Lujian Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lujian Dai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications - Jun Zhao
Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China
2 shared publications - Bin Wei
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
1 shared publication - Chao Xing
Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China
1 shared publication - Chenmeng Xiang
Electric Power Research Institute of State Grid Hebei Electric Power Company, Shijiazhuang 050000, China
1 shared publication - Lili Wang
State Grid Hebei Electric Power Co., Ltd., Electric Power Research Institute, Shijiazhuang 310014, China
1 shared publication
Latest Publications
- Open Access
Impact of Adding Fast Switching Fault Current Limiter (FSFCL) to the Neutral Point of 220 kV Transformer
In recent years, as the power grid continues to expand, the issue of asymmetrical short-circuit currents exceeding limits on the 220 kV medium-voltage side has become increasingly severe, and traditional current-limiting methods have certain limitations. Therefore, this paper explores the potential benefits and feasibility of installing a Fast Switching Fault Current Limiter (FSFCL) at the neutral point of a 220 kV transformer to effectively limit asymmetrical short-circuit currents on the medium-voltage side. The paper first analyzes the current-limiting performance of the FSFCL under different installation configurations, transformer operating conditions, and fault conditions through theoretical calculations. Subsequently, through simulation studies, the impact of different limiting reactance values on the overvoltage effect at the neutral point is discussed. The results show that the installation of the FSFCL has a significant effect on suppressing the asymmetrical short-circuit current on the medium-voltage side of the transformer, but this measure has also led to an increase in the voltage at the grounded neutral point. Finally, taking the No. 2 main transformer of a certain 220 kV substation as an example, to achieve the expected current-limiting effect, the limiting reactance value of the FSFCL needs to be at least 4 ohms. At this reactance value, the overvoltage level at the neutral point remains well below the withstand limit of its insulating material. Additionally, given the existing overvoltage protection devices at the neutral point, no further overvoltage protection measures are required.
Open AccessImpact of Adding Fast Switching Fault Current Limiter (FSFCL) to the Neutral Point of 220 kV Transformer
In recent years, as the power grid continues to expand, the issue of asymmetrical short-circuit currents exceeding limits on the 220 kV medium-voltage side has become increasingly severe, and traditional current-limiting methods have certain limitations. Therefore, this paper explores the potential benefits and feasibility of installing a Fast Switching Fault Current Limiter (FSFCL) at the neutral point of a 220 kV transformer to effectively limit asymmetrical short-circuit currents on the medium-voltage side. The paper first analyzes the current-limiting performance of the FSFCL under different installation configurations, transformer operating conditions, and fault conditions through theoretical calculations. Subsequently, through simulation studies, the impact of different limiting reactance values on the overvoltage effect at the neutral point is discussed. The results show that the installation of the FSFCL has a significant effect on suppressing the asymmetrical short-circuit current on the medium-voltage side of the transformer, but this measure has also led to an increase in the voltage at the grounded neutral point. Finally, taking the No. 2 main transformer of a certain 220 kV substation as an example, to achieve the expected current-limiting effect, the limiting reactance value of the FSFCL needs to be at least 4 ohms. At this reactance value, the overvoltage level at the neutral point remains well below the withstand limit of its insulating material. Additionally, given the existing overvoltage protection devices at the neutral point, no further overvoltage protection measures are required.
- Open Access
Phase Stability Control of Optical Fiber Partial Discharge Ultrasonic Sensing System
Optic fiber interferometers are highly sensitive ultrasonic sensors for partial discharge detection. However, low-frequency vibration and environmental noise will disturb the sensors in the field, and cause a phase fading suppression effect that reduces sensitivity. This paper analyzed the problems existing in the phase feedback control system based on PZT, and an improved scheme incorporating a high-frequency carrier phase demodulation is proposed. Based on an acousto-optic modulator, the proposed phase feedback control system overcomes the phase fading suppression effect. A test is carried out on an ultrasonic calibration platform and a transformer oil discharge platform. The test results show that the stability of the improved phase demodulation system has been significantly improved, and meets the requirements of field applications. Compared with the signal-to-noise ratio at the time of phase fading of the system before the improvement, the signal-to-noise ratio of the improved system is improved by 69 dB.
Open AccessPhase Stability Control of Optical Fiber Partial Discharge Ultrasonic Sensing System
Optic fiber interferometers are highly sensitive ultrasonic sensors for partial discharge detection. However, low-frequency vibration and environmental noise will disturb the sensors in the field, and cause a phase fading suppression effect that reduces sensitivity. This paper analyzed the problems existing in the phase feedback control system based on PZT, and an improved scheme incorporating a high-frequency carrier phase demodulation is proposed. Based on an acousto-optic modulator, the proposed phase feedback control system overcomes the phase fading suppression effect. A test is carried out on an ultrasonic calibration platform and a transformer oil discharge platform. The test results show that the stability of the improved phase demodulation system has been significantly improved, and meets the requirements of field applications. Compared with the signal-to-noise ratio at the time of phase fading of the system before the improvement, the signal-to-noise ratio of the improved system is improved by 69 dB.