AKAtilla Peter Kiraly

Atilla Peter Kiraly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Atilla Peter Kiraly has a total of 181 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An open vision-language model for diverse medical applications

    by Andrew Sellergren, Sahar Kazemzadeh, Fereshteh Mahvar, Atilla Kiraly, Madeleine Traverse, Timo Kohlberger, Chufan Gao, Ronnachai Jaroensri, Shawn Xu, Fayaz Jamil, et al.

    Artificial intelligence has high potential for impact in healthcare applications, but its training and deployment are challenging due to diverse data, a complex spectrum of possible tasks and important privacy needs. High-performing foundation models that enable data-efficient fine-tuning for diverse downstream tasks can meaningfully accelerate development in this domain. We introduce MedGemma, a collection of medical vision-language foundation models based on Gemma 3. MedGemma demonstrates advanced medical understanding and reasoning across images and text and multiple medical imaging domains, exceeding the performance of similarly sized generative models while maintaining the general capabilities of the Gemma base models. For out-of-distribution tasks, MedGemma achieves improvements of 2.6–10% in medical image question answering, 15.5–18.1% in chest X-ray finding classification and 10.8% in agentic evaluations compared with the base models. Our results show that fine-tuning MedGemma can be more effective than fine-tuning the base Gemma 3 model for medical tasks, particularly in the setting of limited training data. We additionally introduce MedSigLIP, a medically tuned vision encoder derived from SigLIP. MedSigLIP powers the visual understanding capabilities of MedGemma and, as an encoder, achieves performance comparable to or better than that of many specialized medical image encoders. Taken together, the MedGemma collection provides a strong foundation of medical image and text capabilities, with the potential to accelerate medical research and the development of downstream applications.


  • Open Access

    Triaging mammography with artificial intelligence: an implementation study

    by Sarah M. Friedewald, Marcin Sieniek, Sunny Jansen, Fereshteh Mahvar, Timo Kohlberger, David Schacht, Sonya Bhole, Dipti Gupta, Shruthi Prabhakara, Scott Mayer McKinney, et al.

    Purpose Many breast centers are unable to provide immediate results at the time of screening mammography which results in delayed patient care. Implementing artificial intelligence (AI) could identify patients who may have breast cancer and accelerate the time to diagnostic imaging and biopsy diagnosis. Methods In this prospective randomized, unblinded, controlled implementation study we enrolled 1000 screening participants between March 2021 and May 2022. The experimental group used an AI system to prioritize a subset of cases for same-visit radiologist evaluation, and same-visit diagnostic workup if necessary. The control group followed the standard of care. The primary operational endpoints were time to additional imaging (TA) and time to biopsy diagnosis (TB). Results The final cohort included 463 experimental and 392 control participants. The one-sided Mann-Whitney U test was employed for analysis of TA and TB. In the control group, the TA was 25.6 days [95% CI 22.0–29.9] and TB was 55.9 days [95% CI 45.5–69.6]. In comparison, the experimental group's mean TA was reduced by 25% (6.4 fewer days [one-sided 95% CI > 0.3], p 5.1], p=0.003). The time reduction was more pronounced for AI-prioritized participants in the experimental group. All participants eventually diagnosed with breast cancer were prioritized by the AI. Conclusions Implementing AI prioritization can accelerate care timelines for patients requiring additional workup, while maintaining the efficiency of delayed interpretation for most participants. Reducing diagnostic delays could contribute to improved patient adherence, decreased anxiety and addressing disparities in access to timely care.


  • Open Access

    Prospective Multi-Site Validation of AI to Detect Tuberculosis and Chest X-Ray Abnormalities

    by Sahar Kazemzadeh, Atilla P. Kiraly, Zaid Nabulsi, Nsala Sanjase, Minyoi Maimbolwa, Brian Shuma, Shahar Jamshy, Christina Chen, Arnav Agharwal, Charles T. Lau, et al.

    Using artificial intelligence (AI) to interpret chest X-rays (CXRs) could support accessible triage tests for active pulmonary tuberculosis (TB) in resource-constrained settings. The performance of two cloud-based CXR AI systems — one to detect TB and the other to detect CXR abnormalities — in a population with a high TB and human immunodeficiency virus (HIV) burden was evaluated. We recruited 1978 adults who had TB symptoms, were close contacts of known TB patients, or were newly diagnosed with HIV at three clinical sites. The TB-detecting AI (TB AI) scores were converted to binary using two thresholds: a high-sensitivity threshold and an exploratory threshold designed to resemble radiologist performance. Ten radiologists reviewed images for signs of TB, blinded to the reference standard. Primary analysis measured AI detection noninferiority to radiologist performance. Secondary analysis evaluated AI detection as compared with the World Health Organization (WHO) targets (90% sensitivity, 70% specificity). Both used an absolute margin of 5%. The abnormality-detecting AI (abnormality AI) was evaluated for noninferiority to a high-sensitivity target suitable for triaging (90% sensitivity, 50% specificity). Of the 1910 patients analyzed, 1827 (96%) had conclusive TB status, of which 649 (36%) were HIV positive and 192 (11%) were TB positive. The TB AI’s sensitivity and specificity were 87% and 70%, respectively, at the high-sensitivity threshold and 78% and 82%, respectively, at the balanced threshold. Radiologists’ mean sensitivity was 76% and mean specificity was 82%. At the high-sensitivity threshold, the TB AI was noninferior to average radiologist sensitivity (P<0.001) but not to average radiologist specificity (P=0.99) and was higher than the WHO target for specificity but not sensitivity. At the balanced threshold, the TB AI was comparable to radiologists. The abnormality AI’s sensitivity and specificity were 97% and 79%, respectively, with both meeting the prespecified targets. The CXR TB AI was noninferior to radiologists for active pulmonary TB triaging in a population with a high TB and HIV burden. Neither the TB AI nor the radiologists met WHO recommendations for sensitivity in the study population. AI can also be used to detect other CXR abnormalities in the same population.


