Anne Sophie Overgaard Olesen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anne Sophie Overgaard Olesen has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Kristina Miger
Department of Cardiology, Copenhagen University Hospital—Bispebjerg and Frederiksberg , Bispebjerg Bakke 23, 2400 Copenhagen
11 shared publications - Johannes Grand
Department of Cardiology Copenhagen University Hospital, Rigshospitalet Copenhagen Denmark
8 shared publications - Olav Wendelboe Nielsen
Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
7 shared publications Jens Jakob Thune
Affiliations Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark, Department of Cardiology, Copenhagen University Hospital – Frederiksberg and Bispebjerg, Copenhagen, Denmark
5 shared publications- Jens Jakob Thune
Department of Cardiology, Copenhagen University Hospital—Bispebjerg and Frederiksberg , Bispebjerg Bakke 23, 2400 Copenhagen
4 shared publications - Jens Petersen
Department of Computer Science, University of Copenhagen, Copenhagen, Denmark
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (8)
Artificial intelligence detection of heart failure on coronary computed tomography angiography: external validation in patients with non-ST-segment elevation acute coronary syndrome
Aims: Heart failure (HF) in non-ST-segment elevation acute coronary syndrome (NSTE-ACS) is associated with poor prognosis but often under-recognized. Coronary computed tomography angiography (CCTA), increasingly used in NSTE-ACS, contains cardiopulmonary features not routinely assessed for HF. We evaluated whether an artificial intelligence (AI) algorithm applied to CCTA could identify HF likelihood in NSTE-ACS. Methods and results: In this retrospective external validation study, the AI algorithm was applied without retraining or recalibration to CCTA scans from 1009 patients with NSTE-ACS in the VERDICT trial. Using a pre-specified threshold, patients were classified as low or high AI likelihood of HF. The primary outcome was HF during index hospitalization. The secondary outcome was post-discharge HF hospitalization among patients discharged alive without HF, with analyses adjusted for global registry of acute coronary events score >140 and severe coronary artery disease. Death was treated as a competing risk. Overall, 838 patients (83%) were classified as low AI likelihood and 171 (17%) as high. During index hospitalization, HF was diagnosed in 10 patients (1%) with low AI likelihood and 12 (7%) with high. Sensitivity was 55%, specificity 84%, positive predictive value 7%, and negative predictive value 99%. High AI likelihood was associated with increased risk of index HF (subdistribution hazard ratio, 5.39, 95% confidence interval (CI) 2.32–12.50). After discharge, HF hospitalization occurred in 25 patients (3%) with low AI likelihood and 14 (8%) with high. High AI likelihood remained associated with HF hospitalization (subdistribution hazard ratio 2.56, 95% CI 1.34–4.90). Conclusion: AI-based CCTA analysis identified a large low-risk subgroup and a smaller subgroup at increased HF risk, supporting further evaluation of opportunistic HF assessment from CCTA.
- 1 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (8)
Open AccessArtificial intelligence detection of heart failure on coronary computed tomography angiography: external validation in patients with non-ST-segment elevation acute coronary syndrome
Aims: Heart failure (HF) in non-ST-segment elevation acute coronary syndrome (NSTE-ACS) is associated with poor prognosis but often under-recognized. Coronary computed tomography angiography (CCTA), increasingly used in NSTE-ACS, contains cardiopulmonary features not routinely assessed for HF. We evaluated whether an artificial intelligence (AI) algorithm applied to CCTA could identify HF likelihood in NSTE-ACS. Methods and results: In this retrospective external validation study, the AI algorithm was applied without retraining or recalibration to CCTA scans from 1009 patients with NSTE-ACS in the VERDICT trial. Using a pre-specified threshold, patients were classified as low or high AI likelihood of HF. The primary outcome was HF during index hospitalization. The secondary outcome was post-discharge HF hospitalization among patients discharged alive without HF, with analyses adjusted for global registry of acute coronary events score >140 and severe coronary artery disease. Death was treated as a competing risk. Overall, 838 patients (83%) were classified as low AI likelihood and 171 (17%) as high. During index hospitalization, HF was diagnosed in 10 patients (1%) with low AI likelihood and 12 (7%) with high. Sensitivity was 55%, specificity 84%, positive predictive value 7%, and negative predictive value 99%. High AI likelihood was associated with increased risk of index HF (subdistribution hazard ratio, 5.39, 95% confidence interval (CI) 2.32–12.50). After discharge, HF hospitalization occurred in 25 patients (3%) with low AI likelihood and 14 (8%) with high. High AI likelihood remained associated with HF hospitalization (subdistribution hazard ratio 2.56, 95% CI 1.34–4.90). Conclusion: AI-based CCTA analysis identified a large low-risk subgroup and a smaller subgroup at increased HF risk, supporting further evaluation of opportunistic HF assessment from CCTA.
