Riccardo Sacco
Research Subjects
Riccardo Sacco has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Matthieu Lalevée
CETAPS—UR 3832 Research Center for Sports and Athletic Activities Transformations University of Rouen Mont Saint Aignan Normandy France
8 shared publications - Julien Beldame
ICP-Clinique Blomet, 136 bis Rue Blomet, 75015 Paris, France
5 shared publications - Federico Canavese
Orthopedic and Traumatology Department, IRCCS Istituto Giannina Gaslini, Via Gerolamo Gaslini 5, Genoa, Italy; DISC-Dipartimento di scienze chirurgiche e diagnostiche integrate, University of Genova, Viale Benedetto XV N°6, Genova, Italy
4 shared publications - Marie-Aude Munoz
Centre Médical Achille, 200 Avenue des Prés d’Arènes, 34070 Montpellier, France
4 shared publications - Amine Hamza
Orthopedics and Trauma Department, Rouen-Normandy University Hospital, 37 Boulevard Gambetta, Rouen, 76000, France
2 shared publications - Cesar de Cesar Netto
Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, NC, USA
2 shared publications
Latest Publications
- Open Access
- 12 February 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 61
Patellofemoral vs. total knee arthroplasty for isolated patellofemoral osteoarthritis: evidence-based recommendations from a systematic review with GRADE assessment
Introduction: Isolated patellofemoral osteoarthritis (PFOA) remains a therapeutic challenge, with patellofemoral arthroplasty (PFA) and total knee arthroplasty (TKA) representing the main surgical options for end-stage disease. This systematic review applies the GRADE framework to evaluate comparative outcomes of PFA and TKA, providing evidence-based recommendations. Materials and methods: A PRISMA systematic search of Pubmed, Cochrane Library, and Google Scholar was conducted (2010–2025). RCTs, comparative cohort studies, and registry analyses reporting on PFA versus TKA for isolated PFOA were included. Primary outcomes were validated PROMs and implant survival at 2, 5, and 10 years. Secondary outcomes were complications, patient satisfaction, return to sport, and cost-effectiveness. Risk of bias was assessed with RoB 2 and ROBINS-I, and certainty of evidence using GRADE. Results: Ten studies were included (4 RCTs, 6 cohort studies; approximately 10,000 PFAs comprising registries). Moderate-certainty evidence indicated that PFA provides superior early PROMs, and short-term cost-effectiveness compared with TKA. PROMs converged between groups at mid- to long-term follow-up. Long-term data demonstrated a consistently higher revision risk for PFA with moderate certainty, with registry-based 10-year survival of 85% for PFA vs. 95% for TKA, continuing to worsen for PFA after 10 years. Complication rates were similar or lower after PFA, particularly for systemic medical events. Patient satisfaction and return to sport favored PFA short term but became comparable to TKA at mid-term. Conclusion: In carefully selected patients with isolated PFOA, modern onlay PFA yields faster recovery, superior early function, and short-term cost-effectiveness, supported by moderate-certainty evidence. These advantages are offset by a higher long-term revision risk compared with TKA, highlighting the need to inform patients of this trade-off. TKA remains the reference standard for patients with tibiofemoral disease or instability, supported by high-certainty evidence, and offers durable, predictable long-term outcomes in more heterogeneous patient populations. Level of evidence, II: Systematic GRADE (Grading of Recommendations, Assessment, Development and Evaluation) review of RCTs and observational studies.
