IHIman Habibagahi

Iman Habibagahi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iman Habibagahi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A closed loop fully automated wireless vagus nerve stimulation system

    by Roshan Pathitharayil Mathews, Iman Habibagahi, Hamid Jafari Sharemi, Ronald Challita, Steven Cha, Aydin Babakhani

    Vagus nerve stimulation (VNS) has been explored as a treatment for a range of conditions, including epilepsy, cardiovascular disorders, drug-resistant depression, chronic pain, and obesity. Conventionally, VNS is administered using an open-loop approach, in which trained personnel adjust stimulation parameters. Medical supervision is necessary to minimize adverse effects, such as severe bradycardia, which can significantly interfere with daily activities. This requirement limits the feasibility of VNS in unsupervised settings and highlights the need for an automated control system. To address this limitation, we introduce the fully automated wireless VNS (FAW-VNS) system, which dynamically adjusts stimulation parameters to maintain steady-state operation while minimizing bradycardia. The FAW-VNS system operates in real-time and consists of a biocompatible, miniaturized, wirelessly powered implant equipped with cuff electrodes; a handheld device for power delivery and stimulation protocol communication; a sensing patch to collect and transmit heart rate (HR) data; and a central control unit (CCU) that updates stimulation protocols based on the acquired physiological signals. In-vivo studies were conducted on four anesthetized pigs to validate the system’s ability to reach a steady-state response, achieving a controlled HR reduction within 2–4% of baseline during stimulation. This work lays the foundation for developing closed-loop, wireless implants for point-of-care applications.


  • Robust Communication and Power Transfer Over a Single Loosely Coupled Inductive Link for Miniaturized and Batteryless Sensing Devices

    by Hamid Jafari Sharemi, Iman Habibagahi, Roshan P. Mathews, Aydin Babakhani

    This paper presents an innovative dual-mode system as well as design techniques to realize full-duplex data communication and wireless power transfer over a single inductive link. An LC tank implemented on a compact printed circuit board is shared between a rectifier that supplies the batteryless device and a power oscillator that modulates the uplink data in a time division duplex fashion. Designed to operate efficiently in the loose coupling regime, the proposed design ensures reliable performance over a substantial distance and is resilient to interference from the wireless power transfer signal. A miniaturized prototype is implemented on a printed circuit board package with a diameter of 19 mm, which is powered by a 180-nm CMOS chipset. At a data rate of 10 kbps, the coin-sized prototype achieves powering and uplink distances of 140 mm and 110 mm, respectively, offering a fivefold improvement in normalized operating range compared to recent single-coil designs of similar size. The performance of the proposed sensing device is verified by inserting a thick biological tissue between the coils and recording ex-vivo biopotential signals.


  • A Wirelessly Powered, Battery-Less, and Miniaturized Microchip for Implantable Biopotential-Monitoring Applications

    by Jaeeun Jang, Iman Habibagahi, Roshan P. Mathews, Wonseop Gwak, Hamed Rahmani, Aydin Babakhani

    This article presents a low-power, battery-less biopotential-recording integrated circuit (IC) designed for implantable leadless cardiac monitoring applications, addressing full autonomy based on wireless energy harvesting and closed-loop control. A key technical feature is the closed-loop capability with integration of a dual-band radio frequency (RF) energy harvester and communication system utilizing industrial, scientific, and medical (ISM) bands at 40.68 MHz for downlink and 915 MHz for uplink, ensuring efficient wireless power transfer and robust bidirectional data communication. The RF harvester achieves a peak conversion efficiency exceeding 40%, a critical design challenge in maintaining consistent performance under variable power conditions. Also, the proposed IC overcomes the need for a local oscillator (LO) by utilizing an externally provided clock, reducing system complexity and power consumption. Operating with a clock frequency of 100 kHz, the IC consumes only $8.8~\mu $ W, a major achievement in energy efficiency for wireless, battery-less systems. Fabricated in a 180-nm complementary metaloxidesemiconductor (CMOS) process, the IC successfully demonstrates cardiac signal measurement and heart rate (HR) extraction under a fully battery-less environment with air medium, providing a promising solution for next-generation leadless cardiac monitoring systems.