- Open Access
- 17 July 2026
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 70 (7) , e70306
Catheter‐Based Therapies for Intermediate‐High Risk Pulmonary Embolism: A Protocol for a Systematic Review With Bayesian Pairwise and Network Meta‐Analyses
Background: Intermediate‐high risk pulmonary embolism ( PE ) represents a clinically challenging subgroup of acute PE , characterized by right ventricular dysfunction and increased risk of hemodynamic deterioration despite treatment with anticoagulation therapy. Although systemic thrombolysis may provide more rapid reperfusion, its use is limited by an increased risk of major bleeding. Catheter‐based treatment strategies have emerged as potential alternatives, but their comparative efficacy and safety remain uncertain. Objective: To assess the benefits and harms of catheter‐based treatment strategies compared with contemporary control regimens, including standard anticoagulation with or without systemic thrombolysis, in patients with intermediate‐high risk PE . Methods: This protocol outlines a systematic review with Bayesian pairwise meta‐analysis and network meta‐analysis of randomized clinical trials evaluating catheter‐based therapies for hospitalized patients with intermediate‐high risk PE . Eligible interventions include catheter‐directed thrombolysis, ultrasound‐assisted thrombolysis, and catheter‐based embolectomy. Comparators may include standard anticoagulation alone or in combination with systemic thrombolysis or other active control regimens reflecting standard of care. Searches will be conducted in relevant databases, supplemented by trial registries. Two reviewers will independently screen studies, extract data, and assess risk of bias using the Cochrane Risk of Bias 2 tool. Bayesian pairwise meta‐analyses and network meta‐analysis will be performed using weakly informative priors to synthesize direct and indirect evidence across interventions. Results will be reported as posterior effect estimates with 95% credible intervals. The primary outcome will be all‐cause mortality. Secondary and exploratory outcomes include major bleeding as defined according to the criteria of the International Society on Thrombosis and Haemostasis within 7 days, hospital length of stay, and change in RV/LV ratio within 48 h. GRADE assessments will be performed where applicable. Discussion: This review will synthesize direct and indirect randomized evidence on catheter‐based treatment strategies for intermediate‐high risk PE . The findings may help clarify the role of these interventions in contemporary management, inform future guideline recommendations, and identify persistent evidence gaps requiring further large‐scale randomized trials.
