YLYumeng Liang

Yumeng Liang

*This is an algorithmically generated author record based on publicly available information.

Yumeng Liang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cellulars Go Underground: Practical Obstacles and Effective Mitigation

    by Hongyi Wang, Jiaxing Qiu, Zhenhua Li, Liangyi Gong, Feng Qian, Yang Li, Jiakun Du, Zichen Zhang, Jiawei Zhen, Yunhao Liu, et al.

  • Open Access

    MCon: Building an Elastic Cloud for Android Applications with Framework Consolidation

    by Jiaxing Qiu, Zijie Zhou, Zhenhua Li, Hongyi Wang, Zizhang Liu, Yunhao Liu, Yumeng Liang, Jie Wu, Wen Xia, Tianyin Xu

  • RCNet: Resilient Collaborative DNN Inference for Wireless Networks With High Packet Loss

    by Yumeng Liang, Jianhui Chang, Mingyuan Zang, Jie Wu

    The limited computation resources of mobile devices hinders the real-time Deep Neural Network (DNN) inference, which is critical in many Internet of Things (IoT) applications. To meet the real-time responses demands, the cloud-end collaborative DNN inference is promising, which partially offloads the inference workloads from mobile devices to the cloud server with powerful computation resources through wireless networks. However, in many IoT applications, the wireless networks are of poor link conditions with high packet loss rates, which has posed a substantial obstacle to the intermediate feature transmission. In such scenarios, it is rather challenging to achieve efficient and resilient collaborative DNN inference. In this paper, we tackle this challenge by proposing a Resilient Collaborative DNN inference framework, named RCNet, to maintain high accuracy under high packet loss conditions in wireless networks. It leverages an unequal redundant encoding mechanism to efficiently prioritize the successful transmission of important features on the mobile devices, and a Transformer-based feature reconstruction module to fully leverage the powerful computation resources on the cloud server to recover the missing features. We implement a real-world testbed and conduct extensive experiments. The experimental results verify that RCNet enables robust collaborative inference with an accuracy surpassing 90%, even under extremely harsh network conditions with over 90% of features being lost.


  • Open Access

    BP3: Improving Cuff-less Blood Pressure Monitoring Performance by Fusing mmWave Pulse Wave Sensing and Physiological Factors

    by Zixin Zheng, Yumeng Liang, Rui Lyu, Junjie Bao, Yiwen Huang, Anfu Zhou, Huadong Ma, Jingjia Wang, Xiangbin Meng, Chunli Shao, et al.

    Cuff-less methods, especially pulse wave analysis (PWA) techniques with PPG/mmWave sensing, have shown great potential for non-intrusive blood pressure (BP) monitoring. However, the state-of-the-art solutions are only validated on small-scale healthy subjects, neglecting patients with abnormal BP and thus a more urgent need for BP monitoring. To bridge the gap, we first build the largest mmWave-BP dataset to our knowledge, including 930 real patients with cardiovascular diseases, and perform extensive experiments, which reveals that all existing PWA methods exhibit far less satisfactory performance with standard deviation errors (STD) exceeding 16 mmHg for systolic BP (SBP) and 11mmHg for diastolic BP (DBP). An in-depth investigation shows that physiological factors have complex effect on vascular elasticity and structure, thus people with very different BP values may exhibit extremely similar pulse waveform, which leads to confusion in model learning. In this work, we propose BP3, which fuses physiological factors into sensing-data-driven deep-learning framework, so as to capture the intricate effect of physiological factors during the whole process of learning pulse waveforms. Evaluation results show that BP3 achieves the mean errors of-1.57 mmHg and -0.34 mmHg, STD of 9.77 mmHg and 7.93 mmHg for SBP and DBP, respectively. Moreover importantly, BP3 shows remarkable gain particularly for subjects with abnormal BP, achieving mean errors that are only 0.48% ~ 20.86% of the state-of-the-art solutions.


