Ranjit Hawaldar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ranjit Hawaldar has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Chandan Dutta
CSIR-National Metallurgical Laboratory
2 shared publications - Jayendra Kumar
Department of Electronics and Communication Engineering, National Institute of Technology Jamshedpur, Jamshedpur, India
2 shared publications - Sarmishtha Palit Sagar
CSIR-National Metallurgical Laboratory
2 shared publications - Tarun Kumar Das
Advanced Materials and Processes (AMP) Division, CSIR-NML, Jamshedpur, India
2 shared publications - Abhijeet Kumar
Department of Chemistry School of Physical Sciences Mahatma Gandhi Central University Motihari Bihar 845401 India
1 shared publication - Budhendra Singh
TEMA-NRD, Mechanical Engineering Department, Aveiro Institute of Nanotechnology (AIN), University of Aveiro, Aveiro 3810-193, Portugal
1 shared publication
Latest Publications
- 4 November 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (2) , 2909-2920
Exploring the structural and electrical trends in Mo2+ substituted Ba0.7Gd0.3MoxF12-xO19 Hexaferrite
- 4 November 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (2) , 2909-2920
Exploring the structural and electrical trends in Mo2+ substituted Ba0.7Gd0.3MoxF12-xO19 Hexaferrite
- 8 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (8) , 8451-8458
NDE-Based Failure Analysis of an LTCC-Eddy Current Sensor Exposed to High Temperature Using 3-D X-Ray μ-CT
Sensors based on Low Temperature Co-fired Ceramic (LTCC) technology have shown great potential for in-situ Structural Health Monitoring (SHM) of engineering components exposed to high temperatures (HT) [1]. LTCC is a unique of its kind materials technology offering significant advantages for the development of micro-systems with integrated sensors. Nevertheless, there are still metrological issues like thermal and mechanical stresses associated with the fabrication process and subsequently the sensor fails while in use. This communication deals with the Non Destructive Evaluation (NDE) based failure analysis of an LTCC-based Eddy Current (EC) sensor exposed to HT. It aims at monitoring the in-situ performance and efficacy of the sensor exposed to HT for prolonged duration. The sensor was instrumented and placed inside the furnace (~ 650 °C) and in-situ EC response was monitored using an automated EC measurement set-up. We found that the sensor failed to operate by losing its electrical attributes after ~ 350 hours of continuous operation. Subsequently, a detailed investigation on NDE-based failure analysis of the sensor was carried out using an ultra-high resolution 3D X-ray μ-Computer Tomography (μ-CT) imaging system. The most common flaws include alignment errors, conductor swelling, conductor creeps, layer shrinkage, interconnect via voids, coil expansion and micro-cracks on conductor tracks and pads. A comparison study is drawn to create a database that will lead to optimizing the fabrication process flow and setting operational limits of the LTCC sensor.
- 8 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (8) , 8451-8458
NDE-Based Failure Analysis of an LTCC-Eddy Current Sensor Exposed to High Temperature Using 3-D X-Ray μ-CT
Sensors based on Low Temperature Co-fired Ceramic (LTCC) technology have shown great potential for in-situ Structural Health Monitoring (SHM) of engineering components exposed to high temperatures (HT) [1]. LTCC is a unique of its kind materials technology offering significant advantages for the development of micro-systems with integrated sensors. Nevertheless, there are still metrological issues like thermal and mechanical stresses associated with the fabrication process and subsequently the sensor fails while in use. This communication deals with the Non Destructive Evaluation (NDE) based failure analysis of an LTCC-based Eddy Current (EC) sensor exposed to HT. It aims at monitoring the in-situ performance and efficacy of the sensor exposed to HT for prolonged duration. The sensor was instrumented and placed inside the furnace (~ 650 °C) and in-situ EC response was monitored using an automated EC measurement set-up. We found that the sensor failed to operate by losing its electrical attributes after ~ 350 hours of continuous operation. Subsequently, a detailed investigation on NDE-based failure analysis of the sensor was carried out using an ultra-high resolution 3D X-ray μ-Computer Tomography (μ-CT) imaging system. The most common flaws include alignment errors, conductor swelling, conductor creeps, layer shrinkage, interconnect via voids, coil expansion and micro-cracks on conductor tracks and pads. A comparison study is drawn to create a database that will lead to optimizing the fabrication process flow and setting operational limits of the LTCC sensor.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Delineation of Parametric Controls on LTCC-Based Eddy Current Sensor Exposed to High Temperature
