JPJulio Plaza

Julio Plaza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julio Plaza has a total of 298 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Neutron elastic scattering at $\varvec{30.8}$ MeV on $\varvec{^{\text {nat}}\textrm{Ce}}$

    by P. Miriot-Jaubert, M. Vandebrouck, I. Matea, D. Doré, M. Dupuis, X. Ledoux, T. Martinez, A. Pérez de Rada Fiol, S. Péru, N. L. Achouri, et al.

    Elastic scattering of fast neutrons at an incident energy of 30.8 MeV on a natural cerium target was measured during an experiment conducted at the Neutrons For Science facility at GANIL-SPIRAL2. This is the first measurement on cerium using incident neutron energy above 20 MeV. The differential cross-section up to 40 $$^\circ $$ ∘ in the centre-of-mass frame was extracted using the MONSTER liquid scintillator array for the scattered neutron detection. The experimental results are compared to global optical-model calculations, providing an overall very good agreement and a useful benchmark at intermediate energy.

  • Environmental γ -ray flux in Hall C at LNGS and its correlation with radon activity

    by L. Luzzi, R. Santorelli, G. Zuzel, P. Agnes, D. Cano-Ott, C. Ghiano, M. Laubenstein, T. Mroz, V. Pesudo Fortes, J. Plaza del Olmo, et al.

    We report a comprehensive measurement of the environmental $\ensuremath{\gamma}$-ray flux in Hall C of the Gran Sasso National Laboratory. A spatial mapping of the radiation was carried out using a high-purity germanium detector mounted on a movable cart and deployed at eight locations within the hall. The detector response function and full-energy-peak efficiencies were determined through Geant4 simulations validated with calibrated $\ensuremath{\gamma}$-ray sources, with particular attention devoted to the efficiency modeling and associated systematic uncertainties. In the energy range of 57--2800 keV, the average $\ensuremath{\gamma}$-ray flux is measured to be ($0.46\ifmmode\pm\else\textpm\fi{}0.0{6}_{\mathrm{stat}}\ifmmode\pm\else\textpm\fi{}0.0{3}_{\mathrm{syst}}$) ${\mathrm{cm}}^{\ensuremath{-}2}\text{ }{\mathrm{s}}^{\ensuremath{-}1}$. The radon level was monitored for about a month using a radon detector mounted on the same cart, and a clear correlation is observed between the environmental $\ensuremath{\gamma}$-ray rate and the ambient radon concentration, consistent with the short-lived daughters of $^{222}\mathrm{Rn}$. This result represents the first high-precision and efficiency-corrected mapping of the $\ensuremath{\gamma}$-ray flux in Hall C, substantially improving its radiological characterization and providing key input for future rare-event experiments operating in this hall.

  • Open Access

    First Results of the 64Ni(n,γ) Cross Section Measurement at n_TOF

    by Michele Spelta, Gabriele Cescutti, Sergio Cristallo, Francisco García-Infantes, Alice Manna, Alberto Mengoni, Paolo Maria Milazzo, Riccardo Mucciola, Giuseppe Tagliente, Diego Vescovi, et al.

    The neutron capture cross section of 64Ni is an important parameter in nuclear astrophysics that is needed to accurately simulate stellar nucleosynthesis and validate stellar models. 64Ni is among the seeds of the s-process and its capture cross section has been found to have an important effect on the predicted abundances of many nuclei synthesized in Asymptotic Giant Branch (AGB) and massive stars. Despite its relevance, the measurements of the 64Ni(n,γ) available in the literature are scarce and discrepant. For this reason, a new accurate time-of-flight measurement has been performed at the n_TOF facility at CERN, taking advantage of its high instantaneous neutron flux, and using a highly enriched 64Ni sample. The first preliminary results show important discrepancies with respect to the cross sections recommended in the most recent releases of the evaluated nuclear data libraries. In particular, a large resonance reported at 9.52 keV is not observed. As a consequence, a significant reduction in the Maxwellian-Averaged Cross Section (MACS) obtained from evaluated data libraries in the 5–25 keV thermal energy region is expected.

  • Open Access

    β -delayed neutron spectroscopy of As85,86 with MONSTER at IGISOL

    by A. Pérez de Rada Fiol, T. Martínez, D. Cano-Ott, H. Penttilä, J. Agramunt, V. Alcayne, A. Algora, S. Alhomaidhi, J. Äystö, K. Banerjee, et al.

