Manuela Rodrigues Neiva Fernandes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manuela Rodrigues Neiva Fernandes has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Lívia Guerreiro de Barros Bentes
Universidade do Estado do Pará, Brasil
5 shared publications - Deivid Ramos dos Santos
Universidade do Estado do Pará, Brazil
4 shared publications - Rafael Silva Lemos
Universidade do Estado do Pará, Brasil
3 shared publications - Antônio Leonardo Jatahi Cavalcanti Pimentel
Universidade do Estado do Pará, Brazil
2 shared publications - Daniela Ferreira Tramontin
Universidade do Estado do Pará, Brazil
2 shared publications - Dário Santana Neto
Universidade do Estado do Pará, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 40, e405225
“Gotta have balls”: bovine testicles and video magnification imaging in the varicocelectomy training
Purpose: To describe the varicocelectomy model using bull testicles and to evaluate microsurgical practice using the surgical microscope and video magnification system.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 40, e405225
Open Access“Gotta have balls”: bovine testicles and video magnification imaging in the varicocelectomy training
Purpose: To describe the varicocelectomy model using bull testicles and to evaluate microsurgical practice using the surgical microscope and video magnification system.
- Open Access
- 25 January 2023
- Published by Archives of Endocrinology and Metabolism in Archives of Endocrinology and Metabolism
- Vol. 67 (3) , 372-377
Profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective
Objective: To describe the distribution profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective. Materials and methods: This is a retrospective, detailed and descriptive study built on secondary data obtained from the Hospital Information System of the Unified Health System (SIH/SUS). We organized the data in tables and grouped them according to the federative unit, macro-region, type of procedure, mortality rate, and year of performance. We performed statistical analysis using the χ2 test to assess [...] ABSTRACT Objective: To describe the distribution profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective. Materials and methods: This is a retrospective, detailed and descriptive study built on secondary data obtained from the Hospital Information System of the Unified Health System (SIH/SUS). We organized the data in tables and grouped them according to the federative unit, macro-region, type of procedure, mortality rate, and year of performance. We performed statistical analysis using the χ2 test to assess
- 25 January 2023
- Published by Archives of Endocrinology and Metabolism in Archives of Endocrinology and Metabolism
- Vol. 67 (3) , 372-377
Open AccessProfile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective
Objective: To describe the distribution profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective. Materials and methods: This is a retrospective, detailed and descriptive study built on secondary data obtained from the Hospital Information System of the Unified Health System (SIH/SUS). We organized the data in tables and grouped them according to the federative unit, macro-region, type of procedure, mortality rate, and year of performance. We performed statistical analysis using the χ2 test to assess [...] ABSTRACT Objective: To describe the distribution profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective. Materials and methods: This is a retrospective, detailed and descriptive study built on secondary data obtained from the Hospital Information System of the Unified Health System (SIH/SUS). We organized the data in tables and grouped them according to the federative unit, macro-region, type of procedure, mortality rate, and year of performance. We performed statistical analysis using the χ2 test to assess
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Revista do Colégio Brasileiro de Cirurgiões
- Vol. 49, e20223217
Low cost and easy acquisition: corn grain in microsurgery training
Objectives: develop an easily accessible model for training the initial motor practice in microsurgery using corn kernels. Methods: ten corn kernels (Zea mays) were used. A 7mm longitudinal cut was made on one side of the corn grain. The training consisted of performing 4 simple knots between the edges of the incision, using 10-0 mononylon thread. The parameters analyzed were 1) cost of the model; 2) assembly time of the model test system; 3) time for performing the knots; 4) distance between the knots. Results: in all corn kernels tested, it was possible to perform the proposed microsurgical suture training, without any difficulty in the procedure. The average time to perform the 4 knots was 6.51±1.18 minutes. The total cost of the simulator model was R$3.59. The average distance between the knots was 1.7±0.3mm. The model developed from corn grains has an extremely low cost when compared to the use of animals or high-tech simulators. Other advantages are the easy availability of canned corn kernels and the possibility of making more than four knots along the 7mm incision. Conclusion: the training model developed has low cost, is easy to acquire and viable for training basic manual skills in microsurgery.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Revista do Colégio Brasileiro de Cirurgiões
- Vol. 49, e20223217
Open AccessLow cost and easy acquisition: corn grain in microsurgery training
Objectives: develop an easily accessible model for training the initial motor practice in microsurgery using corn kernels. Methods: ten corn kernels (Zea mays) were used. A 7mm longitudinal cut was made on one side of the corn grain. The training consisted of performing 4 simple knots between the edges of the incision, using 10-0 mononylon thread. The parameters analyzed were 1) cost of the model; 2) assembly time of the model test system; 3) time for performing the knots; 4) distance between the knots. Results: in all corn kernels tested, it was possible to perform the proposed microsurgical suture training, without any difficulty in the procedure. The average time to perform the 4 knots was 6.51±1.18 minutes. The total cost of the simulator model was R$3.59. The average distance between the knots was 1.7±0.3mm. The model developed from corn grains has an extremely low cost when compared to the use of animals or high-tech simulators. Other advantages are the easy availability of canned corn kernels and the possibility of making more than four knots along the 7mm incision. Conclusion: the training model developed has low cost, is easy to acquire and viable for training basic manual skills in microsurgery.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Revista do Colégio Brasileiro de Cirurgiões
