Zhaoting Ling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhaoting Ling has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Fuming He
Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province Hangzhou China
3 shared publications Siyuan Wang
Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Zhejiang Key Laboratory of Oral Biomedical, Hangzhou, 310000, China; Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, 310000, China; Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, 999077, China
3 shared publications- Walter Yu Hang Lam
Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
3 shared publications Falk Schwendicke
2 shared publications- Kaijing Mao
Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, China
2 shared publications Xiaoting Shen
Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Zhejiang Key Laboratory of Oral Biomedical, Hangzhou, 310000, China; Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, 310000, China
2 shared publications
Latest Publications
- Open Access
- 19 August 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 176
Digital oral health beyond professional dental care settings: A scoping review of technologies and applications from prevention to early detection
- 19 August 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 176
Open AccessDigital oral health beyond professional dental care settings: A scoping review of technologies and applications from prevention to early detection
- 21 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 166, 106516
Clinical evaluation and bone loss prediction of titanium-zirconium implants: A retrospective study of 1-5-year follow-up
- 21 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 166, 106516
Clinical evaluation and bone loss prediction of titanium-zirconium implants: A retrospective study of 1-5-year follow-up
- Open Access
- 29 November 2025
- Published by Elsevier in International Dental Journal
- Vol. 76 (1) , 109296
Digital Dentistry in Clinical Practice: A Scoping Review of Current Capabilities and Future Directions
- 29 November 2025
- Published by Elsevier in International Dental Journal
- Vol. 76 (1) , 109296
Open AccessDigital Dentistry in Clinical Practice: A Scoping Review of Current Capabilities and Future Directions
- Top Cited PapersOpen Access
- 25 January 2025
- Published by Elsevier in International Dental Journal
- Vol. 75 (3) , 1970-1978
External Validation of an AI mHealth Tool for Gingivitis Detection among Older Adults at Daycare Centers: A Pilot Study
- 25 January 2025
- Published by Elsevier in International Dental Journal
- Vol. 75 (3) , 1970-1978
Top Cited PapersOpen AccessExternal Validation of an AI mHealth Tool for Gingivitis Detection among Older Adults at Daycare Centers: A Pilot Study
- 25 April 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (3) , 481-489
Performance of indirect technique in peri‐implant soft tissue contour duplication in the anterior maxilla: A clinical pilot study
ObjectiveTo evaluate the performance of the indirect technique in peri-implant soft tissue contour duplication after the delivery procedure in the anterior maxilla. Materials and MethodsPatients with single implant-supported fixed restorations in the anterior maxilla were recruited. For the impression procedure, an intraoral scan was acquired by both the direct and the indirect techniques. For the delivery procedure, implants were randomly allocated into one of the two groups according to the approaches of digital impression preceding definite crown fabrication (A-direct technique; B-indirect technique) and were scanned again after the definite crown delivery. The stereolithography files were superimposed to analyze changes in peri-implant soft tissue contour after the delivery procedure. The main outcomes were dimensional deviations of peri-implant mucosa, and the secondary outcome was differences in the pink esthetic score (PES). ResultsA total of 20 implants that underwent the complete workflow were included. After the delivery procedure, significant deviations in palatal tissue thickness between the provisional and definite crowns were observed in Group A but these were absent in Group B. Additionally, deviations in labial thickness (0.27 +/- 0.12 mm vs. 0.08 +/- 0.09 mm) and palatal thickness (0.17 +/- 0.15 mm vs. 0.03 +/- 0.08 mm), and labial volume of soft tissue (1.87 +/- 0.94 mm(3) vs. 0.75 +/- 0.74 mm(3)) in Group A were significantly higher than those in Group B. No significant differences in PES were found. ConclusionThe indirect technique of scanning the provisional crown can more accurately duplicate the peri-implant soft tissue contour than the direct technique, resulting in a smaller deviation of the soft tissue in the delivery procedure.