- 12 February 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 61
Open AccessPatellofemoral vs. total knee arthroplasty for isolated patellofemoral osteoarthritis: evidence-based recommendations from a systematic review with GRADE assessment
Introduction: Isolated patellofemoral osteoarthritis (PFOA) remains a therapeutic challenge, with patellofemoral arthroplasty (PFA) and total knee arthroplasty (TKA) representing the main surgical options for end-stage disease. This systematic review applies the GRADE framework to evaluate comparative outcomes of PFA and TKA, providing evidence-based recommendations. Materials and methods: A PRISMA systematic search of Pubmed, Cochrane Library, and Google Scholar was conducted (2010–2025). RCTs, comparative cohort studies, and registry analyses reporting on PFA versus TKA for isolated PFOA were included. Primary outcomes were validated PROMs and implant survival at 2, 5, and 10 years. Secondary outcomes were complications, patient satisfaction, return to sport, and cost-effectiveness. Risk of bias was assessed with RoB 2 and ROBINS-I, and certainty of evidence using GRADE. Results: Ten studies were included (4 RCTs, 6 cohort studies; approximately 10,000 PFAs comprising registries). Moderate-certainty evidence indicated that PFA provides superior early PROMs, and short-term cost-effectiveness compared with TKA. PROMs converged between groups at mid- to long-term follow-up. Long-term data demonstrated a consistently higher revision risk for PFA with moderate certainty, with registry-based 10-year survival of 85% for PFA vs. 95% for TKA, continuing to worsen for PFA after 10 years. Complication rates were similar or lower after PFA, particularly for systemic medical events. Patient satisfaction and return to sport favored PFA short term but became comparable to TKA at mid-term. Conclusion: In carefully selected patients with isolated PFOA, modern onlay PFA yields faster recovery, superior early function, and short-term cost-effectiveness, supported by moderate-certainty evidence. These advantages are offset by a higher long-term revision risk compared with TKA, highlighting the need to inform patients of this trade-off. TKA remains the reference standard for patients with tibiofemoral disease or instability, supported by high-certainty evidence, and offers durable, predictable long-term outcomes in more heterogeneous patient populations. Level of evidence, II: Systematic GRADE (Grading of Recommendations, Assessment, Development and Evaluation) review of RCTs and observational studies.
- 21 November 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 47 (1) , 103-110
Assessing the Efficacy of a Prefabricated Inflatable Ankle Orthotic Brace in Correcting Progressive Collapsing Foot Deformity With Weightbearing Computed Tomography: A Prospective Case Control Study
Background: We aimed to evaluate the efficacy of a prefabricated inflatable ankle orthotic brace (IAOB) to improve the 3-dimensional (3D) foot alignment of patients with progressive collapsing foot deformity (PCFD) using weightbearing computed tomography (WBCT). Methods: We prospectively enrolled a consecutive series of symptomatic PCFD patients and a healthy control group matched for mean age, sex, and BMI. The primary endpoint was the paired change in FAO (%) with brace vs no brace. Each PCFD foot underwent 2 WBCT scans with and without an IAOB. The foot 3D alignment was assessed using the foot and ankle offset (FAO) under the assumption that IAOBs could improve at least 50% of the surgical FAO correction (−4.25%). Dedicated 3D measurements allowed the assessment of PCFD classes (from A to D). Results: Both PCFD and control groups included 24 feet. Overall, 48 feet underwent 72 WBCT (24 unbraced PCFD, 24 braced PCFD and 24 controls). Median age was 55.5 years (IQR 26.3) in the PCFD group and 51.0 years (IQR 32.2) in the control group ( P = .58), with a median BMI of 33.5 (IQR 13.4) and 25.4 (IQR 8.3), respectively ( P = .24). Females comprised 58.3% of the control group and 54.2% of the PCFD group ( P = .99). The FAO in the unbraced (6.6 ± 3.7) and braced (5.5 ± 4.2) PCFD group was not significantly improved ( P = .1). After bracing, only class C PCFD showed significant improvement of the forefoot arch angle ( P = .001) and talus–first metatarsal angle ( P = .002). The other PCFD classes were not improved by the brace (class A P = .66, class B P = .44, class D P = .17). Conclusion: These findings suggest device-specific efficacy was limited to class C PCFD on static WBCT measures; clinical benefit remains unproven and warrants PROMs/MCID-anchored studies.
