Masayuki Nishibata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masayuki Nishibata has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Tomoyuki Kawamata
Department of Anesthesiology, Wakayama Medical University School of Medicine, Wakayama, Japan
2 shared publications- Akari Yoshida
Department of Anesthesiology, Wakayama Medical University, Wakayama City, Japan.
1 shared publication - Hidemasa Furue
Department of Neurophysiology, Hyogo Medical University, Nishinomiya, Japan
1 shared publication Hiroaki Hemmi
Department of Immunology, Institute of Advanced Medicine, Wakayama Medical University School of Medicine, Wakayama 641-8509, Japan
1 shared publicationKeiichi Nagasawa
Department of Anesthesiology, Wakayama Medical University School of Medicine, Wakayama, Japan
1 shared publicationKohtaro Konno
Department of Anatomy, Faculty of Medicine, Hokkaido University, Sapporo 063-8638, Japan
1 shared publication
Latest Publications
- Open Access
- 12 November 2024
- Published by Springer Nature in JA Clinical Reports
- Vol. 10 (1) , 1-4
A rare case of endotracheal tube cuff leakage with no detectable decrease in cuff pressure
Background: Common causes of air leakage around an endotracheal tube include insufficient endotracheal tube cuff inflation and damage to the cuff, while damage to the pilot balloon or pilot balloon tubing is relatively rare. Case presentation: A 74-year-old female with vertebral osteomyelitis was scheduled for an extreme lateral interbody fusion followed posterior fixation. A fiber-optic light was utilized as part of the surgical illuminator. A sudden decrease in tidal volume and airway pressure was noted intraoperatively. We suspected leakage around the endotracheal tube cuff; however, no decrease in cuff pressure was detected. Despite the normal cuff pressure, we decided to inject a small amount of air which led to a significant increase in the cuff pressure. Upon careful inspection of the endotracheal tube, we discovered that the pilot balloon tubing was damaged as a result of thermal energy emitted by the fiber-optic light, which had ignited the surgical drape. The pilot balloon tubing was partially severed in which the section proximal to the endotracheal tube cuff was burned and punctured, causing the cuff leak. Meanwhile, the section proximal to the pilot balloon had melted and occluded the lumen, resulting in a falsely normal cuff pressure reading followed by an elevated cuff pressure when a small amount of air was injected into the pilot balloon during troubleshooting. Appropriate ventilation was resumed after extubation and re-intubation with a new endotracheal tube. Conclusions: We experienced an endotracheal tube cuff leakage caused by a damaged pilot balloon tubing due to thermal energy of the fiber-optic light. Our case report emphasizes the importance of suspecting damage to the endotracheal tube cuff and inflation system despite a normal cuff pressure reading, given that the measurement may be falsely elevated depending on the specific location of the damage. In addition, all operating personnel should be familiarized with safety warnings and cautions related to handling.
- 12 November 2024
- Published by Springer Nature in JA Clinical Reports
- Vol. 10 (1) , 1-4
Open AccessA rare case of endotracheal tube cuff leakage with no detectable decrease in cuff pressure
Background: Common causes of air leakage around an endotracheal tube include insufficient endotracheal tube cuff inflation and damage to the cuff, while damage to the pilot balloon or pilot balloon tubing is relatively rare. Case presentation: A 74-year-old female with vertebral osteomyelitis was scheduled for an extreme lateral interbody fusion followed posterior fixation. A fiber-optic light was utilized as part of the surgical illuminator. A sudden decrease in tidal volume and airway pressure was noted intraoperatively. We suspected leakage around the endotracheal tube cuff; however, no decrease in cuff pressure was detected. Despite the normal cuff pressure, we decided to inject a small amount of air which led to a significant increase in the cuff pressure. Upon careful inspection of the endotracheal tube, we discovered that the pilot balloon tubing was damaged as a result of thermal energy emitted by the fiber-optic light, which had ignited the surgical drape. The pilot balloon tubing was partially severed in which the section proximal to the endotracheal tube cuff was burned and punctured, causing the cuff leak. Meanwhile, the section proximal to the pilot balloon had melted and occluded the lumen, resulting in a falsely normal cuff pressure reading followed by an elevated cuff pressure when a small amount of air was injected into the pilot balloon during troubleshooting. Appropriate ventilation was resumed after extubation and re-intubation with a new endotracheal tube. Conclusions: We experienced an endotracheal tube cuff leakage caused by a damaged pilot balloon tubing due to thermal energy of the fiber-optic light. Our case report emphasizes the importance of suspecting damage to the endotracheal tube cuff and inflation system despite a normal cuff pressure reading, given that the measurement may be falsely elevated depending on the specific location of the damage. In addition, all operating personnel should be familiarized with safety warnings and cautions related to handling.
