Matias Risaro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matias Risaro has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Cecilia Clivati
Istituto Nazionale di Ricerca Metrologica (INRiM)
7 shared publications - Davide Calonico
Istituto Nazionale di Ricerca Metrologica (INRiM)
7 shared publications - Filippo Levi
Istituto Nazionale di Ricerca Metrologica (INRiM)
7 shared publications - Marco Pizzocaro
Istituto Nazionale di Ricerca Metrologica (INRiM)
7 shared publications - Irene Goti
Istituto Nazionale di Ricerca Metrologica (INRiM)
6 shared publications - Stefano Condio
Istituto Nazionale di Ricerca Metrologica (INRiM)
6 shared publications
Latest Publications
- Open Access
Development of a High-Repetition-Rate Ti:Sa Optical Frequency Comb at INTI for Laser Frequency Traceability and Calibration
We report the development of the first optical frequency comb (OFC) based on an in-house Ti:Sa femtosecond laser in Argentina, implemented at the National Metrology Institute (INTI). The system operates at a 1 GHz repetition rate with a broadband spectrum spanning from 500 to 1100 nm. The carrier-envelope offset frequency and the repetition rate are both phase-locked to a cesium atomic clock, establishing a direct link between the national frequency standard and the optical domain. This development represents a major step forward for national metrology and enables frequency-instability measurements of stable lasers within the country. To demonstrate its capabilities, the performance of a Nd:YAG Mephisto laser at 1064 nm was evaluated by measuring the beat note between its second harmonic and the OFC, allowing a direct assessment of its frequency noise and stability.
Open AccessDevelopment of a High-Repetition-Rate Ti:Sa Optical Frequency Comb at INTI for Laser Frequency Traceability and Calibration
We report the development of the first optical frequency comb (OFC) based on an in-house Ti:Sa femtosecond laser in Argentina, implemented at the National Metrology Institute (INTI). The system operates at a 1 GHz repetition rate with a broadband spectrum spanning from 500 to 1100 nm. The carrier-envelope offset frequency and the repetition rate are both phase-locked to a cesium atomic clock, establishing a direct link between the national frequency standard and the optical domain. This development represents a major step forward for national metrology and enables frequency-instability measurements of stable lasers within the country. To demonstrate its capabilities, the performance of a Nd:YAG Mephisto laser at 1064 nm was evaluated by measuring the beat note between its second harmonic and the OFC, allowing a direct assessment of its frequency noise and stability.
- Open Access
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (3) , 033250
International optical clock comparison using the European optical fiber network
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the 10 − 18 level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from 7.7 × 10 − 18 to 6.1 × 10 − 17 . Among the results, the Yb + 171 ( E 3 ) clocks at NPL and PTB demonstrated agreement within an uncertainty of 7.7 × 10 − 18 , marking the first international verification of two independently developed optical clocks below one part in 10 17 . The operation of the Hg 199 clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with Yb + 171 ( E 3 ) , Yb 171 , and Sr 87 optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (3) , 033250
Open AccessInternational optical clock comparison using the European optical fiber network
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the 10 − 18 level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from 7.7 × 10 − 18 to 6.1 × 10 − 17 . Among the results, the Yb + 171 ( E 3 ) clocks at NPL and PTB demonstrated agreement within an uncertainty of 7.7 × 10 − 18 , marking the first international verification of two independently developed optical clocks below one part in 10 17 . The operation of the Hg 199 clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with Yb + 171 ( E 3 ) , Yb 171 , and Sr 87 optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.
- 24 June 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (7) , 1190
Laser fractional frequency instability at 4 ×10 -17 with a room temperature optical reference cavity
Ultrastable lasers play a key role in optical frequency metrology, setting the measurement speed, and ultimately impacting both the stability and accuracy of optical frequency standards. Here, we demonstrate a laser fractional frequency instability at 4×10 −17 and a laser frequency linewidth of 12 mHz full width at half-maximum, employing a 68 cm long optical reference cavity operating at room temperature. To the best of our knowledge, both the frequency instability and the linewidth are the lowest ever reported for a room temperature system. This work highlights that state-of-the-art frequency stability and spectral purity are achievable at room temperature, making them accessible to a broader range of users.