- 21 November 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 47 (1) , 103-110
Assessing the Efficacy of a Prefabricated Inflatable Ankle Orthotic Brace in Correcting Progressive Collapsing Foot Deformity With Weightbearing Computed Tomography: A Prospective Case Control Study
Background: We aimed to evaluate the efficacy of a prefabricated inflatable ankle orthotic brace (IAOB) to improve the 3-dimensional (3D) foot alignment of patients with progressive collapsing foot deformity (PCFD) using weightbearing computed tomography (WBCT). Methods: We prospectively enrolled a consecutive series of symptomatic PCFD patients and a healthy control group matched for mean age, sex, and BMI. The primary endpoint was the paired change in FAO (%) with brace vs no brace. Each PCFD foot underwent 2 WBCT scans with and without an IAOB. The foot 3D alignment was assessed using the foot and ankle offset (FAO) under the assumption that IAOBs could improve at least 50% of the surgical FAO correction (−4.25%). Dedicated 3D measurements allowed the assessment of PCFD classes (from A to D). Results: Both PCFD and control groups included 24 feet. Overall, 48 feet underwent 72 WBCT (24 unbraced PCFD, 24 braced PCFD and 24 controls). Median age was 55.5 years (IQR 26.3) in the PCFD group and 51.0 years (IQR 32.2) in the control group ( P = .58), with a median BMI of 33.5 (IQR 13.4) and 25.4 (IQR 8.3), respectively ( P = .24). Females comprised 58.3% of the control group and 54.2% of the PCFD group ( P = .99). The FAO in the unbraced (6.6 ± 3.7) and braced (5.5 ± 4.2) PCFD group was not significantly improved ( P = .1). After bracing, only class C PCFD showed significant improvement of the forefoot arch angle ( P = .001) and talus–first metatarsal angle ( P = .002). The other PCFD classes were not improved by the brace (class A P = .66, class B P = .44, class D P = .17). Conclusion: These findings suggest device-specific efficacy was limited to class C PCFD on static WBCT measures; clinical benefit remains unproven and warrants PROMs/MCID-anchored studies.
- Open Access
- 1 October 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4)
Robotic vs. conventional total knee arthroplasty over two decades: Evolving trends toward personalised alignment without significant clinical superiority in predominantly mild varus deformity—A systematic review of RCTs
Purpose: Randomised controlled trials (RCTs) comparing robotic‐assisted (RA‐TKA) and conventional total knee arthroplasty (C‐TKA) have demonstrated evolving trends in alignment strategies, surgical workflows and outcomes measurements. This review synthesises current evidence to clarify the evolving role of RA‐TKA over the past two decades. Methods: A PRISMA systematic review was conducted searching PubMed, Cochrane Library, and Google Scholar (2000–2024). Eligible studies were Level I RCTs comparing RA‐TKA to C‐TKA with well‐defined alignment strategies and surgical workflows. Data included demographics, robotic and prosthetic systems, learning curves, outcome measures and complications. Results: From 850 records, 9 RCTs were included (627 TKAs: 317 RA‐TKA, 310 C‐TKA). Patients averaged 66.9 years, BMI 28.1 kg/m², 27.9% male, 69.7 knees, follow‐up 23.7 months. Coronal deformity was predominantly varus (p < 0.05) versus C‐TKA regardless of the alignment strategy, with no significant difference in functional scores (WOMAC, HSS, KSS, OKS and FJS), range of motion or complications. Recent trials increasingly assessed inflammatory markers, periarticular tissue injury, and quality‐of‐life outcomes. Conclusions: Over the past two decades, RA‐TKA has evolved substantially, transitioning from purely bone‐cutting technology to decision‐making platforms enabling alignment personalisation and dynamic soft‐tissue assessment, improving surgical precision regardless of alignment strategy. Clinical superiority over C‐TKA remains inconclusive in relatively low‐risk patients, predominantly older females with varus deformity, highlighting the need for studies with more diverse populations, prosthetic design, long‐term follow‐up, patient‐specific outcomes, standardised workflow and learning curve reporting, and patellofemoral space optimisation. Level of Evidence: Level I, systematic review of non‐homogeneous RCTs.
- 1 October 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4)
Open AccessRobotic vs. conventional total knee arthroplasty over two decades: Evolving trends toward personalised alignment without significant clinical superiority in predominantly mild varus deformity—A systematic review of RCTs
Purpose: Randomised controlled trials (RCTs) comparing robotic‐assisted (RA‐TKA) and conventional total knee arthroplasty (C‐TKA) have demonstrated evolving trends in alignment strategies, surgical workflows and outcomes measurements. This review synthesises current evidence to clarify the evolving role of RA‐TKA over the past two decades. Methods: A PRISMA systematic review was conducted searching PubMed, Cochrane Library, and Google Scholar (2000–2024). Eligible studies were Level I RCTs comparing RA‐TKA to C‐TKA with well‐defined alignment strategies and surgical workflows. Data included demographics, robotic and prosthetic systems, learning curves, outcome measures and complications. Results: From 850 records, 9 RCTs were included (627 TKAs: 317 RA‐TKA, 310 C‐TKA). Patients averaged 66.9 years, BMI 28.1 kg/m², 27.9% male, 69.7 knees, follow‐up 23.7 months. Coronal deformity was predominantly varus (p < 0.05) versus C‐TKA regardless of the alignment strategy, with no significant difference in functional scores (WOMAC, HSS, KSS, OKS and FJS), range of motion or complications. Recent trials increasingly assessed inflammatory markers, periarticular tissue injury, and quality‐of‐life outcomes. Conclusions: Over the past two decades, RA‐TKA has evolved substantially, transitioning from purely bone‐cutting technology to decision‐making platforms enabling alignment personalisation and dynamic soft‐tissue assessment, improving surgical precision regardless of alignment strategy. Clinical superiority over C‐TKA remains inconclusive in relatively low‐risk patients, predominantly older females with varus deformity, highlighting the need for studies with more diverse populations, prosthetic design, long‐term follow‐up, patient‐specific outcomes, standardised workflow and learning curve reporting, and patellofemoral space optimisation. Level of Evidence: Level I, systematic review of non‐homogeneous RCTs.