The investigation is focused on the parametric evaluation of a micro-fabricated Multi-Layer Planar (MLP) coil exposed to high temperature (≥ 600 °C). It can potentially be used as eddy current (EC) sensor for in-situ structural health monitoring (SHM) of critical engineering components. A detailed analysis of various contributing factors that affects the performance of the MLP coil is discussed. The coil is micro-fabricated on a ceramic substrate (DuPont L951 green tape) using state-of-the-art Low-Temperature Co-Fired-Ceramic (LTCC) technique. The stacked layer configuration (30 layers) soars the performance of the coil in terms of sensitivity and robustness. Emphasis is given on the performance both for dynamic & prolonged static thermal exposure. Delineation of electrical parameters particularly the series inductance (LS) of the sensor is found to be stable (~ 130 μH ±3%) up to 600 °C beyond which up to 800 °C, there is a decreasing trend (~ 70 μH ±3%). Also, the sensor shows stable and consistent behaviour with a nominal deviation of ± 1 % during prolonged thermal exposure. These findings throw light on the application of the MLP coil for in-situ SHM of critical engineering components exposed to high temperature.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Delineation of Parametric Controls on LTCC-Based Eddy Current Sensor Exposed to High Temperature
The investigation is focused on the parametric evaluation of a micro-fabricated Multi-Layer Planar (MLP) coil exposed to high temperature (≥ 600 °C). It can potentially be used as eddy current (EC) sensor for in-situ structural health monitoring (SHM) of critical engineering components. A detailed analysis of various contributing factors that affects the performance of the MLP coil is discussed. The coil is micro-fabricated on a ceramic substrate (DuPont L951 green tape) using state-of-the-art Low-Temperature Co-Fired-Ceramic (LTCC) technique. The stacked layer configuration (30 layers) soars the performance of the coil in terms of sensitivity and robustness. Emphasis is given on the performance both for dynamic & prolonged static thermal exposure. Delineation of electrical parameters particularly the series inductance (LS) of the sensor is found to be stable (~ 130 μH ±3%) up to 600 °C beyond which up to 800 °C, there is a decreasing trend (~ 70 μH ±3%). Also, the sensor shows stable and consistent behaviour with a nominal deviation of ± 1 % during prolonged thermal exposure. These findings throw light on the application of the MLP coil for in-situ SHM of critical engineering components exposed to high temperature.
- 4 April 2022
- Published by Walter de Gruyter GmbH
- p. 229-238
Chapter 8 Microbiology as an occupational hazard: risk and challenges
A large number of cases have been reported worldwide regarding occupationally acquired microbial diseases. These cases are of major concern because they have potential to cause pandemics. Among the various occupational health hazards, the most serious one is the risk caused by biological agents like viruses, fungi, bacteria and human parasites. The direct/indirect contact with animals, infectious materials and cultures also pose a health hazard. In current chapter, role of microbiology hazards in various occupations, occupational zoonotic diseases, legislation, safety policies and biosafety measures in microbiological laboratories have been discussed.
- 4 April 2022
- Published by Walter de Gruyter GmbH
- p. 229-238
Chapter 8 Microbiology as an occupational hazard: risk and challenges
A large number of cases have been reported worldwide regarding occupationally acquired microbial diseases. These cases are of major concern because they have potential to cause pandemics. Among the various occupational health hazards, the most serious one is the risk caused by biological agents like viruses, fungi, bacteria and human parasites. The direct/indirect contact with animals, infectious materials and cultures also pose a health hazard. In current chapter, role of microbiology hazards in various occupations, occupational zoonotic diseases, legislation, safety policies and biosafety measures in microbiological laboratories have been discussed.
- 1 July 2006
- Published by Elsevier in Materials Science and Engineering: B
- Vol. 132 (1-2) , 170-173
Nanoscale multilayer PbS thin films fabricated by liquid–liquid interface reaction technique for solar photovoltaic applications
- 1 July 2006
- Published by Elsevier in Materials Science and Engineering: B
- Vol. 132 (1-2) , 170-173
Nanoscale multilayer PbS thin films fabricated by liquid–liquid interface reaction technique for solar photovoltaic applications