Ming Qu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ming Qu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Tao Ding
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
6 shared publications - Mohammad Shahidehpour
Illinois Institute of Technology
4 shared publications - Chenggang Mu
Department of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Yuge Sun
School of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Kai Pan
Faculty of Business, The Hong Kong Polytechnic University, Kowloon, Hong Kong
2 shared publications - Xiaosheng Zhang
School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications
Latest Publications
- 2 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network Science and Engineering
- Vol. 11 (6) , 5487-5502
Adjustable Robust Low-Carbon Unit Commitment With Nonanticipativity by Linear Programming
Thermal power generation is the main source of carbon emissions. Adopting low-carbon dispatching and developing renewable energy sources (RESs) are effective ways to reduce carbon emissions. This article constructs a mixed-integer programming (MIP) model of low-carbon full-scenario unit commitment with nonanticipativity. To overcome the curse of dimensionality problem caused by the use of a massive number of scenarios, we employ the adjustable robust optimization approach (AROA) to reformulate the full-scenario unit commitment as a deterministic robust model. In addition, we establish the precise adjustable robust convex hull of generation constraints in a higher dimensional space and generate a relaxed linear programming (LP) formulation of the original MIP model. Then, we design a heuristic method for obtaining a near-optimal feasible solution by converting a large-scale MIP into an LP model that can be solved in polynomial time. The numerical experiments presented in this article demonstrate the effectiveness and efficiency of the proposed method.
- 2 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Network Science and Engineering
- Vol. 11 (6) , 5487-5502
Adjustable Robust Low-Carbon Unit Commitment With Nonanticipativity by Linear Programming
Thermal power generation is the main source of carbon emissions. Adopting low-carbon dispatching and developing renewable energy sources (RESs) are effective ways to reduce carbon emissions. This article constructs a mixed-integer programming (MIP) model of low-carbon full-scenario unit commitment with nonanticipativity. To overcome the curse of dimensionality problem caused by the use of a massive number of scenarios, we employ the adjustable robust optimization approach (AROA) to reformulate the full-scenario unit commitment as a deterministic robust model. In addition, we establish the precise adjustable robust convex hull of generation constraints in a higher dimensional space and generate a relaxed linear programming (LP) formulation of the original MIP model. Then, we design a heuristic method for obtaining a near-optimal feasible solution by converting a large-scale MIP into an LP model that can be solved in polynomial time. The numerical experiments presented in this article demonstrate the effectiveness and efficiency of the proposed method.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 21 (2) , 1754-1766
Linearization Method for Large-Scale Hydro-Thermal Security-Constrained Unit Commitment
Security-constrained unit commitment (SCUC) is one of the most fundamental optimization problems in power systems. The objective of SCUC is to minimize the operating cost while respecting both system-wide and generator-specific constraints. It leads to a large-scale and mixed-integer programming (MIP) model with a large number of binary decision variables which is difficult to solve. This paper, based on the convex hull theory of single-unit, proposes a linearization method for the hydro-thermal SCUC problem with decoupled thermal units and variable-head hydro units. Then, the strategy of embedding two types of convex hulls in a multi-unit commitment and the heuristic method of constructing a feasible solution are designed, by which the multi-UC is approximated from large-scale mixed-integer programming to linear programming that can be solved in polynomial time. Finally, we theoretically prove that the optimal solution of the proposed LP model is always better than that of the Lagrangian Relaxation model. Numerical experiments on several large-scale test systems demonstrate the effectiveness and efficiency of the proposed method. Note to Practitioners —This paper proposes a linear programming model for the SCUC problem by lifting up to a higher-dimensional space. It realizes an important innovation in reducing the computational complexity of SCUC from the perspective of linearization. The proposed method can be well applied to large-scale long-term unit commitment problems. To better use this method, the following two properties should be highlighted: 1) the error of the proposed method is less than the Lagrangian relaxation method and decreases with the increasing system scales and 2) the computational efficiency of the proposed method is 10-100 times faster than that of the MIP model. We have tested many practical power systems and find that the error of the proposed LP model is usually very small compared with the precise MIP while the computational performance is significantly improved. In some practical cases, the decision makers usually do not want to find the precise optimal solution while only an approximation under a fast speed, because the boundary condition is imprecise. The proposed method is useful. Besides, for the cases that need the precise optimal solution, the proposed method can provide a high-quality initial solution for the MIP model to accelerate the convergence.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 21 (2) , 1754-1766