- 17 July 2026
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 70 (7) , e70306
Open AccessCatheter‐Based Therapies for Intermediate‐High Risk Pulmonary Embolism: A Protocol for a Systematic Review With Bayesian Pairwise and Network Meta‐Analyses
Background: Intermediate‐high risk pulmonary embolism ( PE ) represents a clinically challenging subgroup of acute PE , characterized by right ventricular dysfunction and increased risk of hemodynamic deterioration despite treatment with anticoagulation therapy. Although systemic thrombolysis may provide more rapid reperfusion, its use is limited by an increased risk of major bleeding. Catheter‐based treatment strategies have emerged as potential alternatives, but their comparative efficacy and safety remain uncertain. Objective: To assess the benefits and harms of catheter‐based treatment strategies compared with contemporary control regimens, including standard anticoagulation with or without systemic thrombolysis, in patients with intermediate‐high risk PE . Methods: This protocol outlines a systematic review with Bayesian pairwise meta‐analysis and network meta‐analysis of randomized clinical trials evaluating catheter‐based therapies for hospitalized patients with intermediate‐high risk PE . Eligible interventions include catheter‐directed thrombolysis, ultrasound‐assisted thrombolysis, and catheter‐based embolectomy. Comparators may include standard anticoagulation alone or in combination with systemic thrombolysis or other active control regimens reflecting standard of care. Searches will be conducted in relevant databases, supplemented by trial registries. Two reviewers will independently screen studies, extract data, and assess risk of bias using the Cochrane Risk of Bias 2 tool. Bayesian pairwise meta‐analyses and network meta‐analysis will be performed using weakly informative priors to synthesize direct and indirect evidence across interventions. Results will be reported as posterior effect estimates with 95% credible intervals. The primary outcome will be all‐cause mortality. Secondary and exploratory outcomes include major bleeding as defined according to the criteria of the International Society on Thrombosis and Haemostasis within 7 days, hospital length of stay, and change in RV/LV ratio within 48 h. GRADE assessments will be performed where applicable. Discussion: This review will synthesize direct and indirect randomized evidence on catheter‐based treatment strategies for intermediate‐high risk PE . The findings may help clarify the role of these interventions in contemporary management, inform future guideline recommendations, and identify persistent evidence gaps requiring further large‐scale randomized trials.
- Open Access
- 22 May 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (5) , e0349791
Restrictive versus liberal oxygenation targets in patients with acute heart failure and pulmonary congestion–A protocol for a Randomized Controlled Trial (The REDOX-AHF trial)
Introduction: Acute heart failure (AHF) is the cause of one in twenty hospital admissions. Supplemental oxygen therapy is a routine treatment in the management of patients with dyspnea, including those with AHF. Current guidelines recommend oxygen therapy as part of the initial treatment, if peripheral oxygen saturation (SpO 2 ) is < 90% or partial pressure of arterial oxygen (PaO 2 ) is < 60 mmHg to correct hypoxemia. There is no clear evidence favoring restrictive or liberal oxygenation strategies in patients with acute heart failure. The aim of this study is to compare restrictive and liberal oxygenation strategies in patients hospitalized for acute heart failure. Methods: The study is an investigator-initiated, multicenter, prospective, double-blinded, randomized clinical trial. Patients are randomized in a 1:1 fashion to receive one of the two treatment-strategies: liberal oxygenation (SpO 2 target of 96%) or restrictive oxygenation (SpO 2 target of 90%). The intervention is administrated double-blinded using an automated oxygen administration device, titrating the oxygen supplementation towards the intended target SpO 2 without it being visible for patients, investigators or clinical staff. The primary outcome is pulmonary congestion, measured by remote dielectric sensing (ReDS) after 24 hours, adjusted for baseline measurements. Conclusion: This study will explore the current uncertainty regarding restrictive and liberal oxygenation targets in acute heart failure.
