AKAndrzej Krol

Andrzej Krol

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrzej Krol has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Determination of the point-of-first-interaction for an ultra-high-performance brain PET system with onion ring geometry

    by Wei Zheng, Ross Schmidtlein, Eric S. Harmon, Michael O. Thompson, Andrzej Krol

    We used the Monte Carlo GATE v9, (GEANT4) simulations to model annihilation photons interactions in our novel advanced brain-PET scanner in onion-ring geometry (US Patent 20210223414) with monolithic thin LYSO slab optically coupled to SiPM arrays to assess potential improvement of point-of-first-interaction (PFI) localization determination vs. conventional system. Three 250-mm-long cylindrical systems were evaluated: (i) 3–3-3 mm slab thicknesses concentric rings; (ii) 3–3-18 mm slab thicknesses concentric rings with 7-mm air-gaps and inner diameters of 250, 270 and 290 mm, respectively; and (iii) single-ring 24-mm-thick system with 250 mm inner diameter. The brain was simulated by a sphere of radioactive (F-18) water with 170-mm diameter confined by 8-mm thick spherical bone shell. The coincidence events studied via simulations involved photo-electric absorption (PA) and first-order Compton scatter (CS) interactions happening within predefined coincidence-time-window. If the distance between CS and PA event was shorter than the detector intrinsic spatial resolution, we considered it “pseudo single” event at energy-based averaged location (Pavg). We found that for the pseudo single events with energy deposited around 511 keV the median PFI-Pavg distance projected onto the detector plane was 0.5 mm for 3-mm ring, 0.9 mm for 18-mm ring, and 1.0 mm for 24-mm ring. We established that 3–3-3-mm system allowed obtaining more accurate depth-of-interaction (DOI) information with the mean true DOI for PFI of 1.4 mm and absolute uncertainty of 0.3 mm, as compared to the conventional 24-mm-thick single-ring system with the mean true DOI for PFI of 7.5 mm and with higher absolute uncertainty of 1.6 mm. The ratios of the number of intra-ring to inter-ring first-order Compton scattering events were lowest for the central rings (1.9 and 1.3 for 3–3-3-mm and 3–3-18-mm systems, respectively), higher for the distal and proximal rings, and strongly dependent on the ring thickness. The relative probability for forward vs. backward scattering was in the range of 60% to 89%, and 61% to 94% for 3–3-3-mm and 3–3-18-mm systems, respectively. We conclude that the spatial resolution provided by multi-ring geometries may offer substantial improvement when compared to conventional PET system designs with comparable sensitivity.

  • Open Access

    A Fast Convergent Ordered-Subsets Algorithm with Subiteration-Dependent Preconditioners for PET Image Reconstruction

    by Jianfeng Guo, C. Ross Schmidtlein, Andrzej Krol, Si Li, Yizun Lin, Sangtae Ahn, Charles Stearns, Yuesheng Xu

    We investigated the imaging performance of a fast convergent ordered-subsets algorithm with subiteration-dependent preconditioners (SDPs) for positron emission tomography (PET) image reconstruction. In particular, we considered the use of SDP with the block sequential regularized expectation maximization (BSREM) approach with the relative difference prior (RDP) regularizer due to its prior clinical adaptation by vendors. Because the RDP regularization promotes smoothness in the reconstructed image, the directions of the gradients in smooth areas more accurately point toward the objective function's minimizer than those in variable areas. Motivated by this observation, two SDPs have been designed to increase iteration step-sizes in the smooth areas and reduce iteration step-sizes in the variable areas relative to a conventional expectation maximization preconditioner. The momentum technique used for convergence acceleration can be viewed as a special case of SDP. We have proved the global convergence of SDP-BSREM algorithms by assuming certain characteristics of the preconditioner. By means of numerical experiments using both simulated and clinical PET data, we have shown that the SDP-BSREM algorithms substantially improve the convergence rate, as compared to conventional BSREM and a vendor's implementation as Q.Clear. Specifically, SDP-BSREM algorithms converge 35\%-50\% faster in reaching the same objective function value than conventional BSREM and commercial Q.Clear algorithms. Moreover, we showed in phantoms with hot, cold and background regions that the SDP-BSREM algorithms approached the values of a highly converged reference image faster than conventional BSREM and commercial Q.Clear algorithms.