Linearization Method for Large-Scale Hydro-Thermal Security-Constrained Unit Commitment
Security-constrained unit commitment (SCUC) is one of the most fundamental optimization problems in power systems. The objective of SCUC is to minimize the operating cost while respecting both system-wide and generator-specific constraints. It leads to a large-scale and mixed-integer programming (MIP) model with a large number of binary decision variables which is difficult to solve. This paper, based on the convex hull theory of single-unit, proposes a linearization method for the hydro-thermal SCUC problem with decoupled thermal units and variable-head hydro units. Then, the strategy of embedding two types of convex hulls in a multi-unit commitment and the heuristic method of constructing a feasible solution are designed, by which the multi-UC is approximated from large-scale mixed-integer programming to linear programming that can be solved in polynomial time. Finally, we theoretically prove that the optimal solution of the proposed LP model is always better than that of the Lagrangian Relaxation model. Numerical experiments on several large-scale test systems demonstrate the effectiveness and efficiency of the proposed method. Note to Practitioners —This paper proposes a linear programming model for the SCUC problem by lifting up to a higher-dimensional space. It realizes an important innovation in reducing the computational complexity of SCUC from the perspective of linearization. The proposed method can be well applied to large-scale long-term unit commitment problems. To better use this method, the following two properties should be highlighted: 1) the error of the proposed method is less than the Lagrangian relaxation method and decreases with the increasing system scales and 2) the computational efficiency of the proposed method is 10-100 times faster than that of the MIP model. We have tested many practical power systems and find that the error of the proposed LP model is usually very small compared with the precise MIP while the computational performance is significantly improved. In some practical cases, the decision makers usually do not want to find the precise optimal solution while only an approximation under a fast speed, because the boundary condition is imprecise. The proposed method is useful. Besides, for the cases that need the precise optimal solution, the proposed method can provide a high-quality initial solution for the MIP model to accelerate the convergence.
- 20 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (2) , 1755-1758
An Algorithmic Approach for Inner Max-Min Model Under Norm-2 Type Uncertainty Set in Data-Driven Distributionally Robust Optimization
To accelerate the computational speed of data-driven distributionally robust optimization (DDRO), this letter presents a novel algorithmic approach to solve the inner max-min model under norm-2 type uncertainty set in DDRO. The proposed method can solve the problem in an easily implemented way instead of a time-consuming optimization process using commercial solvers. Comparisons of computational time between the algorithmic approach and optimization solvers verify the effectiveness of the proposed method.
- 20 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (2) , 1755-1758
An Algorithmic Approach for Inner Max-Min Model Under Norm-2 Type Uncertainty Set in Data-Driven Distributionally Robust Optimization
To accelerate the computational speed of data-driven distributionally robust optimization (DDRO), this letter presents a novel algorithmic approach to solve the inner max-min model under norm-2 type uncertainty set in DDRO. The proposed method can solve the problem in an easily implemented way instead of a time-consuming optimization process using commercial solvers. Comparisons of computational time between the algorithmic approach and optimization solvers verify the effectiveness of the proposed method.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (5) , 4867-4880
Convex Hull Model for a Single-Unit Commitment Problem With Pumped Hydro Storage Unit
The single-unit commitment (1UC) aims at maximizing the payoff within a time series of given electricity prices. 1UC is subject to generation constraints, which is formulated as a mixed-integer programming (MIP) optimization problem. To reduce the computational complexity of PSU-1UC, this paper constructs the convex hull of PSU-1UC. Focusing on the possible combinations of generating and pumping time intervals, we first establish a dynamic program (DP) model which is solved in polynomial time. Second, a set of public variables were defined to describe the coupling relationship between different consecutive time intervals. Then, we reformulate the DP model into a linear programming (LP) model in a higher-dimensional space, which provides the convex hull formulation of PSU-1UC. Finally, we theoretically prove that the optimal solutions of the proposed convex hull model and the original MIP are the same. The exponential time complexity of PSU-1UC is reduced to polynomial time complexity, which will speed up the PSU self-scheduling/bidding problems and the decomposed algorithm for large-scale hydrothermal UC problems. Numerical experiments demonstrate the effectiveness and efficiency of the proposed model for PSU-1UC.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (5) , 4867-4880
Convex Hull Model for a Single-Unit Commitment Problem With Pumped Hydro Storage Unit
