Yizhuang Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yizhuang Song has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dong Liu
School of Biomedical Engineering and Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, China
2 shared publications Haiyang Wang
School of Mathematics and Statistics, Shandong Normal University, Jinan, Shandong 250014, People’s Republic of China
2 shared publications- Haiyang Wang
School of Mathematics and Statistics, Shandong Normal University, Jinan 250014, China
2 shared publications - Guohao Zhang
School of Mathematics and Statistics, Shandong Normal University, Jinan 250014, China
1 shared publication Huiying Li
School of Mathematics and Statistics, Shandong Normal University, Jinan 250014, China
1 shared publicationHyeuknam Kwon
♮College of Science & Technology, Yonsei University, Wonju, South Korea
1 shared publication
Latest Publications
- Open Access
- 7 April 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (7) , 1230
Metal Artifact Reduction in CT Based on a Nonlinear Weighted Anisotropic TV Regularization
Metal artifact reduction (MAR) remains a long-standing challenge in computed tomography (CT) reconstruction. Metallic implants introduce inconsistencies between the acquired projection data and the ideal Radon transform, resulting in severe streaking artifacts in images reconstructed using the conventional filtered back projection (FBP) algorithm. In this work, we propose a nonlinear weighted anisotropic total variation (NWATV) regularization method to mitigate metal artifacts and improve CT image quality. The effectiveness of the NWATV method is evaluated through three experiments, and the results demonstrate that it achieves superior reconstruction performance compared to the conventional linear interpolation method, the normalized metal artifact reduction method and the anisotropic total variation (TV) regularization method.
- 7 April 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (7) , 1230
Open AccessMetal Artifact Reduction in CT Based on a Nonlinear Weighted Anisotropic TV Regularization
Metal artifact reduction (MAR) remains a long-standing challenge in computed tomography (CT) reconstruction. Metallic implants introduce inconsistencies between the acquired projection data and the ideal Radon transform, resulting in severe streaking artifacts in images reconstructed using the conventional filtered back projection (FBP) algorithm. In this work, we propose a nonlinear weighted anisotropic total variation (NWATV) regularization method to mitigate metal artifacts and improve CT image quality. The effectiveness of the NWATV method is evaluated through three experiments, and the results demonstrate that it achieves superior reconstruction performance compared to the conventional linear interpolation method, the normalized metal artifact reduction method and the anisotropic total variation (TV) regularization method.
- Open Access
- 1 March 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (5) , 840
Electrical Impedance Tomography Reconstruction with Partial Boundary Measurements
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that enables real-time monitoring of human organ function by reconstructing the internal conductivity distribution. In clinical settings, electrode placement is often constrained, resulting in incomplete boundary measurements and a consequent severe degradation of image reconstruction quality. In this work, we investigate EIT reconstruction under partially covered electrode boundaries using our recently proposed nonlinear weighted anisotropic total variation (NWATV) regularizer. Through numerical simulations and water tank experiments with three-quarter and half-circumferential electrode configurations, we demonstrate that NWATV significantly improves both structural fidelity and robustness in reconstructed images under partial electrode coverage. Our findings indicate that NWATV holds potential for clinical use in limited-electrode configurations.
- 1 March 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (5) , 840
Open AccessElectrical Impedance Tomography Reconstruction with Partial Boundary Measurements
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that enables real-time monitoring of human organ function by reconstructing the internal conductivity distribution. In clinical settings, electrode placement is often constrained, resulting in incomplete boundary measurements and a consequent severe degradation of image reconstruction quality. In this work, we investigate EIT reconstruction under partially covered electrode boundaries using our recently proposed nonlinear weighted anisotropic total variation (NWATV) regularizer. Through numerical simulations and water tank experiments with three-quarter and half-circumferential electrode configurations, we demonstrate that NWATV significantly improves both structural fidelity and robustness in reconstructed images under partial electrode coverage. Our findings indicate that NWATV holds potential for clinical use in limited-electrode configurations.
- 30 May 2024
- Published by IOP Publishing in Inverse Problems
- Vol. 40 (7) , 075005
Stability of the isotropic conductivity reconstruction using magnetic resonance electrical impedance tomography (MREIT)
Magnetic resonance electrical impedance tomography (MREIT) is a high-resolution imaging modality that aims to reconstruct the objects’ conductivity distributions at low frequency using the measurable z-component of the magnetic flux density obtained from an MRI scanner. Traditional reconstruction algorithms in MREIT use two datum subject to two linearly independent current densities. However, the temporal resolution of such a MREIT image is relatively low. Recently, a single current harmonic Bz algorithm has been proposed to improve the temporal resolution. Even though a series of reconstruction algorithms have been proposed in the last two decades, the theoretical studies of MREIT are still quite limited. This paper presents the stability theorems for two datum and a single data-based isotropic conductivity reconstruction using MREIT. Using the regularity theory of elliptic partial differential equations, we prove that the only instability in the inverse problem of MREIT comes from taking the second-order derivative of the measured data Bz , the z-component of the magnetic flux density. To get a stable reconstruction from the noisy Bz data, we note that the edge structure of ∇ B z reveals the edge features in the unknown conductivity and provides an edge-preserving denoising approach for the ∇ B z data. We use a modified Shepp–Logan phantom model to validate the proposed theory and the denoising approach.