  • Preconditioned alternating projection algorithm for solving the penalized-likelihood SPECT reconstruction problem

    by Si Li, Jiahan Zhang, Andrzej Krol, C. Ross Schmidtlein, David Feiglin, Yuesheng Xu


  • Semi-dynamic preconditioned alternating projection MAP ECT reconstruction from low-dose ECT

    by Andrzej Krol, Si Li, Yuesheng Xu, Jiahan Zhang, Levon O. Vogelsang, Lixin Shen, David H. Feiglin

    The objective of this study was to develop very low noise and high-contrast-to-noise ratio fast proximity algorithm for MAP ECT reconstruction that would allow significant (factor of two or more) patient’s dose reduction, as compared to conventional OSEM algorithm. We proposed a semi-dynamic Preconditioned Alternating Projection Algorithm (PAPA) for solving the maximum a posteriori (MAP) emission computed tomography (ECT) reconstruction problem. Specifically, we formulated the reconstruction problem as a constrained convex optimization problem with the total variation (TV) regularization. We characterized the solution of the constrained convex optimization problem and showed that it satisfies a system of fixed-point equations defined in terms of two proximity operators arising from the convex functions that define the TV-norm and the constrain involved in the problem. We proved theoretically the convergence of the proposed algorithm. For efficient numerical computation, we introduced to the alternating projection algorithm a preconditioning matrix: the EM-preconditioner. In numerical experiments using Monte Carlo simulated SPECT data performance of our algorithms was compared with performance of the conventional EM algorithm with Gaussian postfilter. Based on the results of these experiments, we observed that PAPA algorithm with the EM-preconditioner outperforms very significantly the benchmark EM in terms of contrast-to-noise ratio and the noise characteristics of the reconstructed images.

  • Preconditioned alternating projection algorithms for maximum a posteriori ECT reconstruction

    by Andrzej Krol, Si Li, Lixin Shen, Yuesheng Xu

    We propose a preconditioned alternating projection algorithm (PAPA) for solving the maximum a posteriori (MAP) emission computed tomography (ECT) reconstruction problem. Specifically, we formulate the reconstruction problem as a constrained convex optimization problem with the total variation (TV) regularization. We then characterize the solution of the constrained convex optimization problem and show that it satisfies a system of fixed-point equations defined in terms of two proximity operators raised from the convex functions that define the TV-norm and the constrain involved in the problem. The characterization (of the solution) via the proximity operators that define two projection operators naturally leads to an alternating projection algorithm for finding the solution. For efficient numerical computation, we introduce to the alternating projection algorithm a preconditioning matrix (the EM-preconditioner) for the dense system matrix involved in the optimization problem. We prove theoretically convergence of the preconditioned alternating projection algorithm. In numerical experiments, performance of our algorithms, with an appropriately selected preconditioning matrix, is compared with performance of the conventional MAP expectation-maximization (MAP-EM) algorithm with TV regularizer (EM-TV) and that of the recently developed nested EM-TV algorithm for ECT reconstruction. Based on the numerical experiments performed in this work, we observe that the alternating projection algorithm with the EM-preconditioner outperforms significantly the EM-TV in all aspects including the convergence speed, the noise in the reconstructed images and the image quality. It also outperforms the nested EM-TV in the convergence speed while providing comparable image quality.


  • Fast proximity algorithm for MAP ECT reconstruction

    by Si Li, Andrzej Krol, Lixin Shen, Yuesheng Xu

    We arrived at the fixed-point formulation of the total variation maximum a posteriori (MAP) regularized emission computed tomography (ECT) reconstruction problem and we proposed an iterative alternating scheme to numerically calculate the fixed point. We theoretically proved that our algorithm converges to unique solutions. Because the obtained algorithm exhibits slow convergence speed, we further developed the proximity algorithm in the transformed image space, i.e. the preconditioned proximity algorithm. We used the bias-noise curve method to select optimal regularization hyperparameters for both our algorithm and expectation maximization with total variation regularization (EM-TV). We showed in the numerical experiments that our proposed algorithms, with an appropriately selected preconditioner, outperformed conventional EM-TV algorithm in many critical aspects, such as comparatively very low noise and bias for Shepp-Logan phantom. This has major ramification for nuclear medicine because clinical implementation of our preconditioned fixed-point algorithms might result in very significant radiation dose reduction in the medical applications of emission tomography.


  • Soft tissue small avascular tumor imaging with x-ray phase-contrast micro-CT in-line holography

    by Yakov Nesterets, Tim Gureyev, Andrew Stevenson, Andrew Pogany, Steve Wilkins, Russell Kincaid, Hongwei Ye, Levon Vogelsang, Edward Lipson, Ioana Coman, et al.