- 24 June 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (7) , 1190
Laser fractional frequency instability at 4 ×10 -17 with a room temperature optical reference cavity
Ultrastable lasers play a key role in optical frequency metrology, setting the measurement speed, and ultimately impacting both the stability and accuracy of optical frequency standards. Here, we demonstrate a laser fractional frequency instability at 4×10 −17 and a laser frequency linewidth of 12 mHz full width at half-maximum, employing a 68 cm long optical reference cavity operating at room temperature. To the best of our knowledge, both the frequency instability and the linewidth are the lowest ever reported for a room temperature system. This work highlights that state-of-the-art frequency stability and spectral purity are achievable at room temperature, making them accessible to a broader range of users.
- Open Access
- 1 February 2026
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 138 (2) , 024504
A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison
An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K -band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of 10 −15 s s −1 . This pilot study demonstrates that standard high-frequency ( K -band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K / Q / W -band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters.
- 1 February 2026
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 138 (2) , 024504
Open AccessA High-frequency Geodetic VLBI Experiment for Optical Clock Comparison
An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K -band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of 10 −15 s s −1 . This pilot study demonstrates that standard high-frequency ( K -band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K / Q / W -band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters.
- 17 April 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (4) , 523-530
Year-long optical time scale with sub-nanosecond capabilities
An atomic time scale is a method for marking events and the passage of time by using atomic frequency standards. Thanks to the superior performance of atomic clocks based on optical transitions, time scales generated with optical clocks have the potential to be more accurate and stable than those based on microwave clocks. In this work, we demonstrate an experimental optical time scale based on the INRiM Yb optical lattice clock and a hydrogen maser as a flywheel oscillator, showing sub-nanosecond accuracy over months-long periods and nanosecond accuracy over a 1-year period. The obtained results show that optical time scales have competitive performances even when the optical clock has a limited and non-uniformly distributed up-time. Consequently, we are working to include the Yb clock within the ensemble of clocks routinely used for the generation of the Italian time scale. Furthermore, these results represent a crucial step towards the future redefinition of the second of the International System of Units based on an optical transition.
- 17 April 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (4) , 523-530
Year-long optical time scale with sub-nanosecond capabilities
An atomic time scale is a method for marking events and the passage of time by using atomic frequency standards. Thanks to the superior performance of atomic clocks based on optical transitions, time scales generated with optical clocks have the potential to be more accurate and stable than those based on microwave clocks. In this work, we demonstrate an experimental optical time scale based on the INRiM Yb optical lattice clock and a hydrogen maser as a flywheel oscillator, showing sub-nanosecond accuracy over months-long periods and nanosecond accuracy over a 1-year period. The obtained results show that optical time scales have competitive performances even when the optical clock has a limited and non-uniformly distributed up-time. Consequently, we are working to include the Yb clock within the ensemble of clocks routinely used for the generation of the Italian time scale. Furthermore, these results represent a crucial step towards the future redefinition of the second of the International System of Units based on an optical transition.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
IT-Yb1 Optical Lattice Clock: Absolute Frequency Measurement at the Cs Fountain Uncertainty Level
SummaryWe report the result of the new absolute frequency measurement of 171 Yb performed at INRIM. The frequency of our optical lattice clock IT-Yb1 is measured against the local cryogenic Cs fountain IT-CsF2 during a campaign that lasted 14 months. The frequency measurements were performed with two different techniques, i.e. using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for the Cs interrogation from the Yb ultrastable laser with an optical frequency comb. The frequency of the Yb unperturbed clock transition $^1{S_0}{ \to ^3}{P_0}$ is 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7 × 10 –16 , limited by the uncertainty of IT-CsF2. This is the absolute frequency measurement of a Yb clock against a Cs fountain with the lowest uncertainty. The result agrees with the Yb frequency value recommended by the Consultative Committee for Time and Frequency (CCTF). Moreover, the Yb data acquired during this campaign have been submitted to the Bureau of Weights and Measures (BIPM) to contribute to the calibration of the International Atomic Time (TAI). This work confirms the reliability of Yb as a secondary representation of the second.- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