- 30 May 2024
- Published by IOP Publishing in Inverse Problems
- Vol. 40 (7) , 075005
Stability of the isotropic conductivity reconstruction using magnetic resonance electrical impedance tomography (MREIT)
Magnetic resonance electrical impedance tomography (MREIT) is a high-resolution imaging modality that aims to reconstruct the objects’ conductivity distributions at low frequency using the measurable z-component of the magnetic flux density obtained from an MRI scanner. Traditional reconstruction algorithms in MREIT use two datum subject to two linearly independent current densities. However, the temporal resolution of such a MREIT image is relatively low. Recently, a single current harmonic Bz algorithm has been proposed to improve the temporal resolution. Even though a series of reconstruction algorithms have been proposed in the last two decades, the theoretical studies of MREIT are still quite limited. This paper presents the stability theorems for two datum and a single data-based isotropic conductivity reconstruction using MREIT. Using the regularity theory of elliptic partial differential equations, we prove that the only instability in the inverse problem of MREIT comes from taking the second-order derivative of the measured data Bz , the z-component of the magnetic flux density. To get a stable reconstruction from the noisy Bz data, we note that the edge structure of ∇ B z reveals the edge features in the unknown conductivity and provides an edge-preserving denoising approach for the ∇ B z data. We use a modified Shepp–Logan phantom model to validate the proposed theory and the denoising approach.
- Open Access
- 1 January 2024
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 21 (4) , 5047-5067
Sparse-view X-ray CT based on a box-constrained nonlinear weighted anisotropic TV regularization
Sparse-view computed tomography (CT) is an important way to reduce the negative effect of radiation exposure in medical imaging by skipping some X-ray projections. However, due to violating the Nyquist/Shannon sampling criterion, there are severe streaking artifacts in the reconstructed CT images that could mislead diagnosis. Noting the ill-posedness nature of the corresponding inverse problem in a sparse-view CT, minimizing an energy functional composed by an image fidelity term together with properly chosen regularization terms is widely used to reconstruct a medical meaningful attenuation image. In this paper, we propose a regularization, called the box-constrained nonlinear weighted anisotropic total variation (box-constrained NWATV), and minimize the regularization term accompanying the least square fitting using an alternative direction method of multipliers (ADMM) type method. The proposed method is validated through the Shepp-Logan phantom model, alongisde the actual walnut X-ray projections provided by Finnish Inverse Problems Society and the human lung images. The experimental results show that the reconstruction speed of the proposed method is significantly accelerated compared to the existing $ L_1/L_2 $ regularization method. Precisely, the central processing unit (CPU) time is reduced more than 8 times.- 1 January 2024
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 21 (4) , 5047-5067
Open AccessSparse-view X-ray CT based on a box-constrained nonlinear weighted anisotropic TV regularization
Sparse-view computed tomography (CT) is an important way to reduce the negative effect of radiation exposure in medical imaging by skipping some X-ray projections. However, due to violating the Nyquist/Shannon sampling criterion, there are severe streaking artifacts in the reconstructed CT images that could mislead diagnosis. Noting the ill-posedness nature of the corresponding inverse problem in a sparse-view CT, minimizing an energy functional composed by an image fidelity term together with properly chosen regularization terms is widely used to reconstruct a medical meaningful attenuation image. In this paper, we propose a regularization, called the box-constrained nonlinear weighted anisotropic total variation (box-constrained NWATV), and minimize the regularization term accompanying the least square fitting using an alternative direction method of multipliers (ADMM) type method. The proposed method is validated through the Shepp-Logan phantom model, alongisde the actual walnut X-ray projections provided by Finnish Inverse Problems Society and the human lung images. The experimental results show that the reconstruction speed of the proposed method is significantly accelerated compared to the existing $ L_1/L_2 $ regularization method. Precisely, the central processing unit (CPU) time is reduced more than 8 times. - 16 May 2023
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Imaging Sciences
- Vol. 16 (2) , 706-739
Convergence Analysis of the Harmonic \(\boldsymbol{B_{{z}}}\) Algorithm with Single Injection Current in MREITMagnetic resonance electrical impedance tomography (MREIT) aims to recover the electrical conductivity distribution of an object using partial information of magnetic flux densities inside the tissue which can be measured using a magnetic resonance imaging scanner, with the advantage that a higher spatial resolution of conductivity image can be provided than existing EIT techniques involving surface measurements. Traditional MREIT reconstruction algorithms use two data sets obtained with two linearly independent injected currents. However, injection of two currents is often not possible in applications such as transcranial electrical stimulation. Recently, we proposed an iterative conductivity reconstruction algorithm called the single-current harmonic [Formula: see text] algorithm that demonstrated satisfactory performance in numerical and phantom tests. In this paper, we provide a rigorous mathematical analysis of the convergence of the iterative sequence for realizing this algorithm. We prove that, applying some mild conditions on the exact conductivity, the iterative sequence converges to the true solution within an explicit error bound. Such theoretical results substantiate the reasonability and efficiency of the proposed algorithm. We also provide more numerical evidence to validate these theoretical results.
