Viet Minh Trinh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Viet Minh Trinh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Minh Tuan Nguyen
Institute of Environmental Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Hanoi 100000, Viet Nam
3 shared publications - Phuong Thao Nguyen
Institute of Environmental Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Ha Noi, Viet Nam
3 shared publications - Trinh Van Tuyen
Institute of Environmental Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Ha Noi, Viet Nam
3 shared publications - Huu Tung Pham
Institute of Environmental Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, Ha Noi, Viet Nam
2 shared publications - Van Manh Do
Institute of Science and Technology for Energy and Environment, Vietnam Academy of Science and Technology, Hanoi, Vietnam
2 shared publications - Channarong Asavatesanupap
Department of Mechanical Engineering, Faculty of Engineering, Thammasat School of Engineering
1 shared publication
Latest Publications
- Open Access
- 18 September 2024
- Published by MDPI AG in Environments
- Vol. 11 (9) , 206
Steam Stripping for Recovery of Ammonia from Wastewater Using a High-Gravity Rotating Packed Bed
Steam stripping of ammonia from ammonia-rich wastewater (5000–20,000 mg/L) was conducted in a continuous-flow rotating packed bed (RPB) at a pH of 11. This study aimed to elucidate the influence of key operational parameters, including the steam-to-liquid ratio, rotational speed (ω), initial ammonia concentration, steam inlet temperature (TSi), and liquid inlet temperature (TLi), on critical performance metrics such as the ammonia removal efficiency (ARE), the volumetric liquid mass transfer coefficient (KLa), and the concentration of the recovered ammonia solution (CR). The findings revealed that a CR of 22.88 wt.% was achieved under the optimal conditions of a steam-to-liquid ratio of 0.175 kg/kg, an initial concentration of 20,000 mg/L, a TSi of 120 °C, and a TLi of 70 °C. Key experimental factors, including the initial ammonia concentration, TSi, and TLi, significantly impacted the achievement of higher ARE and CR values. The KLa values exhibited a decrease with the increase in the steam-to-liquid ratio, while they increased with ω. However, the KLa remained relatively consistent with ω values within the range of 600 to 1200 rpm. In comparison with prior studies, steam stripping of ammonia exhibits a higher ARE than air stripping with RPB and a higher CR than conventional stripping methods. Moreover, RPB requires a smaller size to achieve equivalent ARE compared to conventional stripping apparatuses. Thus, the steam stripping process with RPB equipment emerges as a suitable method for ammonia recovery from ammonia-rich wastewater.
- 18 September 2024
- Published by MDPI AG in Environments
- Vol. 11 (9) , 206
Open AccessSteam Stripping for Recovery of Ammonia from Wastewater Using a High-Gravity Rotating Packed Bed
Steam stripping of ammonia from ammonia-rich wastewater (5000–20,000 mg/L) was conducted in a continuous-flow rotating packed bed (RPB) at a pH of 11. This study aimed to elucidate the influence of key operational parameters, including the steam-to-liquid ratio, rotational speed (ω), initial ammonia concentration, steam inlet temperature (TSi), and liquid inlet temperature (TLi), on critical performance metrics such as the ammonia removal efficiency (ARE), the volumetric liquid mass transfer coefficient (KLa), and the concentration of the recovered ammonia solution (CR). The findings revealed that a CR of 22.88 wt.% was achieved under the optimal conditions of a steam-to-liquid ratio of 0.175 kg/kg, an initial concentration of 20,000 mg/L, a TSi of 120 °C, and a TLi of 70 °C. Key experimental factors, including the initial ammonia concentration, TSi, and TLi, significantly impacted the achievement of higher ARE and CR values. The KLa values exhibited a decrease with the increase in the steam-to-liquid ratio, while they increased with ω. However, the KLa remained relatively consistent with ω values within the range of 600 to 1200 rpm. In comparison with prior studies, steam stripping of ammonia exhibits a higher ARE than air stripping with RPB and a higher CR than conventional stripping methods. Moreover, RPB requires a smaller size to achieve equivalent ARE compared to conventional stripping apparatuses. Thus, the steam stripping process with RPB equipment emerges as a suitable method for ammonia recovery from ammonia-rich wastewater.
