Jun Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jun Gao has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
Changsheng Cao
Tongji University College of Architecture and Urban Planning
13 shared publicationsLingjie Zeng
12 shared publicationsYunfei Xia
Institute of HVAC, School of Mechanical Engineering, Tongji University, Shanghai, China
5 shared publicationsBowen Du
Univ Toronto, Dept Civil & Mineral Engn, Toronto, ON, Canada
3 shared publicationsChengquan Zhang
Tongji Univ, Coll Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
3 shared publicationsLeqi Tong
Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
3 shared publications
Latest Publications
- 29 October 2026
- Published by Taylor & Francis in Science and Technology for the Built Environment
- p. 1-18
When cooking drives cooling: a simulation study of energy consumption and carbon emissions of electric vs. gas residential kitchens in China
1. China has pledged to peak its carbon emissions by 2030 or earlier (Lin and Guan 2023), making demand-side mitigation in the building sector a national priority. Residential buildings are a signi...
- 29 October 2026
- Published by Taylor & Francis in Science and Technology for the Built Environment
- p. 1-18
When cooking drives cooling: a simulation study of energy consumption and carbon emissions of electric vs. gas residential kitchens in China
1. China has pledged to peak its carbon emissions by 2030 or earlier (Lin and Guan 2023), making demand-side mitigation in the building sector a national priority. Residential buildings are a signi...
- Open Access
- 26 February 2026
- Published by Elsevier in Safety and Health at Work
- Vol. 17 (2) , 206-213
Dryness Response of the Ocular Surface With Use of Wearable Ventilation for Improving Air Quality and Comfort
- 26 February 2026
- Published by Elsevier in Safety and Health at Work
- Vol. 17 (2) , 206-213
Open AccessDryness Response of the Ocular Surface With Use of Wearable Ventilation for Improving Air Quality and Comfort
- 20 November 2025
- Published by Springer Nature in Granular Matter
- Vol. 28 (1) , 5
Experimental and numerical study on dust dispersion characteristics during moving dust source processes
- 20 November 2025
- Published by Springer Nature in Granular Matter
- Vol. 28 (1) , 5
Experimental and numerical study on dust dispersion characteristics during moving dust source processes
- 15 November 2024
- Published by Springer Nature in Building Simulation
- Vol. 17 (12) , 2297-2309
Using the principle of dynamic temporal separation to determine the range hood direct capture efficiency
- 15 November 2024
- Published by Springer Nature in Building Simulation
- Vol. 17 (12) , 2297-2309
Using the principle of dynamic temporal separation to determine the range hood direct capture efficiency
- 24 August 2024
- Published by Elsevier in Building and Environment
- Vol. 265, 111992
Cooking-related thermal comfort and carbon emissions assessment: Comparison between electric and gas cooking in air-conditioned kitchens
- 24 August 2024
- Published by Elsevier in Building and Environment
- Vol. 265, 111992
Cooking-related thermal comfort and carbon emissions assessment: Comparison between electric and gas cooking in air-conditioned kitchens
- 21 May 2024
- Published by Elsevier in Energy and Buildings
- Vol. 315, 114317
Energy savings of commercial kitchen ventilation and air conditioning systems based on cooking oil control and thermal comfort
- 21 May 2024
- Published by Elsevier in Energy and Buildings
- Vol. 315, 114317
Energy savings of commercial kitchen ventilation and air conditioning systems based on cooking oil control and thermal comfort
- 20 August 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 78
Effect of ambient interferences on the effectiveness of a wearable ventilation for reducing pollutant exposure
- 20 August 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 78
Effect of ambient interferences on the effectiveness of a wearable ventilation for reducing pollutant exposure
- Open Access
Study on Temperature Distribution along the Ultra-Long Underwater Tunnel: Based on the Long-Term Measured Results of the Shanghai Yangtze River Tunnel
Tunnels play a vital role in enhancing traffic flow and supporting public transportation systems. However, the discharge of polluted air and waste heat from vehicles passing through tunnels significantly raises the temperature inside, presenting challenges in terms of occupant comfort, tunnel safety, and infrastructure integrity. Therefore, ensuring proper temperature control is essential for their efficient operation. This study aims to investigate the phenomenon of temperature rise in ultra-long tunnels during normal operations, as limited research has been conducted in this area. The Shanghai Yangtze River Tunnel serves as a case study, utilizing temperature and air velocity data collected throughout the year (2021) from the management company. The analysis reveals that the temperature distribution near the tunnel exit is influenced by outdoor temperature fluctuations and traffic volume. The highest temperatures occur on 25 August (39.74 °C) during peak traffic hours. On-site measurements of tunnel temperature, humidity, and air velocity during winter and summer seasons yield the following results. During winter, the air temperature and wall temperature inside the tunnel experience significant increases along its length. The air temperature rises by approximately 11 °C from the entrance to the exit, while the wall temperature increases by about 15 °C. In contrast, during summer, the air temperature only rises by 2.7 °C, and the wall temperature increases by around 3 °C. Consequently, the humidity decreases along the tunnel, and this decrease is correlated with the magnitude of temperature increase. Furthermore, measurements of air velocity indicate that natural and traffic-induced winds contribute to the overall airflow inside the tunnel. A temperature data logger installed in the tunnel recorded temperature changes during the period of pandemic lockdown and subsequent recovery, spanning the spring and summer seasons. During the lockdown period, there was a relatively small increase in temperature along the tunnel, suggesting that vehicle heat dissipation is the primary factor contributing to temperature rise inside. Additionally, a method is proposed to predict the cross-sectional temperature of the tunnel using measured air velocities.