- 16 May 2023
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Imaging Sciences
- Vol. 16 (2) , 706-739
Convergence Analysis of the Harmonic \(\boldsymbol{B_{{z}}}\) Algorithm with Single Injection Current in MREITMagnetic resonance electrical impedance tomography (MREIT) aims to recover the electrical conductivity distribution of an object using partial information of magnetic flux densities inside the tissue which can be measured using a magnetic resonance imaging scanner, with the advantage that a higher spatial resolution of conductivity image can be provided than existing EIT techniques involving surface measurements. Traditional MREIT reconstruction algorithms use two data sets obtained with two linearly independent injected currents. However, injection of two currents is often not possible in applications such as transcranial electrical stimulation. Recently, we proposed an iterative conductivity reconstruction algorithm called the single-current harmonic [Formula: see text] algorithm that demonstrated satisfactory performance in numerical and phantom tests. In this paper, we provide a rigorous mathematical analysis of the convergence of the iterative sequence for realizing this algorithm. We prove that, applying some mild conditions on the exact conductivity, the iterative sequence converges to the true solution within an explicit error bound. Such theoretical results substantiate the reasonability and efficiency of the proposed algorithm. We also provide more numerical evidence to validate these theoretical results.
- 7 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Nonlinear Weighted Anisotropic Total Variation Regularization for Electrical Impedance Tomography
This paper proposes a nonlinear weighted anisotropic total variation (NWATV) regularization technique for electrical impedance tomography (EIT). The key idea is to incorporate the internal inhomogeneity information (e.g., edges of the detected objects) into the EIT reconstruction process, aiming to preserve the conductivity profiles (to be detected). We study the NWATV image reconstruction by employing a novel soft thresholding based reformulation included in the alternating direction method of multipliers (ADMM). To evaluate the proposed approach, numerical simulations and human EIT lung imaging are carried out. It is demonstrated that the properties of the internal inhomogeneity are well preserved and improved with the proposed regularization approach, in comparison to traditional total variation (TV) and recently proposed fidelity embedded regularization approaches. Owing to the simplicity of the proposed method, the computational cost is significantly decreased compared with the well established primal-dual algorithm. Precisely, with the proposed algorithm, we are able to alleviate the staircase effect arising in TV regularization and improve the reconstruction accuracy for FER does. To achieve similar accuracy as TV does, the computational times are reduced from 2.311s to 0.629s and 1.733s to 0.428s in 2D and 3D simulations, respectively, and the computational time is reduced from greater than 2s to less than 0.2s in the human experiment. Meanwhile, it was found that the proposed regularization method is quite robust to the measurement noise, which is one of the main uncertainties in EIT.
- 7 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Nonlinear Weighted Anisotropic Total Variation Regularization for Electrical Impedance Tomography
This paper proposes a nonlinear weighted anisotropic total variation (NWATV) regularization technique for electrical impedance tomography (EIT). The key idea is to incorporate the internal inhomogeneity information (e.g., edges of the detected objects) into the EIT reconstruction process, aiming to preserve the conductivity profiles (to be detected). We study the NWATV image reconstruction by employing a novel soft thresholding based reformulation included in the alternating direction method of multipliers (ADMM). To evaluate the proposed approach, numerical simulations and human EIT lung imaging are carried out. It is demonstrated that the properties of the internal inhomogeneity are well preserved and improved with the proposed regularization approach, in comparison to traditional total variation (TV) and recently proposed fidelity embedded regularization approaches. Owing to the simplicity of the proposed method, the computational cost is significantly decreased compared with the well established primal-dual algorithm. Precisely, with the proposed algorithm, we are able to alleviate the staircase effect arising in TV regularization and improve the reconstruction accuracy for FER does. To achieve similar accuracy as TV does, the computational times are reduced from 2.311s to 0.629s and 1.733s to 0.428s in 2D and 3D simulations, respectively, and the computational time is reduced from greater than 2s to less than 0.2s in the human experiment. Meanwhile, it was found that the proposed regularization method is quite robust to the measurement noise, which is one of the main uncertainties in EIT.
