve its resource conservation to avoid having shortages. Additive manufacturing technologies use 3D object scanners to direct hardware to deposit material, layer upon layer, in precise geometric shapes, and are positioned to provide a disruptive transformation in how products are designed and manufactured. They can provide for the planet in fighting against crisis from a materials and applications perspective. In this context, the optimization and production of emergency ventilators in health systems were investigated with plans for 3D printing received from the University of Illinois Urbana–Champaign. An evaluation of the printability of CAD files and a partial redesign to limit dimensional variability, acceptable surface finish, and a more efficient printing process were performed. Six parts of the design were redesigned to make printing easier, faster, and less expensive. In the case of the O2 inlet attachment, the necessary supports were difficult to remove due to the part’s geometry, leading to redesign. The modulator top and bottom part, the patient tee, the manometer body, and the pop-off valve cap were also redesigned in order to avoid dimensional variability and possible rough surfaces. Metallic and thermoplastic composite ventilators were produced and then tested in real operating conditions, such as in a hospital setting with a realistic oxygen supply. The preliminary findings are promising compared to the initial design, both in terms of construction quality and performance such as exhalation rate adjustment and emergency valve operation. Also, a combination of manufacturing technologies was evaluated. The modifications allowed optimal casting (injection molding) of the parts and therefore faster production, instead of printing each part, when high output is required.


  • Open Access

    CHIDOS: Customized Hip Implant Design & Optimization Service

    by Athanasios Batagiannis, Maria Sarkiri, Chara Kousiatza, George Banis, Darios Darvis Tabar

  • Open Access

    Design and Testing of a Disposable Flow Cuvette for Continuous Electroporation of a Bioreactor’s Initial Algae Cultivation

    by Georgios Banis, Maria Savvidou, Antonios Georgas, Athanasios Batagiannis, Fragiskos Kolisis, Angelo Ferraro, Evangelos Hristoforou

    Electroporation is a technique applied both in biomedical and biotechnological fields which uses a high-voltage electric current to temporarily destabilize the plasma membrane of living cells, permitting the introduction of small molecules as well as nucleic acids into the cytosol. Besides viral and chemical transfections, this method is a common way to manipulate living cells. However, the majority of electroporation machines available on the market can only work using batch-based cuvettes treating only a few micrograms of cells. To transform cells in the order of several grams in the quickest possible way, it is necessary to use a continuous-flow method. In this work, we present the design, electric and fluid dynamics simulations, construction and testing of a flow cuvette that can adapt to standard electroporator systems. The flow cuvette connected with a peristaltic pump was able to successfully electroporate 20 mL of medium containing microalgae cells in less than 5 min. Microalgae Scenedesmus almeriensis cells were transfected with a fluorescent siRNA oligo as well as magnetically transformed by introducing magnetic nanoparticles in their cytoplasm. The flow cuvette presented here offers a valid tool for the high-throughput transformation/transfection/transfer of both prokaryotic and eukaryotic organisms, especially suitable for bioreactor cultivation and other industrial biotechnological contexts.


  • 3D printing of an advanced design emergency mechanical ventilator, in response to the COVID 19 pandemic

    by K. Kalkanis, P. Papageorgas, S. D. Kaminaris, D. Piromalis, G. Banis, A. Batagiannis, D. Mpelesis

    Additive manufacturing is a rapidly evolving technological field, beyond he simple application of 3D printers, leading to an entirely new means of designing and manufacturing objects, paving the way for novel and unexplored possibilities. It is currently used in the production of mechanical components and tooling, medical and surgical implants and, also, to facilitate surgical design. The advantages stemming from this technology should be facilitated to combat the COVID-19 pandemic. With cases of respiratory failure and respiratory distress globally soaring and unavailability of standard automated ventilators in certain regions, the need to meet this demand is crucial. In this context, the research team considered it appropriate to move towards finding a solution to the problem of shortage in respirators in health systems worldwide. Having originally received plans for 3D printing from the University of Illinois, which produced disposable mechanical respirators with this technology, the possibility of optimizing and producing them at UNIWA was explored. The CAD files were analyzed in order to evaluate their printability resulting in partial redesign in order to limit dimensional variability, acceptable surface finish and make the printing process generally easier, faster, and less expensive. In addition, these modifications make the parts more suitable for casting, if high output is required. Metallic and thermoplastic composite respirators were produced and then tested in real operating conditions, i.e. with oxygen supply resembling a hospital environment. The initial results are considered positive, both in the quality of construction and in their performance. Furthermore, combination of manufacturing technologies is assessed, aiming at high output production.

  • Open Access

    Roadscanner: Feasibility Study and Development of a GNSS-Probe for Creating Digital Maps of High Accuracy and Integrity

    by Dimitris Vartziotis, Iraklis Goudas, Spyros Savvas, Athanasios Batagiannis, Florian Dittmann, Francesca Zanier


  • Piezo- and pyroelectric microscopy

    by Athanasios Batagiannis, Michael Wübbenhorst, Jürg Hulliger


  • Polymorphism, polar morphology and absolute structure determination of 4-iodo-4′-nitrobiphenyl (INBP)

    by Gaël Labat, Norwid-Rasmus Behrnd, Gaëtan Couderc, Michel Bonin, Julius Tsuwi, Athanasios Batagiannis, Ricarda Berger, Mariana Bertoni, Anna Prodi-Schwab, Jürg Hulliger

    4-Iodo-4′-nitrobiphenyl (INBP), a typical nonlinear optical molecule, features three polymorphs: Fdd2 as known before and two new forms, P2/c and P2. Monopolar crystals of the Fdd2 structure express a polar morphology and allowed an absolute structure determination. Iodo substituents cover the (001) and related faces. A negative pyroelectric coefficient was observed. The P2/c form was obtained from sublimation. Heating INBP (Fdd2) in the range of 150 to 180 °C ended in a second polar form (P2). DSC and dielectric measurements allowed us to assume a diffuse type of phase change from Fdd2 into P2. Lattice energy calculations for Fdd2 and P2/c yielded very similar energies. The twinning state observed for crystals not expressing polar symmetry is explained as a 50 : 50 % intergrowth of Fdd2 and P2/c. Periodic fragments allowed the close packing mode of all three polymorphs to be understood. A Hirshfeld surface analysis makes evident that apart from a strong linear synthon (I⋯NO2) other interactions in all three forms are very similar.


  • Polarity formation by a higher order interaction Markov-like chain

    by Mathias Rech, Athanasios Batagiannis, Jürg Hulliger