The single-unit commitment (1UC) aims at maximizing the payoff within a time series of given electricity prices. 1UC is subject to generation constraints, which is formulated as a mixed-integer programming (MIP) optimization problem. To reduce the computational complexity of PSU-1UC, this paper constructs the convex hull of PSU-1UC. Focusing on the possible combinations of generating and pumping time intervals, we first establish a dynamic program (DP) model which is solved in polynomial time. Second, a set of public variables were defined to describe the coupling relationship between different consecutive time intervals. Then, we reformulate the DP model into a linear programming (LP) model in a higher-dimensional space, which provides the convex hull formulation of PSU-1UC. Finally, we theoretically prove that the optimal solutions of the proposed convex hull model and the original MIP are the same. The exponential time complexity of PSU-1UC is reduced to polynomial time complexity, which will speed up the PSU self-scheduling/bidding problems and the decomposed algorithm for large-scale hydrothermal UC problems. Numerical experiments demonstrate the effectiveness and efficiency of the proposed model for PSU-1UC.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (6) , 4157-4167
Interval Total Transfer Capability for Mesh HVDC Systems Based on Sum of Squares and Multi-Dimensional Holomorphic Embedding Method
Total transfer capability evaluation is an effective method to analyze the backbone transmission capability among regions. To address renewable energy uncertainties, an interval total transfer capability model based on the multi-dimensional holomorphic embedding method and sum of squares relaxation technique is proposed to solve the regional total transfer capability in meshed high voltage direct current systems. First, the multi-dimensional holomorphic embedding method is used to derive the analytical expressions of regional tie lines. Second, the interval total transfer capability model can be reformulated by two bi-level optimization models. Third, sum of squares relaxation is employed to solve the two optimization problems. Numerical results on a 40-bus European Synthetic System and the Chinese meshed high voltage direct current system validate the effectiveness of the proposed model and method.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (6) , 4157-4167
Interval Total Transfer Capability for Mesh HVDC Systems Based on Sum of Squares and Multi-Dimensional Holomorphic Embedding Method
Total transfer capability evaluation is an effective method to analyze the backbone transmission capability among regions. To address renewable energy uncertainties, an interval total transfer capability model based on the multi-dimensional holomorphic embedding method and sum of squares relaxation technique is proposed to solve the regional total transfer capability in meshed high voltage direct current systems. First, the multi-dimensional holomorphic embedding method is used to derive the analytical expressions of regional tie lines. Second, the interval total transfer capability model can be reformulated by two bi-level optimization models. Third, sum of squares relaxation is employed to solve the two optimization problems. Numerical results on a 40-bus European Synthetic System and the Chinese meshed high voltage direct current system validate the effectiveness of the proposed model and method.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 8 (4) , 55-69
Toward a Global Green Smart Microgrid: An Industrial Park in China
Today, the global energy crisis is becoming more serious, which is manifested by the shortage of fossil fuels and considerable environmental pollution. As a supplement to large-scale centralized power generation, distributed energy resources, such as wind and photovoltaic (PV) power, provide a new way to solve the energy crisis.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 8 (4) , 55-69
Toward a Global Green Smart Microgrid: An Industrial Park in China
Today, the global energy crisis is becoming more serious, which is manifested by the shortage of fossil fuels and considerable environmental pollution. As a supplement to large-scale centralized power generation, distributed energy resources, such as wind and photovoltaic (PV) power, provide a new way to solve the energy crisis.
- 12 May 2020
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 142 (6) , 1-22
A Hybrid Ray-Tracing Optical Model for Compound Parabolic Concentrators
Compound parabolic concentrator (CPC), as a hybrid of the stationary and the tracking collectors, can collect both direct beam and diffuse radiation. CPCs are favorable choices for medium-temperature applications for their high thermal efficiency and their cost-effectiveness. Optical models are important tools to predict the solar concentrating capability of the CPC. Despite the numerous, optical models developed in the literature and used for parametric studies of the optical characteristics of CPCs, the angular optical properties of the glass envelope, reflector, and receiver are rarely included. Moreover, most existing optical modeling studies of CPCs did not consider or present the loss associated with the refraction in the glass envelope. This study aims to fill these gaps by developing a comprehensive CPC optical model with the capability of profile generation, hybrid ray-tracing (HRT), surface property simulation, and sky model. The HRT can achieve high accuracy using significantly fewer computation resources compared with Monte Carlo ray-tracing (MCRT) and was validated against tracepro. The new optical model incorporates angular and spectrum dependence of optical properties for refraction and reflection using multilayer thin-film theory. Finally, the proposed HRT model was used to analyze the error associated with neglecting geometric design parameters and angular dependency of optical properties in optical simulation. The results suggest that the gaps between the receiver, glass envelope, and the reflector, the refraction of the glass and angular dependence of transmittance, and absorptance should be included in simulation to avoid considerable errors.