- Open Access
- 16 August 2024
- Published by Publishing House for Science and Technology, Vietnam Academy of Science and Technology (Publications) in Vietnam Journal of Science and Technology
- Vol. 62 (4) , 775-786
Ammonia removal from digested swine wastewater using a High-Performance Rotating Reactor
The wastewater generated from the livestock industry is an enormous source of pollution that is challenging the sustainable development of the agricultural sector. Even the anaerobic digestion is adopted, the characteristic of the digested wastewater is still way polluted compared to the discharge standard. The high content of ammonia in this wastewater resulted in a low C/N ratio, consequently inhibiting the aerobic biological treatment. Hence, it is necessary to pretreat the excessive concentration of ammonia from the input stream of livestock wastewater. The High-Performance Rotating Reactor (HP2R) equipment has been proven to be a promising and advanced equipment to remove high concentrations of ammonia from synthetic wastewater via stripping. Therefore, ammonia removal using HP2R equipment was comprehensively studied with the digested swine wastewater under various operational conditions. In this study, the effects of pre-alkalinization (pHi), rotating speed (ω), gas flow rate (QG), and swine wastewater flow rate (QL) on the ammonia removal efficiency (ARE) and the overall liquid mass transfer coefficient (KLa) was evaluated. The results indicated that the HP2R could effectively remove ammonia from the wastewater in instant batch mode at a laboratory scale. The ARE by stripping via HP2R varied from 33% to 78% at various gas and liquid flow rate with the pre-alkalinization of swine wastewater pHi of 11, ω of 900-1200 rpm, and the initial ammonia concentration of approximately 660 mg/L. Especially, the mass transfer of the process was enhanced compared to the conventional packed column as the KLa varied from 0.0014 s-1 to 0.0038 s-1.
- 16 August 2024
- Published by Publishing House for Science and Technology, Vietnam Academy of Science and Technology (Publications) in Vietnam Journal of Science and Technology
- Vol. 62 (4) , 775-786
Open AccessAmmonia removal from digested swine wastewater using a High-Performance Rotating Reactor
The wastewater generated from the livestock industry is an enormous source of pollution that is challenging the sustainable development of the agricultural sector. Even the anaerobic digestion is adopted, the characteristic of the digested wastewater is still way polluted compared to the discharge standard. The high content of ammonia in this wastewater resulted in a low C/N ratio, consequently inhibiting the aerobic biological treatment. Hence, it is necessary to pretreat the excessive concentration of ammonia from the input stream of livestock wastewater. The High-Performance Rotating Reactor (HP2R) equipment has been proven to be a promising and advanced equipment to remove high concentrations of ammonia from synthetic wastewater via stripping. Therefore, ammonia removal using HP2R equipment was comprehensively studied with the digested swine wastewater under various operational conditions. In this study, the effects of pre-alkalinization (pHi), rotating speed (ω), gas flow rate (QG), and swine wastewater flow rate (QL) on the ammonia removal efficiency (ARE) and the overall liquid mass transfer coefficient (KLa) was evaluated. The results indicated that the HP2R could effectively remove ammonia from the wastewater in instant batch mode at a laboratory scale. The ARE by stripping via HP2R varied from 33% to 78% at various gas and liquid flow rate with the pre-alkalinization of swine wastewater pHi of 11, ω of 900-1200 rpm, and the initial ammonia concentration of approximately 660 mg/L. Especially, the mass transfer of the process was enhanced compared to the conventional packed column as the KLa varied from 0.0014 s-1 to 0.0038 s-1.
- Open Access
- 2 August 2023
- Published by Publishing House for Science and Technology, Vietnam Academy of Science and Technology (Publications) in Vietnam Journal of Science and Technology
- p. 609-619
Study on recycle of granulated blast-furnace slag as an adsorbent for ammonium remediation in wastewater
Blast-furnace slag (BFS) is enormously generated each year and has been considered as hazardous solid waste which is posing a significant pressure on waste treatment in terms of storage and transportation. This study aims to recycle BFS as a material for ammonium adsorption from an aqueous solution. Natural-state BFS and acidic-modified by using HNO3 at various concentration of 0.5M, 1M, and 3M (A-BFS1, A-BFS2, and A-BFS3) was examined. The surface characteristics of the materials were examined by BET analysis and Scanning Electron Microscope. The adsorption of ammonium on the BFS materials was conducted in batch mode at various conditions of contact time, pH level, adsorbent dosage, and initial concentration of ammonium. The results indicated that the HNO3 modification exhibited pore creations and surface enhancement as the A-BFS3 has 25.7 times larger surface area and 10.3 times pore size improvement. The A-BFS3 showed good ammonium adsorption capacity compared to other materials, which is 1.81 mg/g at the optimum conditions of pH 6, contact time of 120 minutes, and dosage of 0.5 g in 50 mL of 20 mg/L ammonium solution. Langmuir and Freundlich adsorption isotherm models of the A-BFS3 material showed a relatively good correlation with R2 values of 0.999 and 0.9625, respectively.
