Rosana Tieka Miyazaki Brancucci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rosana Tieka Miyazaki Brancucci has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Georgia Kleinschmitt Westenhofen
Departamento e Instituto de Psiquiatria, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brazil
2 shared publications - Ida Fortini
Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas, Divisão de Neurologia, São Paulo SP, Brazil
2 shared publications - Mario Fernando Prieto Peres
University of São Paulo, São Paulo, São Paulo, Brazil
2 shared publications - Vanda de Lelis
School of Medicine, University of São Paulo. São Paulo, Sao Paulo, Brazil
2 shared publications - Gabriel Taricani Kubota
Pain Center, Department of Neurology, University of São Paulo, São Paulo, Brazil
1 shared publication - Gianluca Coppola
Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Polo Pontino, Latina, Italy
1 shared publication
Latest Publications
- Open Access
- 12 May 2026
- Published by Headache Medicine in Headache Medicine
- Vol. 17 (2) , 98-110
Concordância entre única medida e a média de três medidas do limiar de dor por pressão craniofacial: viabilidade em adultos saudáveis.
BackgroundPressure pain threshold assessment is used to quantify pain sensitivity in headache disorders, reflecting peripheral and central sensitization of the nociceptive system. Traditional protocols involve multiple measurements to ensure reliability, but these protocols are time-consuming and may cause participant fatigue and discomfort. ObjectiveTo evaluate the agreement and reliability between a single Pressure Pain Threshold (PPT) measurement and the mean of three measurements in the craniofacial of individuals without a history of headache disorders, using a digital algometer. MethodsCross-sectional methodological study with ten volunteers (60% female, mean age 43±8 years) without headache history. Pressure pain threshold was assessed at eight craniofacial sites (bilateral: occipital, temporal, masseter; central: frontal, vertex) using a digital algometer. Three consecutive measurements were performed at each site with 10-minute intervals. Reliability between measurements was assessed using Intraclass Correlation Coefficient (ICC), while agreement and systematic bias were evaluated using Bland–Altman analysis. ResultsIntra-rater reliability ranged from moderate to good (ICC=0.54–0.96) across individual sites, with good-to-excellent reliability in bilateral occipital, temporal, and masseter sites (ICC=0.62–0.96). Reliability between the single measurement and the mean of three trials was uniformly excellent (ICC=0.93–0.98) Bland-Altman analysis showed minimal bias (mean differences near zero) and relatively narrow limits of agreement in peripheral sites, with wider limits observed in central regions.ConclusionA single pressure pain threshold measurement demonstrated agreement comparable to the mean of three measurements, supporting the potential use of simplified assessment protocols.
- 12 May 2026
- Published by Headache Medicine in Headache Medicine
- Vol. 17 (2) , 98-110
Open AccessConcordância entre única medida e a média de três medidas do limiar de dor por pressão craniofacial: viabilidade em adultos saudáveis.
BackgroundPressure pain threshold assessment is used to quantify pain sensitivity in headache disorders, reflecting peripheral and central sensitization of the nociceptive system. Traditional protocols involve multiple measurements to ensure reliability, but these protocols are time-consuming and may cause participant fatigue and discomfort. ObjectiveTo evaluate the agreement and reliability between a single Pressure Pain Threshold (PPT) measurement and the mean of three measurements in the craniofacial of individuals without a history of headache disorders, using a digital algometer. MethodsCross-sectional methodological study with ten volunteers (60% female, mean age 43±8 years) without headache history. Pressure pain threshold was assessed at eight craniofacial sites (bilateral: occipital, temporal, masseter; central: frontal, vertex) using a digital algometer. Three consecutive measurements were performed at each site with 10-minute intervals. Reliability between measurements was assessed using Intraclass Correlation Coefficient (ICC), while agreement and systematic bias were evaluated using Bland–Altman analysis. ResultsIntra-rater reliability ranged from moderate to good (ICC=0.54–0.96) across individual sites, with good-to-excellent reliability in bilateral occipital, temporal, and masseter sites (ICC=0.62–0.96). Reliability between the single measurement and the mean of three trials was uniformly excellent (ICC=0.93–0.98) Bland-Altman analysis showed minimal bias (mean differences near zero) and relatively narrow limits of agreement in peripheral sites, with wider limits observed in central regions.ConclusionA single pressure pain threshold measurement demonstrated agreement comparable to the mean of three measurements, supporting the potential use of simplified assessment protocols.
- Open Access
- 27 October 2022
- Published by Headache Medicine in Headache Medicine
- p. 20
Intra-rater reliability of pressure pain threshold using a digital algometer
Background Pressure Pain Thresholds (PPT) has been the main sensory modality studied in headache disorders. It is usually repetitive, leading to potential variability between measurements. Since threshold estimation relies on the observer, patient, body site, and the device used, it is important to assess measurement reliability in the specific clinical and methodological scenario to be studied in order to minimize error. Objective The aim of this study is to confirm intra-rater reliability of PPT in the head of adults using a digital algometer device. Methods PPT was measured with a digital algometer in 3 consecutive assessments conducted 10 min apart. Eight sites were measured in each time at the occipital, temporal and masseter regions bilaterally, frontal and vertex at midline. The reliability using intra-class variability (ICC) and covariance were calculated between times 1, 2, 3, and all times versus the mean. Scores above 0,75 were considered as having excellent reliability. Results Ten healthy volunteers aged (21-55) were studied. The sum of all sites measured in the head was 2182 (+-672) KPa for the first measure, 2085 (+- 626) KPa for the second, 2185 (+-685) for the third, and 2150 (+-685) KPa for the mean. All ICC coefficients calculated were 0,975 or higher in all areas. Conclusions We concluded that one PPT measure in the head with a digital algometer is as reliable as 3 repetitive measures The intra-rater reliability for PPT is considered excellent. Future studies assessing pain vulnerability or predicting headache occurrence can be performed without a significant risk of bias. Keywords: Pressure PainThreshold, Algometry, Reliability, Intra-class.
- 27 October 2022
- Published by Headache Medicine in Headache Medicine
- p. 20
Open AccessIntra-rater reliability of pressure pain threshold using a digital algometer
Background Pressure Pain Thresholds (PPT) has been the main sensory modality studied in headache disorders. It is usually repetitive, leading to potential variability between measurements. Since threshold estimation relies on the observer, patient, body site, and the device used, it is important to assess measurement reliability in the specific clinical and methodological scenario to be studied in order to minimize error. Objective The aim of this study is to confirm intra-rater reliability of PPT in the head of adults using a digital algometer device. Methods PPT was measured with a digital algometer in 3 consecutive assessments conducted 10 min apart. Eight sites were measured in each time at the occipital, temporal and masseter regions bilaterally, frontal and vertex at midline. The reliability using intra-class variability (ICC) and covariance were calculated between times 1, 2, 3, and all times versus the mean. Scores above 0,75 were considered as having excellent reliability. Results Ten healthy volunteers aged (21-55) were studied. The sum of all sites measured in the head was 2182 (+-672) KPa for the first measure, 2085 (+- 626) KPa for the second, 2185 (+-685) for the third, and 2150 (+-685) KPa for the mean. All ICC coefficients calculated were 0,975 or higher in all areas. Conclusions We concluded that one PPT measure in the head with a digital algometer is as reliable as 3 repetitive measures The intra-rater reliability for PPT is considered excellent. Future studies assessing pain vulnerability or predicting headache occurrence can be performed without a significant risk of bias. Keywords: Pressure PainThreshold, Algometry, Reliability, Intra-class.