    To assess the feasibility of small soft tissue avascular tumor micro-CT imaging with x-ray phase-contrast in-line holography, we have studied micro-CT imaging with in-line geometry of small spheroidal avascular tumor models with quiescent cell core (< 250 μm) and various distributions of the proliferating cell density (PCD) forming the outer shell. We have simulated imaging with an ultrafast laser-based x-ray source with a Mo target. We observe phase-contrast enhancement of the tumor boundaries in the reconstructed transaxial images, resulting in improved detection of small soft tissue tumors, providing that the PCD density gradient is sufficiently large.


  • Parametric dynamic F-18-FDG PET/CT breast imaging

    by Alphonso Magri, David Feiglin, Edward Lipson, James Mandel, Wendy McGraw, Wei Lee, Andrzej Krol

    This study was undertaken to estimate metabolic tissue properties from dynamic breast F-18-FDG PET/CT image series and to display them as 3D parametric images. Each temporal PET series was obtained immediately after injection of 10 mCi of F-18-FDG and consisted of fifty 1- minute frames. Each consecutive frame was nonrigidly registered to the first frame using a finite element method (FEM) based model and fiducial skin markers. Nonlinear curve fitting of activity vs. time based on a realistic two-compartment model was performed for each voxel of the volume. Curve fitting was accomplished by application of the Levenburg-Marquardt algorithm (LMA) that minimized X2. We evaluated which parameters are most suitable to determine the spatial extent and malignancy in suspicious lesions. In addition, Patlak modeling was applied to the data. A mixture model was constructed and provided a classification system for the breast tissue. It produced unbiased estimation of the spatial extent of the lesions. We conclude that nonrigid registration followed by voxel-by-voxel based nonlinear fitting to a realistic two-compartment model yields better quality parametric images, as compared to unprocessed dynamic breast PET time series. By comparison with the mixture model, we established that the total cumulated activity and maximum activity parametric images provide the best delineation of suspicious breast tissue lesions and hyperactive subregions within the lesion that cannot be discerned in unprocessed images.

  • Application of Phase Correlation to the Montage Synthesis and Three-Dimensional Reconstruction of Large Tissue Volumes from Confocal Laser Scanning Microscopy

    by Mohamed-Adel Slamani, Andrzej Krol, Jacques Beaumont, Robert L. Price, Ioana L. Coman, Edward D. Lipson

    We have implemented and tested a new automatic method for the montage synthesis and three-dimensional (3D) reconstruction of large tissue volumes from confocal laser scanning microscopy data (CLSM). This method relies on maximization of the phase correlation between adjacent images. It was tested on a large specimen (a murine heart) that was cut into a number of individual sections with thickness appropriate for CLSM. The sections were scanned horizontally (in-plane) and vertically (perpendicular to the optical planes) to produce “tiles” of a 3D volume. Phase correlation maximization was applied to the montage synthesis of in-plane tiles and 3D alignment of optical slices within a given physical section. The performance of the new method is evaluated.


  • Motion correction via nonrigid coregistration of dynamic MR mammography series

    by Andrzej Krol, Alphonso Magri, Mehmet Unlu, David Feiglin, Edward Lipson, James Mandel, Gwen Tillapaugh-Fay, Wei Lee, Ioana Coman, Nikolaus M. Szeverenyi

    The objectives of this investigation are to improve quality of subtraction MR breast images and improve accuracy of time-signal intensity curves (TSIC) related to local contrast-agent concentration in dynamic MR mammography. The patients, with up to nine fiducial skin markers (FSMs) taped to each breast, were prone with both breasts suspended into a single well that housed the receiver coil. After a preliminary scan, paramagnetic contrast agent gadopentate digmeglumine (Gd) was delivered intravenously, followed by physiological saline. The field of view was centered over the breasts. We used a gradient recalled echo (GRE) technique for pre-Gd baseline, and five more measurements at 60s intervals. Centroids were determined for corresponding FSMs visible on pre-Gd and any post-Gd images. This was followed by segmentation of breast surfaces in all dynamic-series images, and meshing of all post-Gd breast images. Tetrahedral volume and triangular surface elements were used to construct a finite element method (FEM) model. We used ANSYSTM software and an analogy between orthogonal components of the displacement field and the temperature differences in steady-state heat transfer (SSHT) in solids. The floating images were warped to a fixed image using an appropriate shape function for interpolation from mesh nodes to voxels. To reduce any residual misregistration, we performed surface matching between the previously warped floating image and the target image. Our method of motion correction via nonrigid coregistration yielded excellent differential-image series that clearly revealed lesions not visible in unregistered differential-image series. Further, it produced clinically useful maximum intensity projection (MIP) 3D images.