Open AccessStudy on Temperature Distribution along the Ultra-Long Underwater Tunnel: Based on the Long-Term Measured Results of the Shanghai Yangtze River Tunnel
Tunnels play a vital role in enhancing traffic flow and supporting public transportation systems. However, the discharge of polluted air and waste heat from vehicles passing through tunnels significantly raises the temperature inside, presenting challenges in terms of occupant comfort, tunnel safety, and infrastructure integrity. Therefore, ensuring proper temperature control is essential for their efficient operation. This study aims to investigate the phenomenon of temperature rise in ultra-long tunnels during normal operations, as limited research has been conducted in this area. The Shanghai Yangtze River Tunnel serves as a case study, utilizing temperature and air velocity data collected throughout the year (2021) from the management company. The analysis reveals that the temperature distribution near the tunnel exit is influenced by outdoor temperature fluctuations and traffic volume. The highest temperatures occur on 25 August (39.74 °C) during peak traffic hours. On-site measurements of tunnel temperature, humidity, and air velocity during winter and summer seasons yield the following results. During winter, the air temperature and wall temperature inside the tunnel experience significant increases along its length. The air temperature rises by approximately 11 °C from the entrance to the exit, while the wall temperature increases by about 15 °C. In contrast, during summer, the air temperature only rises by 2.7 °C, and the wall temperature increases by around 3 °C. Consequently, the humidity decreases along the tunnel, and this decrease is correlated with the magnitude of temperature increase. Furthermore, measurements of air velocity indicate that natural and traffic-induced winds contribute to the overall airflow inside the tunnel. A temperature data logger installed in the tunnel recorded temperature changes during the period of pandemic lockdown and subsequent recovery, spanning the spring and summer seasons. During the lockdown period, there was a relatively small increase in temperature along the tunnel, suggesting that vehicle heat dissipation is the primary factor contributing to temperature rise inside. Additionally, a method is proposed to predict the cross-sectional temperature of the tunnel using measured air velocities.
- Open Access
- 3 July 2023
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 15 (7)
Noise level effect on the hypersonic boundary layer
The boundary layer state has a critical effect on hypersonic vehicle performance and the noise level is the main factor causing the differences between the boundary layer transition in a wind tunnel test and that in a real flight. The second mode wave frequency of the 7° half-angle cone models as measured in four hypersonic wind tunnels is collected. The effects of the noise level on the boundary layer are determined by comparing dimensionless parameters, which are nondimensionalized based on computed values. The results indicate that the noise level could affect the second mode wave frequency and the boundary layer thickness, where the second mode wave frequency decreases and the boundary layer thickness increases with increasing noise level. However, the mechanism by which the noise level influences the second mode wave frequency and the boundary layer thickness requires further study.
- 3 July 2023
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 15 (7)
Open AccessNoise level effect on the hypersonic boundary layer
The boundary layer state has a critical effect on hypersonic vehicle performance and the noise level is the main factor causing the differences between the boundary layer transition in a wind tunnel test and that in a real flight. The second mode wave frequency of the 7° half-angle cone models as measured in four hypersonic wind tunnels is collected. The effects of the noise level on the boundary layer are determined by comparing dimensionless parameters, which are nondimensionalized based on computed values. The results indicate that the noise level could affect the second mode wave frequency and the boundary layer thickness, where the second mode wave frequency decreases and the boundary layer thickness increases with increasing noise level. However, the mechanism by which the noise level influences the second mode wave frequency and the boundary layer thickness requires further study.
- 3 November 2022
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 44 (1) , 63-79
Prediction of mould growth rate within building envelopes: development and validation of an improved model
Mould growth is a common problem in building envelopes. This issue is usually caused by poor design and construction of walls and results from the difference between indoor and outdoor climatic conditions. Mould spores produced by mouldy walls may diffuse into the air, thereby affecting indoor air quality and threatening occupant health. Therefore, it is important to predict the risk of mould growth in building envelopes under various conditions. This study selected three buildings from a traditional community in Shanghai, China. First, the mould species in these building envelopes were identified. Based on the identification results, the growth rate of the corresponding genera was extracted from the literature to establish an isoline model that describes mould growth on the agar surface. In addition, the mould growth rate between and outside the isoline areas was predicted by modifying the Sautour model to relevant air temperature and humidity conditions. According to the results of the proposed model, the critical temperature and humidity that allow the growth of representative moulds from the buildings selected for this study can be expressed as φ =0.002633·cosh[0.10083·( θ -30)]+0.7153. The accuracy of the above model was verified experimentally, and the maximum relative error of the growth rate was within 25%.
- 3 November 2022
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 44 (1) , 63-79
Prediction of mould growth rate within building envelopes: development and validation of an improved model
Mould growth is a common problem in building envelopes. This issue is usually caused by poor design and construction of walls and results from the difference between indoor and outdoor climatic conditions. Mould spores produced by mouldy walls may diffuse into the air, thereby affecting indoor air quality and threatening occupant health. Therefore, it is important to predict the risk of mould growth in building envelopes under various conditions. This study selected three buildings from a traditional community in Shanghai, China. First, the mould species in these building envelopes were identified. Based on the identification results, the growth rate of the corresponding genera was extracted from the literature to establish an isoline model that describes mould growth on the agar surface. In addition, the mould growth rate between and outside the isoline areas was predicted by modifying the Sautour model to relevant air temperature and humidity conditions. According to the results of the proposed model, the critical temperature and humidity that allow the growth of representative moulds from the buildings selected for this study can be expressed as φ =0.002633·cosh[0.10083·( θ -30)]+0.7153. The accuracy of the above model was verified experimentally, and the maximum relative error of the growth rate was within 25%.