Heaklig Ayala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heaklig Ayala has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Olayiwola Alatise
School of Engineering, University of Warwick, Coventry CV4 7AL, UK
4 shared publications - Asad Mahmood
University of Warwick, Coventry
3 shared publications Jose Ortiz Gonzalez
3 shared publications- Jose Ortiz Gonzalez
University of Warwick
3 shared publications - Saeed Jahdi
University of Bristol
3 shared publications - Xinzhi Liu
Electrical Engineering Department School of Engineering University of Warwick Coventry UK
3 shared publications
Latest Publications
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (6) , 3308-3320
Correlations Between Body Diode Pulsed Overcurrent Safe Operating Area, Short Circuit, and Avalanche Ruggedness in SiC MOSFETs
Power MOSFETs are sometimes taken outside their safe operating area (SOA). This can be during pulsed overcurrents, avalanche conduction mode during unclamped inductive switching (UIS) or short-circuit events. These conditions present different stresses to the device. In pulsed overcurrent conditions, the device is subject to overcurrents at low voltage; in UIS, the device is subject to overvoltage at low currents; and in short circuits, the device is subject to both. The ability of the MOSFET to withstand these conditions is a key robustness metric. How robustness under these three electrothermal shock events correlates with one another is yet to be investigated systematically. The objective of this article is to correlate these metrics in SiC MOSFETs by characterizing planar, asymmetric trench, and double-trench device structures. The critical energies to failure have been determined for all devices under the three undesired operating conditions, and correlations have been made. The maximum junction temperatures have been inferred by temperature-sensitive electrical parameters and confirmed with electrothermal simulations. The analysis in this article demonstrates that the critical avalanche and surge energies to failure are directly correlated, and they increase with stress duration. Furthermore, a tradeoff between short-circuit robustness and surge/avalanche robustness is observed based on device-specific on-state resistance.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (6) , 3308-3320
Correlations Between Body Diode Pulsed Overcurrent Safe Operating Area, Short Circuit, and Avalanche Ruggedness in SiC MOSFETs
Power MOSFETs are sometimes taken outside their safe operating area (SOA). This can be during pulsed overcurrents, avalanche conduction mode during unclamped inductive switching (UIS) or short-circuit events. These conditions present different stresses to the device. In pulsed overcurrent conditions, the device is subject to overcurrents at low voltage; in UIS, the device is subject to overvoltage at low currents; and in short circuits, the device is subject to both. The ability of the MOSFET to withstand these conditions is a key robustness metric. How robustness under these three electrothermal shock events correlates with one another is yet to be investigated systematically. The objective of this article is to correlate these metrics in SiC MOSFETs by characterizing planar, asymmetric trench, and double-trench device structures. The critical energies to failure have been determined for all devices under the three undesired operating conditions, and correlations have been made. The maximum junction temperatures have been inferred by temperature-sensitive electrical parameters and confirmed with electrothermal simulations. The analysis in this article demonstrates that the critical avalanche and surge energies to failure are directly correlated, and they increase with stress duration. Furthermore, a tradeoff between short-circuit robustness and surge/avalanche robustness is observed based on device-specific on-state resistance.
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Inspection Techniques Using Scanning Acoustic Microscopy for Silver Sintering Applications in Power Electronic Modules
This work presents a practical perspective to Scanning Acoustic Microscopy (SAM) for Ag-sintering applications in power electronic modules and devices. It aims to present typical challenges to consider whilst performing C-SAM for inspecting and analysing microstructures within power electronic devices, with emphasis on silver-sintered interconnects. The study presents a vast number of acoustic images (discrete devices in TO-247 packages, power modules, and also custom samples of substrates and devices), where several defects are identified, including voids, cracks, and delamination. Challenges for Ag-sintered layers inspection related to advanced surface finishes are also revealed and discussed in detail. The suitability of C-SAM for inspecting small and large areas of Ag-sintered interfaces is discussed, and showcased with custom samples, and a commercial power module.
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Inspection Techniques Using Scanning Acoustic Microscopy for Silver Sintering Applications in Power Electronic Modules
This work presents a practical perspective to Scanning Acoustic Microscopy (SAM) for Ag-sintering applications in power electronic modules and devices. It aims to present typical challenges to consider whilst performing C-SAM for inspecting and analysing microstructures within power electronic devices, with emphasis on silver-sintered interconnects. The study presents a vast number of acoustic images (discrete devices in TO-247 packages, power modules, and also custom samples of substrates and devices), where several defects are identified, including voids, cracks, and delamination. Challenges for Ag-sintered layers inspection related to advanced surface finishes are also revealed and discussed in detail. The suitability of C-SAM for inspecting small and large areas of Ag-sintered interfaces is discussed, and showcased with custom samples, and a commercial power module.
- 18 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Investigation of the Drain-Source Leakage Current Early Transients During HTRB Reliability Tests
High Temperature Reverse Bias (HTRB) is a qualification and reliability test, where devices are subject to high temperature and reverse voltage bias for a defined amount of time (typically 1000 hours), while the drain-source leakage current is monitored. The devices can fail or exhibit patterns of failure at the early stages; hence, it is important to understand the early transient behaviour of the leakage currents while the devices are under test. Moreover, during HTRB, a large number of devices are usually stressed and monitored in parallel. In this paper, two 1200 V SiC MOSFETs of similar current ratings (trench and planar) were investigated. Different experiments have been performed to investigate the exponentially decaying transient of the drain-source leakage current, and the differences between monitoring individual discrete devices and monitoring discrete devices grouped together. Experimental results show that when stressing devices in parallel the exponential decay is common to all the devices, with the total current being the result of adding the individual leakage currents. The impact of the stress voltage applied to the devices (700 to 1000 V) and temperature (50 to 150°C) was also investigated. The results show that generally, the transient time is shorter at lower temperatures, and that it increases as the stress voltage increases. Additionally, the investigated devices showed different relaxation time constants in the orders of thousands (trench) and hundreds (planar) of seconds.
- 18 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Investigation of the Drain-Source Leakage Current Early Transients During HTRB Reliability Tests
High Temperature Reverse Bias (HTRB) is a qualification and reliability test, where devices are subject to high temperature and reverse voltage bias for a defined amount of time (typically 1000 hours), while the drain-source leakage current is monitored. The devices can fail or exhibit patterns of failure at the early stages; hence, it is important to understand the early transient behaviour of the leakage currents while the devices are under test. Moreover, during HTRB, a large number of devices are usually stressed and monitored in parallel. In this paper, two 1200 V SiC MOSFETs of similar current ratings (trench and planar) were investigated. Different experiments have been performed to investigate the exponentially decaying transient of the drain-source leakage current, and the differences between monitoring individual discrete devices and monitoring discrete devices grouped together. Experimental results show that when stressing devices in parallel the exponential decay is common to all the devices, with the total current being the result of adding the individual leakage currents. The impact of the stress voltage applied to the devices (700 to 1000 V) and temperature (50 to 150°C) was also investigated. The results show that generally, the transient time is shorter at lower temperatures, and that it increases as the stress voltage increases. Additionally, the investigated devices showed different relaxation time constants in the orders of thousands (trench) and hundreds (planar) of seconds.