IT-Yb1 Optical Lattice Clock: Absolute Frequency Measurement at the Cs Fountain Uncertainty Level
SummaryWe report the result of the new absolute frequency measurement of 171 Yb performed at INRIM. The frequency of our optical lattice clock IT-Yb1 is measured against the local cryogenic Cs fountain IT-CsF2 during a campaign that lasted 14 months. The frequency measurements were performed with two different techniques, i.e. using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for the Cs interrogation from the Yb ultrastable laser with an optical frequency comb. The frequency of the Yb unperturbed clock transition $^1{S_0}{ \to ^3}{P_0}$ is 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7 × 10 –16 , limited by the uncertainty of IT-CsF2. This is the absolute frequency measurement of a Yb clock against a Cs fountain with the lowest uncertainty. The result agrees with the Yb frequency value recommended by the Consultative Committee for Time and Frequency (CCTF). Moreover, the Yb data acquired during this campaign have been submitted to the Bureau of Weights and Measures (BIPM) to contribute to the calibration of the International Atomic Time (TAI). This work confirms the reliability of Yb as a secondary representation of the second.- Open Access
- 3 May 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (3) , 035002
Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14 months. Measurements are performed by either using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for Cs interrogation using an optical frequency comb. The frequency of the 171Yb unperturbed clock transition 1 S 0 → 3 P0 results to be 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7 × 10 − 16 that is limited by the uncertainty of IT-CsF2. Our measurement is in agreement with the Yb frequency recommended by the Consultative Committee for Time and Frequency. This result confirms the reliability of Yb as a secondary representation of the second and is relevant to the process of redefining the second in the International System of Units on an optical transition.
- 3 May 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (3) , 035002
Open AccessAbsolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14 months. Measurements are performed by either using a hydrogen maser as a transfer oscillator or by synthesizing a low-noise microwave for Cs interrogation using an optical frequency comb. The frequency of the 171Yb unperturbed clock transition 1 S 0 → 3 P0 results to be 518 295 836 590 863.44(14) Hz, with a total fractional uncertainty of 2.7 × 10 − 16 that is limited by the uncertainty of IT-CsF2. Our measurement is in agreement with the Yb frequency recommended by the Consultative Committee for Time and Frequency. This result confirms the reliability of Yb as a secondary representation of the second and is relevant to the process of redefining the second in the International System of Units on an optical transition.
- 31 March 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (7) , 1958-1961
Broadband serrodyne phase modulation for optical frequency standards and spectral purity transfer
We perform low phase noise, efficient serrodyne modulation for optical frequency control and spectral purity transfer between two ultrastable lasers. After characterizing serrodyne modulation efficiency and its bandwidth, we estimate the phase noise induced by the modulation setup by developing a novel, to the best of our knowledge, composite self-heterodyne interferometer. Exploiting serrodyne modulation, we phase locked a 698 nm ultrastable laser to a superior ultrastable laser source at 1156 nm by means of a frequency comb as a transfer oscillator. We show that this technique is a reliable tool for ultrastable optical frequency standards.
- 31 March 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (7) , 1958-1961
Broadband serrodyne phase modulation for optical frequency standards and spectral purity transfer
We perform low phase noise, efficient serrodyne modulation for optical frequency control and spectral purity transfer between two ultrastable lasers. After characterizing serrodyne modulation efficiency and its bandwidth, we estimate the phase noise induced by the modulation setup by developing a novel, to the best of our knowledge, composite self-heterodyne interferometer. Exploiting serrodyne modulation, we phase locked a 698 nm ultrastable laser to a superior ultrastable laser source at 1156 nm by means of a frequency comb as a transfer oscillator. We show that this technique is a reliable tool for ultrastable optical frequency standards.
