EPEetu Parkkinen

Eetu Parkkinen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eetu Parkkinen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multipoint Raman Spectrometer Based on a Time-Resolved CMOS SPAD Sensor

    by Tuomo Talala, Ville A. Kaikkonen, Eetu Virta, Anssi J. Mäkynen, Ilkka Nissinen

    The potential of in-line Raman spectrometers for process monitoring applications has been shown for many industrial processes, but in most cases, only one measurement point has been monitored by one spectrometer. In this letter, we describe and demonstrate a novel, time-resolved method for measuring Raman spectra and fluorescence lifetimes from multiple points using a single excitation source and a single spectrometer. This technique is based on a combination of a time-resolved CMOS SPAD (single-photon avalanche diode) line sensor and a fitting optical light guiding system. The line sensor is designed to make multiple individual measurements at intervals of tens of nanoseconds and the optical light guiding system, in turn, produces matching temporal differences for optical signals from different measurement points. Thereby, signals from different points are distinguished in the time domain. A combined Raman and fluorescence lifetime monitoring of two measurement points was demonstrated with an oil-ethanol emulsion sample.


  • Open Access

    CMOS SPAD Line Sensor With Fine-Tunable Parallel Connected Time-to-Digital Converters for Raman Spectroscopy

    by Tuomo Talala, Eetu Parkkinen, Ilkka Nissinen

    A 256-channel single-photon avalanche diode (SPAD) line sensor was designed for time-resolved Raman spectroscopy in 110-nm CMOS technology. The line sensor consists of an 8 $\times$ 256 SPAD array and 256 parallel connected time-to-digital converters (TDCs). The adjustable temporal resolution and dynamic range of TDCs are 25.6–65 ps and 3.2–8.2 ns, respectively. The median timing skew along 256 channels is 43.7 ps, and TDC bin boundaries can be fine-tuned at the ps-level to enable precise timing skew compensation. The sensor is capable of real-time dark count measurement (two dark measurements for each excitation pulse) that gives accurate data for dark count compensation without any increment in measurement time. The maximum excitation pulse rate with real-time dark count measurement is 680 kHz. Raman spectra of six different samples were measured to prove the performance of the sensor in time-resolved Raman spectroscopy.