- Open Access
- 27 June 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (7) , 1438
Spontaneous Reduction in the Intermetatarsal Angle in Distal First Metatarsal Osteotomies with No Lateral Head Displacement in Hallux Valgus
Background: The outcomes of first metatarsal (M1) distal osteotomies in hallux valgus (HV) can be improved, especially for intermetatarsal angle (IMA) correction, which is mainly based on lateral displacement of the M1 head (i.e., translation) through the osteotomy. Conversely, there is a spontaneous reduction in the IMA in first metatarsophalangeal joint (MTP1) arthrodesis. But we do not know whether this can be applied to distal osteotomies. We propose a distal osteotomy, called 3D chevron, which combines supination and varization of the M1 head. This might realign soft tissues around the MTP1, potentially leading to a spontaneous reduction in the IMA by an analogous mechanism to MTP1 fusion. Therefore, our study aimed to assess whether spontaneous reductions in IMAs exist in distal M1 osteotomies in the absence of lateral translations of M1 heads. Methods: A prospective continuous series of 25 3D chevrons was performed. Two groups were formed during surgery. Patients requiring no M1 head lateral displacement were included in the “successful correction without translation” group, and patients requiring M1 head lateral displacement were included in the “failed correction without translation” group. Radiographic analysis was performed preoperatively and at 1 year postoperatively. Results: Twenty-two women and three men, with a mean age of 44.8 ± 14.2 years and a mean body mass index of 22.6 ± 4.1 kg/m2, underwent follow-up at one year after surgery. The “successful correction without translation” group was composed of HV with milder deformities (13/25 HVs, median preoperative IMA = 13 (IQR 2)) compared to the “failed correction without translation” group (median IMA = 16 (IQR 2.25) p < 0.001). Spontaneous reductions in IMAs were observed in the “successful correction without translation” group, with a median decrease in the IMA of 6 degrees (CI95%[5.5; 8.0]; p < 0.001) between preoperative and 1-year radiographs. Conclusion: Distal osteotomies allow for spontaneous reduction in the IMA in HV. First metatarsal head translation through an osteotomy should not be considered as the only procedure to correct IMAs in distal osteotomies.
- 27 June 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (7) , 1438
Open AccessSpontaneous Reduction in the Intermetatarsal Angle in Distal First Metatarsal Osteotomies with No Lateral Head Displacement in Hallux Valgus
Background: The outcomes of first metatarsal (M1) distal osteotomies in hallux valgus (HV) can be improved, especially for intermetatarsal angle (IMA) correction, which is mainly based on lateral displacement of the M1 head (i.e., translation) through the osteotomy. Conversely, there is a spontaneous reduction in the IMA in first metatarsophalangeal joint (MTP1) arthrodesis. But we do not know whether this can be applied to distal osteotomies. We propose a distal osteotomy, called 3D chevron, which combines supination and varization of the M1 head. This might realign soft tissues around the MTP1, potentially leading to a spontaneous reduction in the IMA by an analogous mechanism to MTP1 fusion. Therefore, our study aimed to assess whether spontaneous reductions in IMAs exist in distal M1 osteotomies in the absence of lateral translations of M1 heads. Methods: A prospective continuous series of 25 3D chevrons was performed. Two groups were formed during surgery. Patients requiring no M1 head lateral displacement were included in the “successful correction without translation” group, and patients requiring M1 head lateral displacement were included in the “failed correction without translation” group. Radiographic analysis was performed preoperatively and at 1 year postoperatively. Results: Twenty-two women and three men, with a mean age of 44.8 ± 14.2 years and a mean body mass index of 22.6 ± 4.1 kg/m2, underwent follow-up at one year after surgery. The “successful correction without translation” group was composed of HV with milder deformities (13/25 HVs, median preoperative IMA = 13 (IQR 2)) compared to the “failed correction without translation” group (median IMA = 16 (IQR 2.25) p < 0.001). Spontaneous reductions in IMAs were observed in the “successful correction without translation” group, with a median decrease in the IMA of 6 degrees (CI95%[5.5; 8.0]; p < 0.001) between preoperative and 1-year radiographs. Conclusion: Distal osteotomies allow for spontaneous reduction in the IMA in HV. First metatarsal head translation through an osteotomy should not be considered as the only procedure to correct IMAs in distal osteotomies.