- 2 August 2023
- Published by Publishing House for Science and Technology, Vietnam Academy of Science and Technology (Publications) in Vietnam Journal of Science and Technology
- p. 609-619
Open AccessStudy on recycle of granulated blast-furnace slag as an adsorbent for ammonium remediation in wastewater
Blast-furnace slag (BFS) is enormously generated each year and has been considered as hazardous solid waste which is posing a significant pressure on waste treatment in terms of storage and transportation. This study aims to recycle BFS as a material for ammonium adsorption from an aqueous solution. Natural-state BFS and acidic-modified by using HNO3 at various concentration of 0.5M, 1M, and 3M (A-BFS1, A-BFS2, and A-BFS3) was examined. The surface characteristics of the materials were examined by BET analysis and Scanning Electron Microscope. The adsorption of ammonium on the BFS materials was conducted in batch mode at various conditions of contact time, pH level, adsorbent dosage, and initial concentration of ammonium. The results indicated that the HNO3 modification exhibited pore creations and surface enhancement as the A-BFS3 has 25.7 times larger surface area and 10.3 times pore size improvement. The A-BFS3 showed good ammonium adsorption capacity compared to other materials, which is 1.81 mg/g at the optimum conditions of pH 6, contact time of 120 minutes, and dosage of 0.5 g in 50 mL of 20 mg/L ammonium solution. Langmuir and Freundlich adsorption isotherm models of the A-BFS3 material showed a relatively good correlation with R2 values of 0.999 and 0.9625, respectively.
- Open Access
Removal of Nutrients and COD in Wastewater from Vietnamese Piggery Farm by the Culture of Chlorella vulgaris in a Pilot-Scaled Membrane Photobioreactor
The treatment of nutrients and organic contaminants in wastewater using microalgae has drawn significant interest thanks to its advantages of environmental friendliness, low cost, CO2 emission reduction, and recycling of valuable biomass. Among other algae species, Chlorella sp. showed good vitality, simplicity in cultivation, and high nutrient accumulation in harsh conditions of wastewater. In this study, Chlorella vulgaris was inoculated in a membrane photobioreactor (MPBR) with piggery digestate to investigate the C. vulgaris growth rate and the removal efficiency of nutrients and chemical oxygen demand (COD). The results indicated that the cultivation of C. vulgaris in an MPBR system exhibited continuous and simultaneous removal of NH4+, PO43−, and COD from two-fold diluted piggery wastewater. Both the algae growth rate and nutrient removal depended on the liquid hydraulic retention time in the MPBR. The highest removal efficiency of NH4+ (74.55%), PO43− (70.20%), and COD (65.85%) was obtained in the longest HRT of 5 days with the highest microalgae biomass concentration of around 1.1 g/L. The algae washout phenomenon was negligible in the continuous cultivation in the MPBR system. Compared to the cultivation in batch mode, the MPBR could achieve a similar algae growth rate and treatment efficiency with a much shorter hydraulic retention time.
Open AccessRemoval of Nutrients and COD in Wastewater from Vietnamese Piggery Farm by the Culture of Chlorella vulgaris in a Pilot-Scaled Membrane Photobioreactor
The treatment of nutrients and organic contaminants in wastewater using microalgae has drawn significant interest thanks to its advantages of environmental friendliness, low cost, CO2 emission reduction, and recycling of valuable biomass. Among other algae species, Chlorella sp. showed good vitality, simplicity in cultivation, and high nutrient accumulation in harsh conditions of wastewater. In this study, Chlorella vulgaris was inoculated in a membrane photobioreactor (MPBR) with piggery digestate to investigate the C. vulgaris growth rate and the removal efficiency of nutrients and chemical oxygen demand (COD). The results indicated that the cultivation of C. vulgaris in an MPBR system exhibited continuous and simultaneous removal of NH4+, PO43−, and COD from two-fold diluted piggery wastewater. Both the algae growth rate and nutrient removal depended on the liquid hydraulic retention time in the MPBR. The highest removal efficiency of NH4+ (74.55%), PO43− (70.20%), and COD (65.85%) was obtained in the longest HRT of 5 days with the highest microalgae biomass concentration of around 1.1 g/L. The algae washout phenomenon was negligible in the continuous cultivation in the MPBR system. Compared to the cultivation in batch mode, the MPBR could achieve a similar algae growth rate and treatment efficiency with a much shorter hydraulic retention time.