- Open Access
A nonlinear weighted anisotropic total variation regularization for electrical impedance tomography
This paper proposes a nonlinear weighted anisotropic total variation (NWATV) regularization technique for electrical impedance tomography (EIT). The key idea is to incorporate the internal inhomogeneity information (e.g., edges of the detected objects) into the EIT reconstruction process, aiming to preserve the conductivity profiles (to be detected). We study the NWATV image reconstruction by employing a novel soft thresholding based reformulation included in the alternating direction method of multipliers (ADMM). To evaluate the proposed approach, 2D and 3D numerical experiments and human EIT lung imaging are carried out. It is demonstrated that the properties of the internal inhomogeneity are well preserved and improved with the proposed regularization approach, in comparison to traditional total variation (TV) and recently proposed fidelity embedded regularization approaches. Owing to the simplicity of the proposed method, the computational cost is significantly decreased compared with the well established primal-dual algorithm. Meanwhile, it was found that the proposed regularization method is quite robust to the measurement noise, which is one of the main uncertainties in EIT.
Open AccessA nonlinear weighted anisotropic total variation regularization for electrical impedance tomography
This paper proposes a nonlinear weighted anisotropic total variation (NWATV) regularization technique for electrical impedance tomography (EIT). The key idea is to incorporate the internal inhomogeneity information (e.g., edges of the detected objects) into the EIT reconstruction process, aiming to preserve the conductivity profiles (to be detected). We study the NWATV image reconstruction by employing a novel soft thresholding based reformulation included in the alternating direction method of multipliers (ADMM). To evaluate the proposed approach, 2D and 3D numerical experiments and human EIT lung imaging are carried out. It is demonstrated that the properties of the internal inhomogeneity are well preserved and improved with the proposed regularization approach, in comparison to traditional total variation (TV) and recently proposed fidelity embedded regularization approaches. Owing to the simplicity of the proposed method, the computational cost is significantly decreased compared with the well established primal-dual algorithm. Meanwhile, it was found that the proposed regularization method is quite robust to the measurement noise, which is one of the main uncertainties in EIT.
- 17 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (22) , 225016
Low frequency conductivity reconstruction based on a single current injection via MREIT
Conventional magnetic resonance electrical impedance tomography (MREIT) reconstruction methods require administration of two linearly independent currents via at least two electrode pairs. This requires long scanning times and inhibits coordination of MREIT measurements with electrical neuromodulation strategies. We sought to develop an isotropic conductivity reconstruction algorithm in MREIT based on a single current injection, both to decrease scanning time by a factor of two and enable MREIT measurements to be conveniently adapted to general transcranial- or implanted-electrode neurostimulation protocols. In this work, we propose and demonstrate an iterative algorithm that extends previously published MREIT work using two-current administration approaches. The proposed algorithm is a single-current adaptation of the harmonic B z algorithm. Forward modeling of electric potentials is used to capture changes of conductivity along current directions that would normally be invisible using data from a single-current administration. Computational and experimental results show that the reconstruction algorithm is capable of reconstructing isotropic conductivity images that agree well in terms of L 2 error and structural similarity with exact conductivity distributions or two-current-based MREIT reconstructions. We conclude that it is possible to reconstruct high quality electrical conductivity images using MREIT techniques and one current injection only.
- 17 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (22) , 225016
Low frequency conductivity reconstruction based on a single current injection via MREIT
Conventional magnetic resonance electrical impedance tomography (MREIT) reconstruction methods require administration of two linearly independent currents via at least two electrode pairs. This requires long scanning times and inhibits coordination of MREIT measurements with electrical neuromodulation strategies. We sought to develop an isotropic conductivity reconstruction algorithm in MREIT based on a single current injection, both to decrease scanning time by a factor of two and enable MREIT measurements to be conveniently adapted to general transcranial- or implanted-electrode neurostimulation protocols. In this work, we propose and demonstrate an iterative algorithm that extends previously published MREIT work using two-current administration approaches. The proposed algorithm is a single-current adaptation of the harmonic B z algorithm. Forward modeling of electric potentials is used to capture changes of conductivity along current directions that would normally be invisible using data from a single-current administration. Computational and experimental results show that the reconstruction algorithm is capable of reconstructing isotropic conductivity images that agree well in terms of L 2 error and structural similarity with exact conductivity distributions or two-current-based MREIT reconstructions. We conclude that it is possible to reconstruct high quality electrical conductivity images using MREIT techniques and one current injection only.