    The β -delayed neutron emission in the As 85 , 86 β decays has been measured at the Ion Guide Isotope Separator On Line facility of the Accelerator Laboratory of the University of Jyväskylä. The complete β decays have been studied with a complex setup that consists of a plastic scintillator for β particles, MONSTER—the MOdular Neutron time-of-flight SpectromeTER—for neutrons, and a high-purity germanium and four LaBr 3 crystals for γ rays. The β -delayed neutron energy distributions have been determined by unfolding the time-of-flight spectra with an innovative methodology based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. The results obtained for As 85 are in excellent agreement with the existing evaluated data, validating the proposed methodology. In the case of As 86 , a stronger neutron intensity at higher energies than previously predicted is discovered.


  • Open Access

    Hardware Acceleration of Digital Pulse Shape Analysis Using FPGAs

    by César González, Mariano Ruiz, Antonio Carpeño, Alejandro Piñas, Daniel Cano-Ott, Julio Plaza, Trino Martinez, David Villamarin

    The BC501A sensor is a liquid scintillator frequently used in nuclear physics for detecting fast neutrons. This paper describes a hardware implementation of digital pulse shape analysis (DPSA) for real-time analysis. DPSA is an algorithm that extracts the physically relevant parameters from the detected BC501A signals. The hardware solution is implemented in a MicroTCA system that provides the physical, mechanical, electrical, and cooling support for an AMC board (NAMC-ZYNQ-FMC) with a Xilinx ZYNQ Ultrascale-MP SoC. The Xilinx FPGA programmable logic implements a JESD204B interface to high-speed ADCs. The physical and datalink JESD204B layers are implemented using hardware description language (HDL), while the Xilinx high-level synthesis language (HLS) is used for the transport and application layers. The DPSA algorithm is a JESD204B application layer that includes a FIR filter and a constant fraction discriminator (CFD) function, a baseline calculation function, a peak detection function, and an energy calculation function. This architecture achieves an analysis mean time of less than 100 µs per signal with an FPGA resource utilization of about 50% of its most used resources. This paper presents a high-performance DPSA embedded system that interfaces with a 1 GS/s ADC and performs accurate calculations with relatively low latency.


  • Open Access

    CLYC as a neutron detector in low background conditions

    by J. Plaza, V. Bécares, D. Cano-Ott, C. Gómez, T. Martínez, E. Mendoza, A. Pérez de Rada, V. Pesudo, J. C. Sáez-Vergara, R. Santorelli, et al.

    We report on the thermal neutron flux measurements carried out at the Laboratorio Subterráneo de Canfranc (LSC) with two commercial $$2^{\prime \prime } \times 2^{\prime \prime }$$ 2 ″ × 2 ″ CLYC detectors. The measurements were performed as part of an experimental campaign at LSC with $$^{3}$$ 3 He detectors, for establishing the sensitivity limits and use of CLYCs in low background conditions. A careful characterization of the intrinsic $$\alpha $$ α and $$\gamma $$ γ -ray background in the detectors was required and done with dedicated measurements. It was found that the $$\alpha $$ α activities in the two CLYC crystals differ by a factor of three, and the use of Monte Carlo simulations and a Bayesian unfolding method allowed us to determine the specific $$\alpha $$ α activities from the $$^{238}$$ 238 U and $$^{232}$$ 232 Th decay chains. The simulations and unfolding also revealed that the $$\gamma $$ γ -ray background registered in the detectors is dominated by the intrinsic activity of the components of the detector such as the aluminum housing and photo-multiplier and that the activity within the crystal is low in comparison. The data from the neutron flux measurements with the two detectors were analyzed with different methodologies: one based on an innovative $$\alpha $$ α /neutron pulse shape discrimination method and one based on the subtraction of the intrinsic $$\alpha $$ α background that masks the neutron signals in the region of interest. The neutron sensitivity of the CLYCs was calculated by Monte Carlo simulations with MCNP6 and GEANT4. The resulting thermal neutron fluxes are in good agreement with complementary flux measurement performed with $$^{3}$$ 3 He detectors, but close to the detection limit imposed by the intrinsic $$\alpha $$ α activity.


  • Open Access

    Thermal neutron background at Laboratorio Subterráneo de Canfranc (LSC)

    by J. Plaza, T. Martínez, V. Bécares, D. Cano-Ott, D. Villamarín, A. Pérez de Rada, E. Mendoza, V. Pesudo, R. Santorelli, C. Peña, et al.


  • Monolithic integration of uncooled PbSe bicolor detectors

    by M.C. Torquemada, V. Villamayor, L.J. Gómez, G. Vergara, M.T. Rodrigo, G. Pérez, I. Génova, I. Catalán, D. Fernández, R.M. Almazán, et al.