- Open Access
- 28 December 2023
- Published by Elsevier in Neuroscience
- Vol. 538, 80-92
Activation of Transient Receptor Potential Vanilloid 1 Is Involved in Both Pain and Tumor Growth in a Mouse Model of Cancer Pain
- 28 December 2023
- Published by Elsevier in Neuroscience
- Vol. 538, 80-92
Open AccessActivation of Transient Receptor Potential Vanilloid 1 Is Involved in Both Pain and Tumor Growth in a Mouse Model of Cancer Pain
- Open Access
- 2 November 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (45)
Tmem45b is essential for inflammation- and tissue injury–induced mechanical pain hypersensitivity
Persistent mechanical pain hypersensitivity associated with peripheral inflammation, surgery, trauma, and nerve injury impairs patients’ quality of life and daily activity. However, the molecular mechanism and treatment are not yet fully understood. Herein, we show that chemical ablation of isolectin B4-binding (IB4 + ) afferents by IB4–saporin injection into sciatic nerves completely and selectively inhibited inflammation- and tissue injury–induced mechanical pain hypersensitivity while thermal and mechanical pain hypersensitivities were normal following nerve injury. To determine the molecular mechanism involving the specific types of mechanical pain hypersensitivity, we compared gene expression profiles between IB4 + neuron-ablated and control dorsal root ganglion (DRG) neurons. We identified Tmem45b as one of 12 candidate genes that were specific to somatosensory ganglia and down-regulated by IB4 + neuronal ablation. Indeed, Tmem45b was expressed predominantly in IB4 + DRG neurons, where it was selectively localized in the trans Golgi apparatus of DRG neurons but not detectable in the peripheral and central branches of DRG axons. Tmem45b expression was barely detected in the spinal cord and brain. Although Tmem45b-knockout mice showed normal responses to noxious heat and noxious mechanical stimuli under normal conditions, mechanical pain hypersensitivity was selectively impaired after inflammation and tissue incision, reproducing the pain phenotype of IB4 + sensory neuron-ablated mice. Furthermore, acute knockdown by intrathecal injection of Tmem45b small interfering RNA, either before or after inflammation induction, successfully reduced mechanical pain hypersensitivity. Thus, our study demonstrates that Tmem45b is essential for inflammation- and tissue injury–induced mechanical pain hypersensitivity and highlights Tmem45b as a therapeutic target for future treatment.
- 2 November 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (45)
Open AccessTmem45b is essential for inflammation- and tissue injury–induced mechanical pain hypersensitivity
Persistent mechanical pain hypersensitivity associated with peripheral inflammation, surgery, trauma, and nerve injury impairs patients’ quality of life and daily activity. However, the molecular mechanism and treatment are not yet fully understood. Herein, we show that chemical ablation of isolectin B4-binding (IB4 + ) afferents by IB4–saporin injection into sciatic nerves completely and selectively inhibited inflammation- and tissue injury–induced mechanical pain hypersensitivity while thermal and mechanical pain hypersensitivities were normal following nerve injury. To determine the molecular mechanism involving the specific types of mechanical pain hypersensitivity, we compared gene expression profiles between IB4 + neuron-ablated and control dorsal root ganglion (DRG) neurons. We identified Tmem45b as one of 12 candidate genes that were specific to somatosensory ganglia and down-regulated by IB4 + neuronal ablation. Indeed, Tmem45b was expressed predominantly in IB4 + DRG neurons, where it was selectively localized in the trans Golgi apparatus of DRG neurons but not detectable in the peripheral and central branches of DRG axons. Tmem45b expression was barely detected in the spinal cord and brain. Although Tmem45b-knockout mice showed normal responses to noxious heat and noxious mechanical stimuli under normal conditions, mechanical pain hypersensitivity was selectively impaired after inflammation and tissue incision, reproducing the pain phenotype of IB4 + sensory neuron-ablated mice. Furthermore, acute knockdown by intrathecal injection of Tmem45b small interfering RNA, either before or after inflammation induction, successfully reduced mechanical pain hypersensitivity. Thus, our study demonstrates that Tmem45b is essential for inflammation- and tissue injury–induced mechanical pain hypersensitivity and highlights Tmem45b as a therapeutic target for future treatment.