HTHarutou Tanabe

Harutou Tanabe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Harutou Tanabe has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fluid flow of CO2-driven geyser activity as inferred from tilt and self-potential observations of the Kibedani Geyser Japan

    by Harutou Tanabe, Koki Aizawa, Takeshi Matsushima

    We conducted multi-parameter, multi-site observations at the Kibedani Geyser, Japan, where cold spring-water eruptions (20 °C) are driven by underground CO2 pressure. Observations included video, temperature, self-potential (SP), ground tilt, and acoustic measurements. The geyser exhibits a 38-min cycle, consisting of 32 min between eruptions followed by 6 min of eruption. All data revealed changes corresponding to this cycle. Modeling of tilt data indicate that an inclined crack-shaped cavity pressure source expands between eruptions and contracts during eruption, with post-eruption re-expansion beginning ~ 2.5 min after eruption, when ground tremor has ceased. This cavity is interpreted as a bubble trap where CO2 gas, separated from ascending spring-water, accumulates prior to eruption. SP data modeling suggests that the current source responsible for SP generation, represented by a point and crack-shaped model, is located near this cavity. The correlation between the pressure source and the SP current source suggests that groundwater inflow occurs into the pressure source. Our findings suggest that CO2 accumulates in the cavity, uplifting water during an eruption and driving groundwater inflow into the cavity. This study highlights the effectiveness of combining tilt and SP methods for analyzing fluid-driven phenomena, providing insights into geyser activity and analogous processes such as volcanic phreatic eruptions. We anticipate that our approach, when applied not only to CO2-driven geysers but also to hydrothermal-driven geysers, will contribute to the elucidation of mechanisms underlying phreatic eruptions.

  • Open Access

    Tilt and self-potential observations of Kibedani Geyser, Japan: Relationship between fluid flow and CO2-driven geyser activity

    by Harutou Tanabe, Koki Aizawa, Takeshi Matsushima

    Multi-parameter, multi-site observations were undertaken at the Kibedani Geyser, Japan, where the eruption of cold spring-water (20℃) is driven by underground CO2 pressure. Video, temperature, self-potential (SP), ground tilt, and acoustic observations were undertaken. Tilt and SP data display temporal changes related to the geyser cycle of 38 min (32 min between eruptions, with 6 min of eruption). Tilt data indicate that an inclined crack-shaped cavity pressure source expands between eruptions and contracts during eruption, with post-eruption re-expansion beginning ~2.5 min after eruption, when ground tremor has ceased. SP changes suggest groundwater inflow to the pressure source. We conclude that CO2 accumulates in the cavity, uplifting water for eruption. Tilt and SP multi-site observations were effective in estimating fluid flows associated with geyser activity.

  • Open Access

    Multi-parametric observations of intermittent hydrothermal water discharge in West Crater of Iwo-Yama volcano, Kirishima Volcanic Complex, Japan

    by Harutou Tanabe, Takeshi Matsushima, Koki Aizawa, Dan Muramatsu

    From April to July 2021, West Crater at Iwo-Yama, Kirishima Volcanic Complex, Japan, was repeatedly filled with hydrothermal water and subsequently evacuated. The overall cycle lasted 14–70 h, and the course of a single cycle followed this sequence of phases: (i) steam effusion disappeared 20–40 min before hydrothermal water discharge; (ii) hydrothermal water discharge occurred, generating a hydrothermal water pool; (iii) steam effusion resumed and gradually increased; and (iv) drain-back (evacuation) of the hydrothermal water occurred 1–1.5 h before the onset of the next hydrothermal water discharge. We used multi-parametric observations (optical camera, thermometer, electric self-potential (SP) electrodes, seismometer, acoustic sensor, and tiltmeter) to investigate the cause of the cyclic hydrothermal water discharge. A change in SP data occurred approximately 2 h before the onset of hydrothermal water discharge. However, the change in SP was small when hydrothermal water discharge did not occur. The temporal change in SP is inferred to have been caused by groundwater flow through the region below West Crater, implying that groundwater flow was occurring 2 h before hydrothermal water discharge. The polarity of SP change suggests that groundwater flowed toward the region underlying the vents. Seismic signals in the frequency range of < 20 Hz decreased 15–45 min after the onset of change in SP. This seismic signal pattern is inferred to have been caused by bubble activity in boiling fluid. We interpret that the inflow of cold groundwater inhibited boiling activity in the conduit, which in turn caused the cessation of both steam effusion and seismic activity. SP data suggest that the inflow of cold groundwater gradually decreased before hydrothermal water discharge. Pressurization sufficient to force the water in the upper part of the conduit to ascend could have built up in the lower part of the conduit owing to a decrease in the input of groundwater into the upper part of the conduit and the continuing supply of steam bubbles and hot water. This increase in pressure finally led to hydrothermal water discharge at the surface. We suggest that the inflow of cold groundwater into the geyser conduit was the key control on the occurrence and cyclicity of hydrothermal water discharge in West Crater at Iwo-Yama. Graphical Abstract


  • Open Access

    Multi-parametric observations of intermittent hydrothermal discharge in West Crater of Iwo-Yama volcano, Kirishima Volcanic Complex, Japan

    by Harutou Tanabe, Takeshi Matsushima, Koki Aizawa, Dan Muramatsu

    From April to July 2021, West Crater at Iwo-Yama, Kirishima Volcanic Complex, Japan, was repeatedly filled with hydrothermal water and subsequently evacuated. The overall cycle lasted 14–70 h, and the course of a single cycle followed this sequence of phases: (i) steam effusion disappeared 20–40 min before hydrothermal discharge; (ii) hydrothermal discharge occurred, generating a hydrothermal water pool; (iii) steam effusion resumed and gradually increased; and (iv) drain-back (evacuation) of the hydrothermal water occurred 1–1.5 h before the onset of the next hydrothermal discharge. We used multi-parametric observations (optical camera, thermometer, electric self-potential (SP), seismometer, acoustic sensor, and tiltmeter) to investigate the cause of the cyclic hydrothermal discharge. A change in SP data occurred approximately 2 h before the onset of hydrothermal discharge. However, the change in SP was small when hydrothermal discharge did not occur. The temporal change in SP is inferred to have been caused by groundwater flow through the region below West Crater, implying that groundwater flow was occurring 2 h before hydrothermal discharge. The polarity of SP change suggests that groundwater flowed toward the region underlying the vents. Seismic signals in the frequency range of < 20 Hz decreased 15–45 min after the onset of change in SP. This seismic signal pattern is inferred to have been caused by bubble activity in boiling fluid. We interpret that the inflow of cold groundwater inhibited boiling activity in the conduit, which in turn caused the cessation of both steam effusion and seismic activity. SP data suggest that the inflow of cold groundwater gradually decreased before hydrothermal discharge. Pressurization sufficient to force the water in the upper part of the conduit to ascend could have built up in the lower part of the conduit owing to a decrease in the input of groundwater into the upper part of the conduit and the continuing supply of steam bubbles and hot water. This increase in pressure finally led to hydrothermal discharge at the surface. We suggest that the inflow of cold groundwater into the geyser conduit was the key control on the occurrence and cyclicity of hydrothermal discharge in West Crater at Iwo-Yama.