  • Open Access

    Assistive AI in Lung Cancer Screening: A Retrospective Multinational Study in the United States and Japan

    by Atilla P. Kiraly, Corbin A. Cunningham, Ryan Najafi, Zaid Nabulsi, Jie Yang, Charles Lau, Joseph R. Ledsam, Wenxing Ye, Diego Ardila, Scott M. McKinney, et al.

    "Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To evaluate the impact of an artificial intelligence (AI) assistant for lung cancer screening (LCS) on multinational clinical workflows. Materials and Methods An AI assistant for LCS was evaluated on two retrospective randomized multireader multicase studies, where 627 (141 cancer positive) low-dose chest CT cases were each read twice (with and without AI assistance) by experienced thoracic radiologists (6 US-based or 6 Japan-based), resulting in a total of 7,524 interpretations. Positive cases were defined as those within two years before a pathology-confirmed lung cancer diagnosis. Negative cases were defined as those without any subsequent cancer diagnosis for at least two years and were enriched for a spectrum of diverse nodules. The studies measured the readers' level of suspicion (LoS, on a 0-100 scale), country-specific screening system scoring categories, and management recommendations. Evaluation metrics included the area under the receiver operating characteristic curve (AUC) for LoS and sensitivity and specificity of recall recommendations. Results With AI assistance, the radiologists' AUC increased by 0.023 (0.70 to 0.72, P = .02) for the US study and by 0.023 (0.93 to 0.96, P = .18) for the Japan study. Scoring system specificity for actionable findings increased 5.5% (57%-63%, P < .001) for the US study and 6.7% (23%-30%, P < .001) for the Japan study. There was no evidence of a difference in corresponding sensitivity between unassisted and AI-assisted reads for the US (67.3%-67.5%, P = .88) and Japan (98%-100%, P > .99) studies. Corresponding standalone AI AUC system performance was 0.75 95% CI [0.70-0.81] and 0.88 95%CI [0.78-0.97] for the US and Japan-based datasets, respectively. Conclusion The concurrent AI interface improved LCS specificity in both US and Japan-based reader studies, meriting further study in additional international screening environments. ©RSNA, 2024.


  • Top Cited Papers

    Enhancing the reliability and accuracy of AI-enabled diagnosis via complementarity-driven deferral to clinicians

    by Krishnamurthy (Dj) Dvijotham, Jim Winkens, Melih Barsbey, Sumedh Ghaisas, Robert Stanforth, Nick Pawlowski, Patricia Strachan, Zahra Ahmed, Shekoofeh Azizi, Yoram Bachrach, et al.

    Predictive artificial intelligence (AI) systems based on deep learning have been shown to achieve expert-level identification of diseases in multiple medical imaging settings, but can make errors in cases accurately diagnosed by clinicians and vice versa. We developed Complementarity-Driven Deferral to Clinical Workflow (CoDoC), a system that can learn to decide between the opinion of a predictive AI model and a clinical workflow. CoDoC enhances accuracy relative to clinician-only or AI-only baselines in clinical workflows that screen for breast cancer or tuberculosis (TB). For breast cancer screening, compared to double reading with arbitration in a screening program in the UK, CoDoC reduced false positives by 25% at the same false-negative rate, while achieving a 66% reduction in clinician workload. For TB triaging, compared to standalone AI and clinical workflows, CoDoC achieved a 5–15% reduction in false positives at the same false-negative rate for three of five commercially available predictive AI systems. To facilitate the deployment of CoDoC in novel futuristic clinical settings, we present results showing that CoDoC’s performance gains are sustained across several axes of variation (imaging modality, clinical setting and predictive AI system) and discuss the limitations of our evaluation and where further validation would be needed. We provide an open-source implementation to encourage further research and application.


  • Open Access

    Enhancing the reliability and accuracy of AI-enabled diagnosis via complementarity-driven deferral to clinicians (CoDoC)

    by Krishnamurthy Dvijotham, Jim Winkens, Melih Barsbey, Sumedh Ghaisas, Nick Pawlowski, Robert Stanforth, Patricia MacWilliams, Zahra Ahmed, Shekoofeh Azizi, Yoram Bachrach, et al.