  • Open Access

    A Fully Wireless and Batteryless Localization System With 50 Micrometre Motion Detection Capability and Adaptive Transmitter Power Control for Point-of-Care Biomedical Applications

    by Arkaprova Ray, Iman Habibagahi, Aydin Babakhani

    Localization has varied applications in biomedicine, such as wireless capsule endoscopy (WCE), detection of cancerous tissue, drug delivery, robotic surgeries, and brain mapping. Currently, most localization systems are battery-powered and suffer from issues regarding battery leakage and limited battery life, resulting in potential health hazards and inconveniences when using them for continuous health monitoring applications. This paper proposes an entirely wireless and battery-less 2D localization system consisting of an integrated circuit (IC) that is wirelessly powered at a distance of 4 cm by a 40.68 MHz radio frequency (RF) power of only 2 W. The proposed localization system wirelessly transmits a locked sub-harmonic 13.56 MHz signal generated from the wirelessly received 40.68 MHz RF power signal, eliminating the need for a power-hungry oscillator. Additionally, the system, having a measurement latency of 11.3 ms, has also been verified to sense motion as small as 50 $\mu m$ as well as measure the rate of motion up to 10 beats per minute, therefore extending its application to the detection of physiological motions such as diaphragm motion during breathing. The localizer has a small form factor of 17 mm × 12 mm × 0.2 mm and consumes an average power of 6 $\mu$ W. Ex vivo measurements using the localizer inside the porcine intestine demonstrate a localization accuracy of less than 5 mm.


  • Miniaturized Wirelessly Powered and Controlled Implants for Multisite Stimulation

    by Iman Habibagahi, Jaeeun Jang, Aydin Babakhani

    This article presents a miniaturized implant with a diameter of only 14 mm, which houses a novel system on chip (SoC) enabling two-voltage-level stimulation of up to 16 implants using a single transmitter (Tx) coil. Each implant can operate at a distance of 80 mm in the air through the inductive resonant link. The SoC consumes only 27- $\mu \text{W}$ static power and enables two channels with stimulation amplitudes of 1.8 and 3.3 V and a timing resolution of 100 $\mu \text{s}$ . The SoC is implemented in the standard 180-nm complementary metal–oxide–semiconductor (CMOS) technology and has an area of $0.75\times1.6$ mm. The SoC comprises an RF rectifier, low dropout regulator (LDO), error detection block, clock data recovery, finite-state machine (FSM), and output stage. Each implant has a printed circuit board (PCB)-defined passcode, which enables the individual addressability of the implants for synchronized therapies. The implantable device weighs only 80 mg and sizes 20.1 mm3. Tolerance of up to 70° to angular misalignment was measured at a distance of 50 mm. The efficacy of bilateral stimulation was further verified by implanting two devices on two sides of a pig’s neck and performing bilateral vagus nerve stimulation (VNS) while monitoring the heart rate.


  • Design and Implementation of Multisite Stimulation System Using a Double-Tuned Transmitter Coil and Miniaturized Implants

    by Iman Habibagahi, Roshan P. Mathews, Arkaprova Ray, Aydin Babakhani

    This letter presents a double-tuned dual input transmitter coil operating at 13.56 and 40.68 MHz industrial, scientific, and medical (ISM) bands for multisite biomedical applications. The proposed system removes the need for two separate coils, which reduces system size and unwanted couplings. The design and analysis of the double-tuned transmitter coil using a lumped element frequency trap are discussed in this letter. The transmitter achieves measured matching of $-$ 26.2 and $-$ 21.5 dB and isolation of $-$ 17.7 and $-$ 11.7 dB at 13.56 and 40.68 MHz, respectively. A 3 $\times$ 15 mm flexible coil is used as an implantable receiver. This letter shows synchronized multisite stimulation of two flexible implants at a distance of 2 cm while covered with 1 cm chicken breast.


  • Open Access

    Vagus nerve stimulation using a miniaturized wirelessly powered stimulator in pigs

    by Iman Habibagahi, Mahmoud Omidbeigi, Joseph Hadaya, Hongming Lyu, Jaeeun Jang, Jeffrey L. Ardell, Ausaf A. Bari, Aydin Babakhani

    Neuromodulation of peripheral nerves has been clinically used for a wide range of indications. Wireless and batteryless stimulators offer important capabilities such as no need for reoperation, and extended life compared to their wired counterparts. However, there are challenging trade-offs between the device size and its operating range, which can limit their use. This study aimed to examine the functionality of newly designed wirelessly powered and controlled implants in vagus nerve stimulation for pigs. The implant used near field inductive coupling at 13.56 MHz industrial, scientific, and medical band to harvest power from an external coil. The circular implant had a diameter of 13 mm and weighed 483 mg with cuff electrodes. The efficiency of the inductive link and robustness to distance and misalignment were optimized. As a result, the specific absorption rate was orders of magnitude lower than the safety limit, and the stimulation can be performed using only 0.1 W of external power. For the first time, wireless and batteryless VNS with more than 5 cm operation range was demonstrated in pigs. A total of 84 vagus nerve stimulations (10 s each) have been performed in three adult pigs. In a quantitative comparison of the effectiveness of VNS devices, the efficiency of systems on reducing heart rate was similar in both conventional (75%) and wireless (78.5%) systems. The pulse width and frequency of the stimulation were swept on both systems, and the response for physiological markers was drawn. The results were easily reproducible, and methods used in this study can serve as a basis for future wirelessly powered implants.