- Open Access
- 5 December 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 18 (6) , 064010
Improving the Resolution of Comb-Based Frequency Measurements Using a Track-And-Hold Amplifier
The advent of optical frequency standards with ultimate uncertainties in the low requires femtosecond frequency combs to support a similar level of resolution in the spectral transfer and the computation of optical frequency ratios. The related experimental challenges grow together with the number of optical frequencies to be measured simultaneously, as in many cases the comb’s optical power does not allow reliable beatnote counting or tracking in all the spectral regions of interest. Here we describe the use of a track-and-hold amplifier to implement the gated detection, a previously proposed technique for improving the signal-to-noise ratio of the beatnote between a low-power tooth of the frequency comb and a continuous-wave laser. We demonstrate a 12-dB improvement in the signal-to-noise ratio of beatnotes involving a broadband-spanning optical comb as compared to traditional detection schemes. Our approach enables reliable and cycle-slip-free spectral purity transfer and reduces the system sensitivity to power drops in the comb spectrum. Being based on a single chip, it is robust, versatile, and easily embedded in more complex experimental schemes.- 5 December 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 18 (6) , 064010
Open AccessImproving the Resolution of Comb-Based Frequency Measurements Using a Track-And-Hold Amplifier
The advent of optical frequency standards with ultimate uncertainties in the low requires femtosecond frequency combs to support a similar level of resolution in the spectral transfer and the computation of optical frequency ratios. The related experimental challenges grow together with the number of optical frequencies to be measured simultaneously, as in many cases the comb’s optical power does not allow reliable beatnote counting or tracking in all the spectral regions of interest. Here we describe the use of a track-and-hold amplifier to implement the gated detection, a previously proposed technique for improving the signal-to-noise ratio of the beatnote between a low-power tooth of the frequency comb and a continuous-wave laser. We demonstrate a 12-dB improvement in the signal-to-noise ratio of beatnotes involving a broadband-spanning optical comb as compared to traditional detection schemes. Our approach enables reliable and cycle-slip-free spectral purity transfer and reduces the system sensitivity to power drops in the comb spectrum. Being based on a single chip, it is robust, versatile, and easily embedded in more complex experimental schemes. - Open Access
- 3 November 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 18 (5) , 054009
Coherent Optical-Fiber Link Across Italy and France
The dissemination of atomic clocks with fiber-based techniques finds application in the fields of metrology, fundamental physics, navigation, and spectroscopy but is a challenge in terms of reliability, maintenance, and performance. Here, we describe the realization of a 1023-km-long fiber link between the metrological institutes of Italy and France that shares the infrastructure with the Internet traffic and exploits segmentation in shorter, cascaded spans to fight optical losses exceeding 280 dB. With four months of quasicontinuous operation of this link, we compared the , , and atomic clocks at our laboratories, highlighting the potential of this tool to assess the clock uncertainty budgets, characterize advanced satellite techniques, and develop optical timescales. The integration of the metrological, fiber-based infrastructures in the two countries, connecting photonics and spectroscopy laboratories as well as telescope facilities, provides the research community with a physical layer over which applications can be built on.- 3 November 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 18 (5) , 054009
Open AccessCoherent Optical-Fiber Link Across Italy and France
The dissemination of atomic clocks with fiber-based techniques finds application in the fields of metrology, fundamental physics, navigation, and spectroscopy but is a challenge in terms of reliability, maintenance, and performance. Here, we describe the realization of a 1023-km-long fiber link between the metrological institutes of Italy and France that shares the infrastructure with the Internet traffic and exploits segmentation in shorter, cascaded spans to fight optical losses exceeding 280 dB. With four months of quasicontinuous operation of this link, we compared the , , and atomic clocks at our laboratories, highlighting the potential of this tool to assess the clock uncertainty budgets, characterize advanced satellite techniques, and develop optical timescales. The integration of the metrological, fiber-based infrastructures in the two countries, connecting photonics and spectroscopy laboratories as well as telescope facilities, provides the research community with a physical layer over which applications can be built on.