- 22 May 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (5) , e0349791
Open AccessRestrictive versus liberal oxygenation targets in patients with acute heart failure and pulmonary congestion–A protocol for a Randomized Controlled Trial (The REDOX-AHF trial)
Introduction: Acute heart failure (AHF) is the cause of one in twenty hospital admissions. Supplemental oxygen therapy is a routine treatment in the management of patients with dyspnea, including those with AHF. Current guidelines recommend oxygen therapy as part of the initial treatment, if peripheral oxygen saturation (SpO 2 ) is < 90% or partial pressure of arterial oxygen (PaO 2 ) is < 60 mmHg to correct hypoxemia. There is no clear evidence favoring restrictive or liberal oxygenation strategies in patients with acute heart failure. The aim of this study is to compare restrictive and liberal oxygenation strategies in patients hospitalized for acute heart failure. Methods: The study is an investigator-initiated, multicenter, prospective, double-blinded, randomized clinical trial. Patients are randomized in a 1:1 fashion to receive one of the two treatment-strategies: liberal oxygenation (SpO 2 target of 96%) or restrictive oxygenation (SpO 2 target of 90%). The intervention is administrated double-blinded using an automated oxygen administration device, titrating the oxygen supplementation towards the intended target SpO 2 without it being visible for patients, investigators or clinical staff. The primary outcome is pulmonary congestion, measured by remote dielectric sensing (ReDS) after 24 hours, adjusted for baseline measurements. Conclusion: This study will explore the current uncertainty regarding restrictive and liberal oxygenation targets in acute heart failure.
- Open Access
- 25 April 2026
- Published by Elsevier in American Heart Journal
- Vol. 299, 107461
Vasodilation, loop diuretics, or their combination in acute heart failure: Rationale and design of the randomized placebo-controlled DECONGEST-AHF trial
- 25 April 2026
- Published by Elsevier in American Heart Journal
- Vol. 299, 107461
Open AccessVasodilation, loop diuretics, or their combination in acute heart failure: Rationale and design of the randomized placebo-controlled DECONGEST-AHF trial
- 8 April 2026
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 28 (3) , 560-562
Secondary mitral and tricuspid regurgitation in early HFrEF: the impact of contemporary medical therapy
- 8 April 2026
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 28 (3) , 560-562
Secondary mitral and tricuspid regurgitation in early HFrEF: the impact of contemporary medical therapy
- 8 April 2026
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 28 (4) , 801-803
An alternative path in transthyretin amyloid cardiomyopathy
- 8 April 2026
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 28 (4) , 801-803
An alternative path in transthyretin amyloid cardiomyopathy
- 2 April 2026
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 25 (6) , 1168-1169
Remote dielectric sensing-guided heart failure management in primary care: early lessons from a feasibility study
- 2 April 2026
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 25 (6) , 1168-1169
Remote dielectric sensing-guided heart failure management in primary care: early lessons from a feasibility study
- 1 February 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (1) , e240529
Early Detection of Pulmonary Congestion Using Quantitative CT and Lung US in a Porcine Model
In a porcine model, quantitative CT showed high performance in early detection of pulmonary congestion, whereas US B-lines appeared in later stages but more effectively monitored regression.
- 1 February 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (1) , e240529
Early Detection of Pulmonary Congestion Using Quantitative CT and Lung US in a Porcine Model
In a porcine model, quantitative CT showed high performance in early detection of pulmonary congestion, whereas US B-lines appeared in later stages but more effectively monitored regression.
- Open Access
- 28 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (23) , 3047
Lung Ultrasound Versus Chest Radiography for Acute Heart Failure: Impact of Heart Failure History and Pleural Effusion
Background/Objectives: This is the first prospective, same-day, multi-modality comparison of lung ultrasound (LUS) and chest radiography (CXR) for detecting acute heart failure (AHF) in non-critical patients with dyspnoea, examining the impact of chronic heart failure and pleural effusion, using low-dose chest CT (LDCT) as an objective comparator, and cardiologists-adjudicated AHF as reference standard. Methods: An observational study of 240 consecutive non-critical patients ≥50 years admitted with dyspnoea was conducted. Unstable AHF cases were deemed ineligible. Each modality was evaluated at the population level with area under the curve (AUC), sensitivity, and specificity, and compared at the patient level using conditional odds ratio for the association to AHF adjudicated by blinded cardiologists. Congestion was defined by LUS as (a) ≥3 B-lines bilaterally, or (b) B-lines combined with pleural effusion, and (c) CXR, interpreted by two thoracic radiologists, using (d) LDCT as an objective comparator. Results: Among 240 patients (66 with cardiologist-adjudicated AHF, 58 with chronic heart failure), LUS (b) demonstrated a diagnostic accuracy at population level of AUC = 0.82 (sensitivity = 80%, specificity = 84%), while CXR (c) achieved AUC = 0.80 (sensitivity = 68%, specificity = 91%), with CXR showing a modest but statistically significant difference over LUS at the patient level (OR = 1.51, p = 0.03). Incorporating pleural effusion into LUS increased its AUC from 0.67 to 0.82 (a vs. b, p < 0.001). The objective comparator, LDCT (d), achieved an AUC = 0.92 (sensitivity = 74%, specificity = 96%). In patients with chronic heart failure, LUS (b) and CXR (c) performed comparably (p = 0.87), whereas in those without chronic heart failure, CXR was superior (p = 0.04). Conclusions: In non-critical, diagnostically challenging patients with dyspnoea, in whom critical AHF cases were not eligible, including pleural effusion improved LUS accuracy for AHF. Diagnostic performance differed by heart failure history, with CXR superior in new-onset heart failure, while LUS and CXR performed comparably in chronic heart failure.