- 22 November 2023
- Published by Springer Nature in European Spine Journal
- Vol. 33 (7) , 2846-2853
Uninstrumented fusion in cervical kyphosis due to neurofibromatosis type I: report of two paediatric cases
Purpose Severe cervical kyphosis (CK) in neurofibromatosis type 1 (NF-1) is associated with a high risk for progression and neurologic impairment in children. We present our surgical technique and mid-term outcomes of uninstrumented anterior tibial strut grafting for severe CK secondary to NF-1. Methods Case report. The Consensus-based Clinical Case Reporting Guideline Development (CARE) guidelines were followed. Results Two paediatric patients (8- and 3-year-old) presented with severe CK secondary to NF-1. A halo body jacket (HV) allowed the progressive distraction of the cervical spine, avoiding neurological compromise and deformity progression. Circumferential fusion was obtained with anterior tibial strut autograft and posterior onlay bone graft. Cervical spine fusion was successfully maintained at a minimum 4-year follow-up in both patients. Conclusion In children with severe CK secondary to NF-1, cervical distraction and immobilisation with a HV followed by uninstrumented anterior tibial strut grafting and posterior bone grafting, provided spinal fusion and stability without increasing the risk of neurological injury and donor site morbidity. The reported surgical technique appears to be a valuable tool in the armamentarium of the spinal surgeon.
- 22 November 2023
- Published by Springer Nature in European Spine Journal
- Vol. 33 (7) , 2846-2853
Uninstrumented fusion in cervical kyphosis due to neurofibromatosis type I: report of two paediatric cases
Purpose Severe cervical kyphosis (CK) in neurofibromatosis type 1 (NF-1) is associated with a high risk for progression and neurologic impairment in children. We present our surgical technique and mid-term outcomes of uninstrumented anterior tibial strut grafting for severe CK secondary to NF-1. Methods Case report. The Consensus-based Clinical Case Reporting Guideline Development (CARE) guidelines were followed. Results Two paediatric patients (8- and 3-year-old) presented with severe CK secondary to NF-1. A halo body jacket (HV) allowed the progressive distraction of the cervical spine, avoiding neurological compromise and deformity progression. Circumferential fusion was obtained with anterior tibial strut autograft and posterior onlay bone graft. Cervical spine fusion was successfully maintained at a minimum 4-year follow-up in both patients. Conclusion In children with severe CK secondary to NF-1, cervical distraction and immobilisation with a HV followed by uninstrumented anterior tibial strut grafting and posterior bone grafting, provided spinal fusion and stability without increasing the risk of neurological injury and donor site morbidity. The reported surgical technique appears to be a valuable tool in the armamentarium of the spinal surgeon.
- Open Access
- 19 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12494
Stretching and Eccentric Exercises Normalize Gait Parameters in Gastrocnemius Tightness Subjects
Background: Isolated gastrocnemius tightness (IGT) is a prevalent condition linked to various foot pathologies. In a previous quantitative gait analysis study, we identified an increase in knee flexion during the midstance phase in IGT patients compared with controls. Although stretching and eccentric exercises (the Stanish protocol) are commonly used for IGT management, their impact on gait parameters remains poorly understood. This study aimed to assess the influence of a Stanish protocol on gait parameters in bilateral IGT subjects. Methods: We enrolled 10 asymptomatic bilateral IGT subjects and 10 controls. Quantitative gait analysis and dynamic baropodometry were carried out on each subject. A Stanish protocol was applied for 4 weeks (five sessions/week) by the IGT group, followed by a similar gait analysis. The ankle and knee range of motion and foot pressure distribution were assessed during the midstance phase of the gait. Results: An increase in knee flexion was initially present in the IGT group compared with controls (8.9 +/− 4.6 vs. 3.4 +/− 2.3 degrees, p < 0.001). There was no difference in the ankle range of motion and foot pressures between the groups at that time. Significant reductions in knee flexion during gait were observed in the IGT subjects after the Stanish protocol (8.9 +/− 4.6 to 3.7 +/− 2.3 degrees, p < 0.001) with a normalization of this parameter (3.4 +/− 2.3 in controls vs. 3.7 +/− 2.3 degrees in IGT, p = 0.72). There was no change in ankle range of motion and foot pressure after the Stanish protocol. Conclusions: Our findings support the effectiveness of the Stanish protocol in reducing knee flexion and normalizing gait in IGT subjects. This protocol not only offers a noninvasive approach for IGT-related issues management but could also enable prophylactic care in asymptomatic cases.