- Open Access
- 31 August 2022
- Published by Publishing House for Science and Technology, Vietnam Academy of Science and Technology (Publications) in Vietnam Journal of Science and Technology
- Vol. 60 (4) , 675-690
Study on the recycle of steel slag as an adsorbent for COD removal in pulp mill wastewater
This study aims to characterize and investigate steel slag for the removal of its persistent organic pollutants (measured as COD) from pulp mill wastewater. Steel slag and its NaOH-modified states were characterized by Fourier-transform infrared spectroscopy (FT-IR), Brunauer-Emmett-Teller (BET) surface area analysis, Barrett-Joyner-Halenda (BJH) pore size, and volume analysis. Batch adsorption experiments were conducted to investigate the COD adsorption of slag-based adsorbents. The modification of NaOH was found to improve the COD adsorption capacity (by 1.5 times) of steel slag by generating hydroxyl and carboxyl groups and enlarging the specific surface area and pore size in the steel slag particles. In batch experiments, the suitable conditions for COD adsorption on NS (steel slag) and MS20 (2 M NaOH-modified steel slag) were determined to be pH 6 - 8, contact time 90 minutes, and adsorbent dosage 20 g/L. Langmuir and Freundlich adsorption isotherm models satisfactorily described the adsorption of COD on both NS and MS20 with a good correlation. According to the Langmuir isotherm, the maximum COD adsorption capacity of NS and MS20 were 5.16 and 6.87 mg/g, respectively. Column experiments demonstrated that NS and MS20 had promising potential for COD treatment in pulp mill effluent. According to the column results, 20 g of NS or MS20 was able to keep 300 mL or 525 mL of 125 mg/L COD wastewater, respectively, reaching the threshold of the National Technical Regulation on Industrial Wastewater QCVN 40:2021/BTNMT.
- 31 August 2022
- Published by Publishing House for Science and Technology, Vietnam Academy of Science and Technology (Publications) in Vietnam Journal of Science and Technology
- Vol. 60 (4) , 675-690
Open AccessStudy on the recycle of steel slag as an adsorbent for COD removal in pulp mill wastewater
This study aims to characterize and investigate steel slag for the removal of its persistent organic pollutants (measured as COD) from pulp mill wastewater. Steel slag and its NaOH-modified states were characterized by Fourier-transform infrared spectroscopy (FT-IR), Brunauer-Emmett-Teller (BET) surface area analysis, Barrett-Joyner-Halenda (BJH) pore size, and volume analysis. Batch adsorption experiments were conducted to investigate the COD adsorption of slag-based adsorbents. The modification of NaOH was found to improve the COD adsorption capacity (by 1.5 times) of steel slag by generating hydroxyl and carboxyl groups and enlarging the specific surface area and pore size in the steel slag particles. In batch experiments, the suitable conditions for COD adsorption on NS (steel slag) and MS20 (2 M NaOH-modified steel slag) were determined to be pH 6 - 8, contact time 90 minutes, and adsorbent dosage 20 g/L. Langmuir and Freundlich adsorption isotherm models satisfactorily described the adsorption of COD on both NS and MS20 with a good correlation. According to the Langmuir isotherm, the maximum COD adsorption capacity of NS and MS20 were 5.16 and 6.87 mg/g, respectively. Column experiments demonstrated that NS and MS20 had promising potential for COD treatment in pulp mill effluent. According to the column results, 20 g of NS or MS20 was able to keep 300 mL or 525 mL of 125 mg/L COD wastewater, respectively, reaching the threshold of the National Technical Regulation on Industrial Wastewater QCVN 40:2021/BTNMT.