- 25 April 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (3) , 481-489
Performance of indirect technique in peri‐implant soft tissue contour duplication in the anterior maxilla: A clinical pilot study
ObjectiveTo evaluate the performance of the indirect technique in peri-implant soft tissue contour duplication after the delivery procedure in the anterior maxilla. Materials and MethodsPatients with single implant-supported fixed restorations in the anterior maxilla were recruited. For the impression procedure, an intraoral scan was acquired by both the direct and the indirect techniques. For the delivery procedure, implants were randomly allocated into one of the two groups according to the approaches of digital impression preceding definite crown fabrication (A-direct technique; B-indirect technique) and were scanned again after the definite crown delivery. The stereolithography files were superimposed to analyze changes in peri-implant soft tissue contour after the delivery procedure. The main outcomes were dimensional deviations of peri-implant mucosa, and the secondary outcome was differences in the pink esthetic score (PES). ResultsA total of 20 implants that underwent the complete workflow were included. After the delivery procedure, significant deviations in palatal tissue thickness between the provisional and definite crowns were observed in Group A but these were absent in Group B. Additionally, deviations in labial thickness (0.27 +/- 0.12 mm vs. 0.08 +/- 0.09 mm) and palatal thickness (0.17 +/- 0.15 mm vs. 0.03 +/- 0.08 mm), and labial volume of soft tissue (1.87 +/- 0.94 mm(3) vs. 0.75 +/- 0.74 mm(3)) in Group A were significantly higher than those in Group B. No significant differences in PES were found. ConclusionThe indirect technique of scanning the provisional crown can more accurately duplicate the peri-implant soft tissue contour than the direct technique, resulting in a smaller deviation of the soft tissue in the delivery procedure.
- Open Access
- 4 November 2022
- Published by Springer Nature in International Journal of Oral Science
- Vol. 14 (1) , 1-15
The role of dendritic cells in the immunomodulation to implanted biomaterials
Considering the substantial role played by dendritic cells (DCs) in the immune system to bridge innate and adaptive immunity, studies on DC-mediated immunity toward biomaterials principally center on their adjuvant effects in facilitating the adaptive immunity of codelivered antigens. However, the effect of the intrinsic properties of biomaterials on dendritic cells has not been clarified. Recently, researchers have begun to investigate and found that biomaterials that are nonadjuvant could also regulate the immune function of DCs and thus affect subsequent tissue regeneration. In the case of proteins adsorbed onto biomaterial surfaces, their intrinsic properties can direct their orientation and conformation, forming “biomaterial-associated molecular patterns (BAMPs)”. Thus, in this review, we focused on the intrinsic physiochemical properties of biomaterials in the absence of antigens that affect DC immune function and summarized the underlying signaling pathways. Moreover, we preliminarily clarified the specific composition of BAMPs and the interplay between some key molecules and DCs, such as heat shock proteins (HSPs) and high mobility group box 1 (HMGB1). This review provides a new direction for future biomaterial design, through which modulation of host immune responses is applicable to tissue engineering and immunotherapy.
- 4 November 2022
- Published by Springer Nature in International Journal of Oral Science
- Vol. 14 (1) , 1-15
Open AccessThe role of dendritic cells in the immunomodulation to implanted biomaterials
Considering the substantial role played by dendritic cells (DCs) in the immune system to bridge innate and adaptive immunity, studies on DC-mediated immunity toward biomaterials principally center on their adjuvant effects in facilitating the adaptive immunity of codelivered antigens. However, the effect of the intrinsic properties of biomaterials on dendritic cells has not been clarified. Recently, researchers have begun to investigate and found that biomaterials that are nonadjuvant could also regulate the immune function of DCs and thus affect subsequent tissue regeneration. In the case of proteins adsorbed onto biomaterial surfaces, their intrinsic properties can direct their orientation and conformation, forming “biomaterial-associated molecular patterns (BAMPs)”. Thus, in this review, we focused on the intrinsic physiochemical properties of biomaterials in the absence of antigens that affect DC immune function and summarized the underlying signaling pathways. Moreover, we preliminarily clarified the specific composition of BAMPs and the interplay between some key molecules and DCs, such as heat shock proteins (HSPs) and high mobility group box 1 (HMGB1). This review provides a new direction for future biomaterial design, through which modulation of host immune responses is applicable to tissue engineering and immunotherapy.