- 19 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12494
Open AccessStretching and Eccentric Exercises Normalize Gait Parameters in Gastrocnemius Tightness Subjects
Background: Isolated gastrocnemius tightness (IGT) is a prevalent condition linked to various foot pathologies. In a previous quantitative gait analysis study, we identified an increase in knee flexion during the midstance phase in IGT patients compared with controls. Although stretching and eccentric exercises (the Stanish protocol) are commonly used for IGT management, their impact on gait parameters remains poorly understood. This study aimed to assess the influence of a Stanish protocol on gait parameters in bilateral IGT subjects. Methods: We enrolled 10 asymptomatic bilateral IGT subjects and 10 controls. Quantitative gait analysis and dynamic baropodometry were carried out on each subject. A Stanish protocol was applied for 4 weeks (five sessions/week) by the IGT group, followed by a similar gait analysis. The ankle and knee range of motion and foot pressure distribution were assessed during the midstance phase of the gait. Results: An increase in knee flexion was initially present in the IGT group compared with controls (8.9 +/− 4.6 vs. 3.4 +/− 2.3 degrees, p < 0.001). There was no difference in the ankle range of motion and foot pressures between the groups at that time. Significant reductions in knee flexion during gait were observed in the IGT subjects after the Stanish protocol (8.9 +/− 4.6 to 3.7 +/− 2.3 degrees, p < 0.001) with a normalization of this parameter (3.4 +/− 2.3 in controls vs. 3.7 +/− 2.3 degrees in IGT, p = 0.72). There was no change in ankle range of motion and foot pressure after the Stanish protocol. Conclusions: Our findings support the effectiveness of the Stanish protocol in reducing knee flexion and normalizing gait in IGT subjects. This protocol not only offers a noninvasive approach for IGT-related issues management but could also enable prophylactic care in asymptomatic cases.
- Open Access
- 16 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (8) , 968
Validation of an Automated Optical Scanner for a Comprehensive Anthropometric Analysis of the Foot and Ankle
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with a 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/− 9.54 years, range 9–75 years), the average variance was 1.4 ± 2 (range 0.1 to 8). Overall, the mean absolute measurement error was <1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance <2.5, with variance percentages <1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusions: The UPOD-S Full-Foot optical Scanner achieved a good reproducibility in a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.
- 16 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (8) , 968
Open AccessValidation of an Automated Optical Scanner for a Comprehensive Anthropometric Analysis of the Foot and Ankle
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with a 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/− 9.54 years, range 9–75 years), the average variance was 1.4 ± 2 (range 0.1 to 8). Overall, the mean absolute measurement error was <1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance <2.5, with variance percentages <1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusions: The UPOD-S Full-Foot optical Scanner achieved a good reproducibility in a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.
- Open Access
- 12 July 2023
- Published by MDPI AG in Preprints.org
Validation of an Automated Optical Scanner for a Comprehensive Anthropometric Analysis of the Foot and Ankle
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/- 9.54 years, range 9-75 years), the average variance was 1.4 ± 2 (range 0,1 to 8). Overall, the mean absolute measurement error was < 1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance < 2.5, with variance percentages < 1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusion: This optical scanner achieved a good reproducibility of a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.