- Vol. 49
Baixo custo e fácil aquisição: grãos de milho no treinamento microcirúrgico
RESUMO Objetivo: desenvolver um modelo facilmente acessível para o treinamento da prática motora inicial em microcirurgia a partir da utilização de grãos de milho. Métodos: foram utilizados dez grãos de milho (Zea mays). Realizou-se um corte longitudinal de 7mm em uma das faces do grão de milho. O treinamento consistiu na realização de 4 pontos simples entre as bordas da incisão, utilizando fio de mononáilon 10-0. Os parâmetros analisados foram 1) custo do modelo; 2) tempo de montagem do sistema de teste do modelo; 3) tempo de realização dos nós; 4) distância entre os pontos. Resultados: em todos os grãos testados foi possível realizar o treinamento de sutura microcirúrgica proposto, sem dificuldade ao procedimento. O tempo médio para a realização dos 4 pontos foi de 6,51±1,18 minutos. O custo total do modelo simulatório foi de R$3,59. A distância média entre os pontos foi de 1,7±0,3mm. O modelo desenvolvido a partir de grãos de milhos apresenta custo extremamente baixo quando comparado ao uso de animais ou de simuladores de alta tecnologia. Outras vantagens são fácil disponibilidade de grãos de milho em conserva e possibilidade de serem realizados mais de quatro pontos ao longo da incisão de 7mm. Conclusão: o modelo de treinamento desenvolvido é de baixo custo, de fácil aquisição e viável para o treinamento de habilidades manuais básicas em microcirurgia.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Revista do Colégio Brasileiro de Cirurgiões
- Vol. 49
Open AccessBaixo custo e fácil aquisição: grãos de milho no treinamento microcirúrgico
RESUMO Objetivo: desenvolver um modelo facilmente acessível para o treinamento da prática motora inicial em microcirurgia a partir da utilização de grãos de milho. Métodos: foram utilizados dez grãos de milho (Zea mays). Realizou-se um corte longitudinal de 7mm em uma das faces do grão de milho. O treinamento consistiu na realização de 4 pontos simples entre as bordas da incisão, utilizando fio de mononáilon 10-0. Os parâmetros analisados foram 1) custo do modelo; 2) tempo de montagem do sistema de teste do modelo; 3) tempo de realização dos nós; 4) distância entre os pontos. Resultados: em todos os grãos testados foi possível realizar o treinamento de sutura microcirúrgica proposto, sem dificuldade ao procedimento. O tempo médio para a realização dos 4 pontos foi de 6,51±1,18 minutos. O custo total do modelo simulatório foi de R$3,59. A distância média entre os pontos foi de 1,7±0,3mm. O modelo desenvolvido a partir de grãos de milhos apresenta custo extremamente baixo quando comparado ao uso de animais ou de simuladores de alta tecnologia. Outras vantagens são fácil disponibilidade de grãos de milho em conserva e possibilidade de serem realizados mais de quatro pontos ao longo da incisão de 7mm. Conclusão: o modelo de treinamento desenvolvido é de baixo custo, de fácil aquisição e viável para o treinamento de habilidades manuais básicas em microcirurgia.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 37 (8)
Anatomical description of the extratemporal facial nerve under high-definition system: a microsurgical study in rats
To describe the microsurgical anatomical aspects of the extratemporal facial nerve of Wistar rats under a high-definition video system. Ten male Wistar rats (12–15 weeks old), without veterinary diseases, weighing 220–280 g, were used in this study. All animals in this study were submitted to the same protocol and by the same surgeon. A 10-mm incision was made below the bony prominence of the right or left ear, and extended towards the angle of the mandible. The dissection was performed and the main branches of the facial nerve were dissected. The main trunk of the facial nerve has a length of 0.88 ± 0.10 mm and a length of 3.81 ± 1.03 mm, measured from its emergence from the stylomastoid foramen to its bifurcation. Seven branches originating from the facial nerve were identified: posterior auricular, posterior cervical, cervical, mandibular, buccal, temporal, and zygomatic. The anatomy of the facial nerve is comparable to that of humans, with some variations. The most observed anatomical division was the distribution in posterior auricular, posterior cervical, cervical, mandibular, buccal, temporal, and zygomatic branches. There is no statistical difference between the thickness and distance of the structures compared to the contralateral side.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 37 (8)
Open AccessAnatomical description of the extratemporal facial nerve under high-definition system: a microsurgical study in rats
To describe the microsurgical anatomical aspects of the extratemporal facial nerve of Wistar rats under a high-definition video system. Ten male Wistar rats (12–15 weeks old), without veterinary diseases, weighing 220–280 g, were used in this study. All animals in this study were submitted to the same protocol and by the same surgeon. A 10-mm incision was made below the bony prominence of the right or left ear, and extended towards the angle of the mandible. The dissection was performed and the main branches of the facial nerve were dissected. The main trunk of the facial nerve has a length of 0.88 ± 0.10 mm and a length of 3.81 ± 1.03 mm, measured from its emergence from the stylomastoid foramen to its bifurcation. Seven branches originating from the facial nerve were identified: posterior auricular, posterior cervical, cervical, mandibular, buccal, temporal, and zygomatic. The anatomy of the facial nerve is comparable to that of humans, with some variations. The most observed anatomical division was the distribution in posterior auricular, posterior cervical, cervical, mandibular, buccal, temporal, and zygomatic branches. There is no statistical difference between the thickness and distance of the structures compared to the contralateral side.