Toshiaki Sakuyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Toshiaki Sakuyama has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Urai
Toyo University,Dept. of Electrical, Electronic and Communications Engineering,Saitama,Japan
2 shared publications - Hideyuki Kotsuji
Research & Development Group, Hitachi, Ltd., 7-2-1 Omika, Hitachi 319-1221, Japan
2 shared publications Katsuhiko Shiraishi
Hitachi, Ltd, R&D Group, 7-1-1 Oomika-cho, Hitachi-shi, Ibaraki-ken, Japan
2 shared publications- Yasunori Tanaka
Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
2 shared publications Hajime Urai
Hitachi, Ltd., Research & Development Group 7‐2‐1 Omika‐cho, Hitachi‐shi, Ibaraki‐ken 319‐1221 Japan
1 shared publicationHideyuki Kotsuji
Hitachi, Ltd., Research & Development Group 7‐2‐1 Omika‐cho, Hitachi‐shi, Ibaraki‐ken 319‐1221 Japan
1 shared publication
Latest Publications
- 10 July 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (40) , 405503
Comparison of measurement and numerical calculation on spectral profile of ablation arc plasma around current zero in high-voltage gas circuit breakers
A product-scale interrupter with a rated voltage range of 245 kV to 362 kV and current condition of 20 kA root mean square has been examined to study the arc extinguishing process and the appearance of absorption spectrum by C2 molecules immediately before the current zero. The latter has elucidated the presence of C2 molecules outside the arc core, where the temperature is lower. The temporal behaviour of the C2 absorption spectrum and the emission spectrum of the S+ ion have been measured, which have indicated that polytetrafluoroethylene ablation gas is replaced by SF6 because of gas flow from the thermal puffer chamber to the stagnation point. The computed spectra agree well with the experimentally obtained spectra and show similarities to measured profiles. They show evidence of absorption by C2 molecules in the continuous spectrum and the reproduced band heads of the C2 Swan spectrum.
- 10 July 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (40) , 405503
Comparison of measurement and numerical calculation on spectral profile of ablation arc plasma around current zero in high-voltage gas circuit breakers
A product-scale interrupter with a rated voltage range of 245 kV to 362 kV and current condition of 20 kA root mean square has been examined to study the arc extinguishing process and the appearance of absorption spectrum by C2 molecules immediately before the current zero. The latter has elucidated the presence of C2 molecules outside the arc core, where the temperature is lower. The temporal behaviour of the C2 absorption spectrum and the emission spectrum of the S+ ion have been measured, which have indicated that polytetrafluoroethylene ablation gas is replaced by SF6 because of gas flow from the thermal puffer chamber to the stagnation point. The computed spectra agree well with the experimentally obtained spectra and show similarities to measured profiles. They show evidence of absorption by C2 molecules in the continuous spectrum and the reproduced band heads of the C2 Swan spectrum.
- 9 July 2022
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 42 (5) , 1015-1043
Study of Ablation Phenomena of Polymer Bulk Irradiated by Thermal Plasmas Using Induction Thermal Plasma Technique
- 9 July 2022
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 42 (5) , 1015-1043
Study of Ablation Phenomena of Polymer Bulk Irradiated by Thermal Plasmas Using Induction Thermal Plasma Technique
- 10 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3885-3892
Method of Evaluating Dielectric Interruption Capability of High-Voltage Circuit Breaker
Two performance indices using the local dielectric strength are proposed to measure interruption capabilities for breaker terminal fault duties in high-voltage circuit breakers. The dielectric strength at a part in the insulating gas volume between arcing contacts surrounded by an insulating nozzle was evaluated by comparing the applied electric field strength with the critical electric field strength calculated from the gas flow properties. The first index quantifies the effect of suppressing the discharge evolution, which is calculated by integrating the ratio of the critical electric field to the applied electric field in the space between the arcing contacts. The second index expresses the ease of initiating dielectric breakdown, which is calculated by integrating the inverse of the first index in the range of space including the surface of the insulating nozzle. To determine the criteria for the performance indices, gas flow simulations were conducted under experimental conditions with 10-100% of the rated interrupting current. The region excluding failure cases was considered to be the high-performance area.
- 10 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3885-3892
Method of Evaluating Dielectric Interruption Capability of High-Voltage Circuit Breaker
Two performance indices using the local dielectric strength are proposed to measure interruption capabilities for breaker terminal fault duties in high-voltage circuit breakers. The dielectric strength at a part in the insulating gas volume between arcing contacts surrounded by an insulating nozzle was evaluated by comparing the applied electric field strength with the critical electric field strength calculated from the gas flow properties. The first index quantifies the effect of suppressing the discharge evolution, which is calculated by integrating the ratio of the critical electric field to the applied electric field in the space between the arcing contacts. The second index expresses the ease of initiating dielectric breakdown, which is calculated by integrating the inverse of the first index in the range of space including the surface of the insulating nozzle. To determine the criteria for the performance indices, gas flow simulations were conducted under experimental conditions with 10-100% of the rated interrupting current. The region excluding failure cases was considered to be the high-performance area.
- 1 February 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (2) , 215-225
Interrupter Size Effect of High-Voltage Gas Circuit Breaker on Thermal Interruption Performance and Current Zero Properties
- 1 February 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (2) , 215-225
Interrupter Size Effect of High-Voltage Gas Circuit Breaker on Thermal Interruption Performance and Current Zero Properties