- 12 July 2023
- Published by MDPI AG in Preprints.org
Open AccessValidation of an Automated Optical Scanner for a Comprehensive Anthropometric Analysis of the Foot and Ankle
Background: Our objective was to conduct a comprehensive analysis of the reproducibility of foot and ankle anthropometric measurements with a three-dimensional (3D) optical scanner. Methods: We evaluated thirty-nine different anthropometric parameters obtained with 3D Laser UPOD-S Full-Foot Scanner in a healthy population of twenty subjects. We determined the variance of the measurements for each foot/ankle, and the average variance among different subjects. Results: For 40 feet and ankles (15 women and 5 men; mean age 35.62 +/- 9.54 years, range 9-75 years), the average variance was 1.4 ± 2 (range 0,1 to 8). Overall, the mean absolute measurement error was < 1 mm, with a maximum variance percentage of 8.3%. Forefoot and midfoot circumferences had a low variance < 2.5, with variance percentages < 1%. Hindfoot circumferences, malleolar heights, and the length of the first and fifth metatarsal to the ground contact points showed the highest variance (range 1 to 7). Conclusion: This optical scanner achieved a good reproducibility of a large set of foot and ankle anthropometric measurements. It is a valuable tool for clinical and research purposes.
- Open Access
- 3 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (5) , 549
Assessment of the Efficiency of Measuring Foot and Ankle Edema with a 3D Portable Scanner
Background: To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle and to compare the acquisition time associated with these two methods. Methods: Foot volume was measured in 29 healthy volunteers (58 feet, 24 females and 5 males) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner®) and by water displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. The Kolmogorov-Smirnov test, Lin’s Concordance Correlation Coefficient, and a Student’s t-test were performed. Results: Mean foot volume was 869.7 +/− 165.1 cm3 (3D scanner) versus 867.9 +/− 155.4 cm3 (water-displacement volumetry) (p < 10−5). The concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm3 lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = −0.03 +/− 35.1 cm3). The mean examination time was 4.2 +/− 1.7 min (3D optical scanner) versus 11.1 +/− 2.9 min (water volumeter) (p < 10−4). Conclusions: Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast and can be used in clinical practice and research.
- 3 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (5) , 549
Open AccessAssessment of the Efficiency of Measuring Foot and Ankle Edema with a 3D Portable Scanner
Background: To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle and to compare the acquisition time associated with these two methods. Methods: Foot volume was measured in 29 healthy volunteers (58 feet, 24 females and 5 males) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner®) and by water displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. The Kolmogorov-Smirnov test, Lin’s Concordance Correlation Coefficient, and a Student’s t-test were performed. Results: Mean foot volume was 869.7 +/− 165.1 cm3 (3D scanner) versus 867.9 +/− 155.4 cm3 (water-displacement volumetry) (p < 10−5). The concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm3 lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = −0.03 +/− 35.1 cm3). The mean examination time was 4.2 +/− 1.7 min (3D optical scanner) versus 11.1 +/− 2.9 min (water volumeter) (p < 10−4). Conclusions: Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast and can be used in clinical practice and research.
- Open Access
- 7 April 2023
- Published by MDPI AG in Preprints.org
Assessment of Foot and Ankle Edema With a 3D Portable Scanner
Background. To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle, and to compare the acquisition time associated with these two methods. Methods. Foot volume was measured in 29 healthy volunteers (58 feet, 24 female/5 male) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner ®) and by water-displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. Kolmogorov-Smirnov test, Lin's Concordance Correlation Coefficient, and a Student’s t-test were performed. Results: Mean foot volume was 869.7+/-165.1cm3 (3D scanner) versus 867.9+/-155.4cm3 (water-displacement volumetry) (p <10-5). Concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm3 lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = -0.03 +/- 35.1 cm3). Mean examination time was 4.2 +/-1.7 min (3D optical scanner) versus 11.1 +/-2.9 min (water volumeter) (p<10-4). Conclusion: Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast, and can be used in clinical practice and research.
- 7 April 2023
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Foot and Ankle Edema With a 3D Portable Scanner
Background. To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle, and to compare the acquisition time associated with these two methods. Methods. Foot volume was measured in 29 healthy volunteers (58 feet, 24 female/5 male) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner ®) and by water-displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. Kolmogorov-Smirnov test, Lin's Concordance Correlation Coefficient, and a Student’s t-test were performed. Results: Mean foot volume was 869.7+/-165.1cm3 (3D scanner) versus 867.9+/-155.4cm3 (water-displacement volumetry) (p <10-5). Concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm3 lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = -0.03 +/- 35.1 cm3). Mean examination time was 4.2 +/-1.7 min (3D optical scanner) versus 11.1 +/-2.9 min (water volumeter) (p<10-4). Conclusion: Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast, and can be used in clinical practice and research.