- 12 May 2020
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 142 (6) , 1-22
A Hybrid Ray-Tracing Optical Model for Compound Parabolic Concentrators
Compound parabolic concentrator (CPC), as a hybrid of the stationary and the tracking collectors, can collect both direct beam and diffuse radiation. CPCs are favorable choices for medium-temperature applications for their high thermal efficiency and their cost-effectiveness. Optical models are important tools to predict the solar concentrating capability of the CPC. Despite the numerous, optical models developed in the literature and used for parametric studies of the optical characteristics of CPCs, the angular optical properties of the glass envelope, reflector, and receiver are rarely included. Moreover, most existing optical modeling studies of CPCs did not consider or present the loss associated with the refraction in the glass envelope. This study aims to fill these gaps by developing a comprehensive CPC optical model with the capability of profile generation, hybrid ray-tracing (HRT), surface property simulation, and sky model. The HRT can achieve high accuracy using significantly fewer computation resources compared with Monte Carlo ray-tracing (MCRT) and was validated against tracepro. The new optical model incorporates angular and spectrum dependence of optical properties for refraction and reflection using multilayer thin-film theory. Finally, the proposed HRT model was used to analyze the error associated with neglecting geometric design parameters and angular dependency of optical properties in optical simulation. The results suggest that the gaps between the receiver, glass envelope, and the reflector, the refraction of the glass and angular dependence of transmittance, and absorptance should be included in simulation to avoid considerable errors.
- 1 November 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 162, 114261
Development and case study of the liquid desiccant system module in sorption system simulation program (SorpSim)
- 1 November 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 162, 114261
Development and case study of the liquid desiccant system module in sorption system simulation program (SorpSim)
- 1 January 2010
- Published by ASME International
- p. 225-230
Design and Analysis of an Integrated Solar Absorption Cooling and Heating System at Purdue University
As one of the most promising solutions to the reduction of fossil fuel consumption and greenhouse gas emissions, the use of solar energy for building space heating and cooling recently has again aroused researcher’s interest with the growing awareness of the global warming and other environmental problems. Compared to the relatively mature solar heating, solar cooling technology remains at the demonstration and testing stage due to its complicated system characteristics, both in concept and construction. Among many solar cooling technologies, solar absorption technology is the most suitable technology for the solar cooling. The major barriers to widespread deployment of the solar absorption cooling are its high first cost, the lack of guidelines of its design and operation, and the relative low system performance due to the lack of the system integration. The paper provides detailed information of an on-going solar heating and cooling research project conducted at Purdue University in West Lafayette, Indiana. The aim of the research is to develop a cost-effective and integrated solar heating and cooling system. The solar thermal system primarily includes a 45kW single effect absorption chiller, evacuated tube solar collectors (ET), and heat storage tanks. The system has been designed based upon scientific principles and engineering fundamentals. It has been analyzed and optimized to achieve the high cost-effectiveness and the high system efficiency through the system performance simulation in Transient Energy System Simulation (TRNSYS) program.
- 1 January 2010
- Published by ASME International
- p. 225-230
Design and Analysis of an Integrated Solar Absorption Cooling and Heating System at Purdue University
As one of the most promising solutions to the reduction of fossil fuel consumption and greenhouse gas emissions, the use of solar energy for building space heating and cooling recently has again aroused researcher’s interest with the growing awareness of the global warming and other environmental problems. Compared to the relatively mature solar heating, solar cooling technology remains at the demonstration and testing stage due to its complicated system characteristics, both in concept and construction. Among many solar cooling technologies, solar absorption technology is the most suitable technology for the solar cooling. The major barriers to widespread deployment of the solar absorption cooling are its high first cost, the lack of guidelines of its design and operation, and the relative low system performance due to the lack of the system integration. The paper provides detailed information of an on-going solar heating and cooling research project conducted at Purdue University in West Lafayette, Indiana. The aim of the research is to develop a cost-effective and integrated solar heating and cooling system. The solar thermal system primarily includes a 45kW single effect absorption chiller, evacuated tube solar collectors (ET), and heat storage tanks. The system has been designed based upon scientific principles and engineering fundamentals. It has been analyzed and optimized to achieve the high cost-effectiveness and the high system efficiency through the system performance simulation in Transient Energy System Simulation (TRNSYS) program.