- 28 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (23) , 3047
Open AccessLung Ultrasound Versus Chest Radiography for Acute Heart Failure: Impact of Heart Failure History and Pleural Effusion
Background/Objectives: This is the first prospective, same-day, multi-modality comparison of lung ultrasound (LUS) and chest radiography (CXR) for detecting acute heart failure (AHF) in non-critical patients with dyspnoea, examining the impact of chronic heart failure and pleural effusion, using low-dose chest CT (LDCT) as an objective comparator, and cardiologists-adjudicated AHF as reference standard. Methods: An observational study of 240 consecutive non-critical patients ≥50 years admitted with dyspnoea was conducted. Unstable AHF cases were deemed ineligible. Each modality was evaluated at the population level with area under the curve (AUC), sensitivity, and specificity, and compared at the patient level using conditional odds ratio for the association to AHF adjudicated by blinded cardiologists. Congestion was defined by LUS as (a) ≥3 B-lines bilaterally, or (b) B-lines combined with pleural effusion, and (c) CXR, interpreted by two thoracic radiologists, using (d) LDCT as an objective comparator. Results: Among 240 patients (66 with cardiologist-adjudicated AHF, 58 with chronic heart failure), LUS (b) demonstrated a diagnostic accuracy at population level of AUC = 0.82 (sensitivity = 80%, specificity = 84%), while CXR (c) achieved AUC = 0.80 (sensitivity = 68%, specificity = 91%), with CXR showing a modest but statistically significant difference over LUS at the patient level (OR = 1.51, p = 0.03). Incorporating pleural effusion into LUS increased its AUC from 0.67 to 0.82 (a vs. b, p < 0.001). The objective comparator, LDCT (d), achieved an AUC = 0.92 (sensitivity = 74%, specificity = 96%). In patients with chronic heart failure, LUS (b) and CXR (c) performed comparably (p = 0.87), whereas in those without chronic heart failure, CXR was superior (p = 0.04). Conclusions: In non-critical, diagnostically challenging patients with dyspnoea, in whom critical AHF cases were not eligible, including pleural effusion improved LUS accuracy for AHF. Diagnostic performance differed by heart failure history, with CXR superior in new-onset heart failure, while LUS and CXR performed comparably in chronic heart failure.