    Diagnostic AI systems trained using deep learning have been shown to achieve expert-level identification of diseases in multiple medical imaging settings1,2. However, such systems are not always reliable and can fail in cases diagnosed accurately by clinicians and vice versa3. Mechanisms for leveraging this complementarity by learning to select optimally between discordant decisions of AIs and clinicians have remained largely unexplored in healthcare4, yet have the potential to achieve levels of performance that exceed that possible from either AI or clinician alone4. We develop a Complementarity-driven Deferral-to-Clinical Workflow (CoDoC) system that can learn to decide when to rely on a diagnostic AI model and when to defer to a clinician or their workflow. We show that our system is compatible with diagnostic AI models from multiple manufacturers, obtaining enhanced accuracy (sensitivity and/or specificity) relative to clinician-only or AI-only baselines in clinical workflows that screen for breast cancer or tuberculosis. For breast cancer, we demonstrate the first system that exceeds the accuracy of double-reading with arbitration (the “gold standard” of care) in a large representative UK screening program, with 25% reduction in false positives despite equivalent true-positive detection, while achieving a 66% reduction in clinical workload. In two separate US datasets, CoDoC exceeds the accuracy of single-reading by board certified radiologists and two different standalone state-of-the-art AI systems, with generalisation of this finding in different diagnostic AI manufacturers. For TB screening with chest X-rays, CoDoC improved specificity (while maintaining sensitivity) compared to standalone AI or clinicians for 3 of 5 commercially available diagnostic AI systems (5–15% reduction in false positives). Further, we show the limits of confidence score based deferral systems for medical AI, by demonstrating that no deferral strategy could have achieved significant improvement on the remaining two diagnostic AI systems. Our comprehensive assessment demonstrates that the superiority of CoDoC is sustained in multiple realistic stress tests for generalisation of medical AI tools along four axes: variation in the medical imaging modality; variation in clinical settings and human experts; different clinical deferral pathways within a given modality; and different AI softwares. Further, given the simplicity of CoDoC we believe that practitioners can easily adapt it and we provide an open-source implementation to encourage widespread further research and application.


  • Open Access

    Predicting Brain Age Using Structural Neuroimaging and Deep Learning

    by Yogatheesan Varatharajah, Sujeeth Baradwaj, Atilla Kiraly, Diego Ardila, Ravishankar Iyer, Shravya Shetty, Kai Kohlhoff

    Early detection of age-related diseases will greatly benefit from a model of the underlying biological aging process. In this paper, we develop a brain-age predictor by using structural magnetic resonance imaging (SMRI) and deep learning and evaluate the predicted brain age as a marker of brain-aging in Alzheimer's disease. Our approach does not require any domain knowledge in that it trains end-to-end on the SMRI image itself, and has been validated on real SMRI data collected from elderly subjects. We developed two different models by using convolutional neural network (CNN) based regression and bucket classification to predict brain ages from SMRI images. Our models achieved root mean squared errors (RMSE) of 5.54 and 6.44 years in predicting brain ages of healthy subjects. Further analysis showed that there is a substantial difference between the predicted brain ages of cognitively impaired and healthy subjects with similar chronological ages.


  • Parsing of the Lungs and Airways

    by A.P. Kiraly, B.L. Odry, C.L. Novak

  • Automated CT Scoring of Airway Diseases

    by Benjamin L. Odry, Atilla P. Kiraly, Myrna C.B. Godoy, Jane Ko, David P. Naidich, Carol L. Novak, Jean-Francois Lerallut


  • A novel multipurpose tree and path matching algorithm with application to airway trees

    by Jens N Kaftan, Atilla Peter Kiraly, David P Naidich, Carol L Novak

    Tree matching methods have numerous applications in medical imaging, including registration, anatomical labeling, segmentation, and navigation of structures such as vessels and airway trees. Typical methods for tree matching rely on conventional graph matching techniques and therefore suffer potential limitations such as sensitivity to the accuracy of the extracted tree structures, as well as dependence on the initial alignment. We present a novel path-based tree matching framework independent of graph matching. It is based on a point-by-point feature comparison of complete paths rather than branch points, and consequently is relatively unaffected by spurious airways and/or missing branches. A matching matrix is used to enforce one-to-one matching. Moreover our method can reliably match irregular tree structures, resulting from imperfect segmentation and centerline extraction. Also reflecting the nature of these features, our method does not require a precise alignment or registration of tree structures. To test our method we used two thoracic CT scans from each of ten patients, with a median inter-scan interval of 3 months (range 0.5 to 10 months). The bronchial tree structure was automatically extracted from each scan and a ground truth of matching paths was established between each pair of tree structures. Overall 87% of 702 airway paths (average 35.1 per patient matched both ways) were correctly matched using this technique. Based on this success we also present preliminary results of airway-to-artery matching using our proposed methodology.