  • Mmtaster: A Mobile System for Fine-Grained and Robust Alcohol Sensing

    by Yumeng Liang, Pu Shi, Zixin Zheng, Lingyu Pu, Anfu Zhou, Huadong Ma

    Wireless sensing offers a promising approach to identify the content of liquids without opening the container or directly touching the liquid. Although existing methods aim to achieve fine-grained identification, i.e., distinguishing a 1% v/v difference in alcohol content, they still have limitations in detecting highly deceptive counterfeit liquors that have much smaller content differences, sometimes as low as 0.2% v/v alcohol content. In this paper, we propose mmTaster , a mobile system that combines the mmWave radar with a smartphone to perform fine-grained and robust alcohol sensing. To achieve the desired fine granularity, we introduce a novel feature extraction model that exploits the unique reflection responses across multiple mmWave frequencies , which provide discriminative information about liquid content. Furthermore, we observe the serious interference of target displacement on identification performance, which hinders the various applications in mobile scenarios. To enhance the robustness, mmTaster incorporates a customized translation-invariant neural network, ConvNet , to remove the location interference and extract stable liquid-dependent features regardless of target displacement. Extensive experimental results demonstrate that mmTaster can accurately distinguish the alcohol differences as low as 0.2% v/v with an accuracy of over 90.8% even in scenarios involving diverse displacements and rotations.


  • Open Access

    airBP: Monitor Your Blood Pressure with Millimeter-Wave in the Air

    by Yumeng Liang, Anfu Zhou, Xinzhe Wen, Wei Huang, Pu Shi, Lingyu Pu, Huanhuan Zhang, Huadong Ma

    Blood pressure (BP), an important vital sign to assess human health, is expected to be monitored conveniently. The existing BP monitoring methods, either traditional cuff based or newly emerging wearable based, all require skin contact, which may cause unpleasant user experience and is even injurious to certain users. In this article, we explore contactless BP monitoring and propose airBP, which emits millimeter-wave signals toward a user’s wrist, and captures the reflected signal bounded off from the pulsating artery underlying the wrist. By analyzing the reflected signal strength of the signal, airBP generates the arterial pulse and further estimates BP by exploiting the relationship between the arterial pulse and BP. To realize airBP, we design a new beam-forming method to keep focusing on the tiny and hidden wrist artery, by leveraging the inherent periodicity of the arterial pulse. Moreover, we custom design a pre-training and neural network architecture, to combat the challenges from the arterial pulse sparsity and ambiguity, so as to estimate BP accurately. We prototype airBP using a coin-size commercial off-the-shelf millimeter-wave radar and perform extensive experiments on 41 subjects. The results demonstrate that airBP accurately estimates systolic and diastolic BP, with a mean error of –0.30 mmHg and –0.23 mmHg, as well as a standard deviation error of 4.80 mmHg and 3.79 mmHg (within the acceptable range regulated by the FDA’s AAMI protocol), respectively, at a distance up to 26 cm.


  • Robust Respiratory Rate Monitoring Using Smartwatch Photoplethysmography

    by Langcheng Zhao, Fenglin Zhang, Huanhuan Zhang, Yumeng Liang, Anfu Zhou, Huadong Ma

    Respiratory rate is of great value in health care, especially when it can be continuously monitored using wearable devices in daily life. Recent works employ Photoplethysmography (PPG) on smartwatch for continuous respiration monitoring, based on a certain medical discovery called Respiratory Sinus Arrhythmia (RSA), which describes the relationship between respiratory and heart rate. However, we find that these works fall short of robustness. In particular, the respiratory estimation accuracy drops significantly when people breathe faster (e.g., after sports). We further identify the root reason that the RSA gradually weakens as the respiratory rate increases. In this paper, we propose BreathAnalyzer, which can estimate respiratory rate accurately even at high respiratory rates. To achieve this, BreathAnalyzer boosts the weakened RSA and also handles the motion artifacts, by integrating features from multiple domains, i.e., frequency, time and non-linear Poincare domain, instead of using the single spectrum or raw signal in previous studies. Moreover, BreathAnalyzer custom-designs a tree-based learning model, which fits multi-domain features, while considering limitations of smartwatch. We implement BreathAnalyzer prototype on COTS smartwatch, and extensive evaluation demonstrates that BreathAnalyzer outperforms the state-of-the-art approaches, with accuracy improvement by 35.37% ∼ 80.42% across a variety of practical scenarios including high respiratory rates.