Combinations of diuretics for acute heart failure: a systematic review with network meta-analysis and trial sequential analysis
Background: Acute heart failure (AHF) is a severe clinical syndrome associated with high morbidity and mortality. Effective management of congestion is a primary treatment goal and often requires hospitalisation. While loop-diuretics remain the cornerstone of AHF therapy, the optimal combination of diuretics to an effective decongestion remains uncertain. This systematic review aims to evaluate the efficacy and safety of various diuretic combinations compared with usual care in AHF patients. Methods: The search was conducted across the databases: Medline, Embase, Latin American and Caribbean Health Sciences Literature, Web of Science, Scopus and The Cochrane Central Register of Controlled Trials. Network meta-analysis was used to compare the relative efficacy of different diuretic combinations. Trial sequential analysis (TSA) was conducted to evaluate the sufficiency of cumulative evidence for definitive conclusions. Risk of bias was assessed using the Cochrane Risk of Bias tool for randomised trials V.2. Statistical heterogeneity was evaluated via visual inspection of forest plots through the I² statistic. The primary outcome was all-cause mortality, and secondary outcomes included serious adverse events (SAEs), hospital readmissions and kidney failure. Exploratory outcomes included changes in body weight and urinary output. Results: 35 randomised clinical trials involving 11 743 patients were included. In pairwise meta-analyses, none of the diuretics demonstrated an influence on all-cause mortality, SAEs, hospital readmissions or kidney failure. Likewise, TSA showed no influence of combination therapy on mortality. Aggregate data meta-analyses revealed that combinations involving acetazolamide (−2.60 kg; 95% CI −4.23 to −0.97; p I 2 = 0.00%), thiazides (−0.80 kg; 95% CI −1.40 to −0.21; p=0.01; I 2 = 38.53%) and vaptans (−1.00 kg; 95% CI −1.53 to −0.48; p < 0.001; I 2 = 89.53%) caused significant in-hospital body weight reduction, indicating enhanced decongestion. Network meta-analysis showed similar results, and TSA indicated that there was enough information to accept secondary diuretics influencing decongestion. Conclusions: Combination diuretic therapy improves short-term decongestion but does not reduce all-cause mortality, SAEs, hospital readmissions or kidney failure in patients with AHF.
Combinations of diuretics for acute heart failure: a systematic review with network meta-analysis and trial sequential analysis
Background: Acute heart failure (AHF) is a severe clinical syndrome associated with high morbidity and mortality. Effective management of congestion is a primary treatment goal and often requires hospitalisation. While loop-diuretics remain the cornerstone of AHF therapy, the optimal combination of diuretics to an effective decongestion remains uncertain. This systematic review aims to evaluate the efficacy and safety of various diuretic combinations compared with usual care in AHF patients. Methods: The search was conducted across the databases: Medline, Embase, Latin American and Caribbean Health Sciences Literature, Web of Science, Scopus and The Cochrane Central Register of Controlled Trials. Network meta-analysis was used to compare the relative efficacy of different diuretic combinations. Trial sequential analysis (TSA) was conducted to evaluate the sufficiency of cumulative evidence for definitive conclusions. Risk of bias was assessed using the Cochrane Risk of Bias tool for randomised trials V.2. Statistical heterogeneity was evaluated via visual inspection of forest plots through the I² statistic. The primary outcome was all-cause mortality, and secondary outcomes included serious adverse events (SAEs), hospital readmissions and kidney failure. Exploratory outcomes included changes in body weight and urinary output. Results: 35 randomised clinical trials involving 11 743 patients were included. In pairwise meta-analyses, none of the diuretics demonstrated an influence on all-cause mortality, SAEs, hospital readmissions or kidney failure. Likewise, TSA showed no influence of combination therapy on mortality. Aggregate data meta-analyses revealed that combinations involving acetazolamide (−2.60 kg; 95% CI −4.23 to −0.97; p I 2 = 0.00%), thiazides (−0.80 kg; 95% CI −1.40 to −0.21; p=0.01; I 2 = 38.53%) and vaptans (−1.00 kg; 95% CI −1.53 to −0.48; p < 0.001; I 2 = 89.53%) caused significant in-hospital body weight reduction, indicating enhanced decongestion. Network meta-analysis showed similar results, and TSA indicated that there was enough information to accept secondary diuretics influencing decongestion. Conclusions: Combination diuretic therapy improves short-term decongestion but does not reduce all-cause mortality, SAEs, hospital readmissions or kidney failure in patients with AHF.